Instruction Manual

Installer Menu
3-22 SwingSmart DC Installation and Reference Manual Revision E
Table 3-2. Smart DC Controller - Installer Menu Functions
Ref.
No.
*
Installer Menu
Setting Options
(
Bold = Factory Settings
)
Tasks and Explanations
Associated
DC Controller
Connections
Display
1
0 = Gate disabled
1 =
Residential 1 to 4 units
2 = Comm./public access
3 = Light industrial
4 = Industrial secure
Assign the operator’s Usage Class designation per UL 325
standards. See Identifying Gate Operator Category and Usage
Class. The installer must designate a usage class before the
operator will function. See Configuring the Setup Menu.
Not applicable (N/A)
2
0 = Gate disabled
R = Right hand
L = Left hand
The handing determines which way the gate opens as you
view it from the operator side. See Adjusting the Limit
Switches. The installer must designate a left or right
handing before the operator will function. See Configuring
the Setup Menu.
(N/A)
3
0 = Gate disabled
1 = 0 to 300lbs.
2 = 301 to 600lbs.
3 = 601 to 800lbs.
4 = 800 to 1300lbs.
Select the gate’s weight range in pounds. The installer must
designate the gate’s weight before the operator will
function. See Configuring the Setup Menu. Designating the
correct gate weight allows the operator to determine the
appropriate acceleration and deceleration rates.
(N/A)
4
0 = Gate disabled
1 = 0 to 8 feet
2 = 8 to 12 feet
3 = 12 to 16 feet
4 = 16 to 20 feet
Select the gates length in feet. The installer must designate
the gates length before the operator will function. See
Configuring the Setup Menu. Designating the correct gate
length allows the operator to determine the appropriate
acceleration and deceleration rates.
(N/A)
UC 0
USAGE CLASS
SH 0
GATE HANDING
SH 0
GATE HANDING
WT 0
GATE WEIGHT (LB)
SH 0
GATE HANDING
LN 0
GATE LENGTH (FT)