Instruction Manual
Installer Menu
Revision E Display and Menu Options 3-27
22
0 = Normally Open Edge
1 = Normally Closed
The default setting is edge sensor with Normally Open
(NO) output. The optional setting of 1 requires an (NC)
output.
EDGE
COM
23
0 = Disable Free Exit
1 = Disable Close Timer
Configures the BLOCK EXIT input to disable either the
Free Exit Detector function or, alternately, the Timer To
Close function. The default setting disables the free exit
detector.
Note: The free exit is disabled when the gate is at its closed
limit. If the closed limit is not tripped, the free exit
continues to work normally.
BLOCK EXIT
COM
24
0 = Pause closing only
1 = Enable reversing to
open
The default is for full reversal when the Outside
Obstruction Loop is triggered. A setting of 0 causes the gate
to only pause when triggered. Gate closure begins as soon as
the loop is clear again.
OUTSIDE OBS LOOP
COM
25
0 = Pause closing only
1 = Enable reversing to
open
The default is for full reversal when the Inside Obstruction
Loop is triggered. A setting of 0 causes the gate to only
pause when triggered. Closure begins as soon as the loop is
clear again.
INSIDE OBS LOOP
COM
Table 3-2. Smart DC Controller - Installer Menu Functions (Continued)
Ref.
No.
*
Installer Menu
Setting Options
(
Bold = Factory Settings
)
Tasks and Explanations
Associated
DC Controller
Connections
Display
GC 0 NO CONTACT
GATE EDGE OUTPUT
DT 0 FREE EXIT
DISABLE FUNCTION
OR 1 REVERSE
OUTSIDE OBS LOOP
IR 1 REVERSE
INSIDE OBS LOOP