Instruction Manual
Installer Menu
Revision E Display and Menu Options 3-23
5
5
1 through 10
1 = slowest speed
10 = fastest speed
Designate how quickly the gate opens. The range 1 through
10 varies the speed of the motor and the gate opening speed
increases as you go up the number scale. A setting of 1
slows the gate travel to approximately 15 seconds. A setting
of 10 speeds up gate travel to approximately 10 seconds.
See Adjusting the Gate Speed.
(N/A)
6
5
1 through 10
1 = slowest speed
10 = fastest speed
Designate how quickly the gate closes. The range 1 through
10 varies the speed of the motor and the gate closing speed
increases as you go up the number scale. A setting of 1
slows the gate travel to approximately 15 seconds. A setting
of 10 speeds up gate travel to approximately 10 seconds.
See Adjusting the Gate Speed.
(N/A)
7
0 = user settings
1 = reload factory settings
Globally restores all menu settings back to new operator
status. Select setting 1 to return the operator to factory
defaults.
Note: If factory defaults are restored, the UL usage class,
handing, gate weight and length and any other
modified menu settings will need to be configured
again.
(N/A)
8
0 = solo operator
1 = Slave unit
2 = Master unit
3 = Sally Port A
4 = Sally Port B
Programs and establishes communication protocols when
wiring two operators as dual gates in a Master/Slave or Sally
Port configuration. This menu item appears if the
sequenced gate (SG) is set at 0 (solo operator). When you
assign one unit as the Master (or Sally Port A), you must
configure the other as Slave (or Sally Port B) through the
Installer Menu. See Master and Slave Menu Setup.
Note: Use the most up-to-date version of S.T.A.R.T. and
make sure both operator’s have the same software
version loaded on the SDC. Press the RESET
button to display the version of software on your
operator.
3-wire shielded cable to
DUAL GATE input
terminals. Connect Dual
Gate COM (Gate 1) to
Dual Gate COM (Gate 2).
Pair wires:
A - A, COM - COM,
and B - B
Table 3-2. Smart DC Controller - Installer Menu Functions (Continued)
Ref.
No.
*
Installer Menu
Setting Options
(
Bold = Factory Settings
)
Tasks and Explanations
Associated
DC Controller
Connections
Display
SH 0
GATE HANDING
OS 5
OPEN SPEED
SH 0
GATE HANDING
CS 5
CLOSE SPEED
FD 0 (OFF)
FACTORY DEFAULTS
DUAL GATE
<MASTER>
DG 0 (OFF)
DUAL GATE