Instruction Manual

Installer Menu
3-26 SwingSmart DC Installation and Reference Manual Revision E
17
0 = Close eye stops only
1 = 2s reverse to open
The default setting is non-reversal if the close photo eye is
triggered. A setting of 1 causes the gate to reverse and travel
open for two seconds if triggered while closing.
EYE OPEN
EYE COM
18
0 = Open eye stops only
1 = 2s reverse to close
The default setting is non-reversal if the open photo eye is
triggered. A setting of 1 causes the gate to reverse travel and
close for two seconds if triggered while opening.
EYE CLOSE
EYE COM
19
0 = Edge reverses full open
1 = 2s reversal only
The default setting is a full-open reversal if the gate edge is
triggered while closing. The optional setting of 1 causes the
gate to reverse for 2 seconds if triggered while closing.
EDGE
COM
20
0 = IES reverses full open
1 = 2 second reversal only
The default setting is a 2-second duration reversal if the
inherent sensor is triggered. The optional setting of 0 will
cause the gate to reopen fully if triggered while closing.
N/A
21
0 = Normal Open PE output
1 = Normal Closed
(supervised)
The default setting is photo eyes with Normally Open
outputs. The optional setting 1 requires a Normally Closed
(NC) output which requires that both a photo EYE OPEN
and a photo EYE CLOSE are connected. If set for NC, the
connection is also supervised and any open or short circuit
fault will generate a FAULT 2 alert which requires a STOP
button reset to re-enable any function if triggered.
Photo eye connections:
EYE OPEN
EYE CLOSE
EYE COM
+24V
Table 3-2. Smart DC Controller - Installer Menu Functions (Continued)
Ref.
No.
*
Installer Menu
Setting Options
(
Bold = Factory Settings
)
Tasks and Explanations
Associated
DC Controller
Connections
Display
EC 0 (STOP ONLY)
EYE CLOSE LOGIC
EO 0 (STOP ONLY)
EYE OPEN LOGIC
GR 0 (FULL OPEN)
GATE EDGE LOGIC
SR 0 (FULL OPEN)
IES SENSOR LOGIC
PC 0 NO CONTACT
PHOTO EYE OUTPUT