Instruction Manual
User Menu
Revision E Display and Menu Options 3-15
10
0 = Display
1 = Set Clock
The Smart DC Controller is equipped with a 24 hour 365
day clock; thus events of significance are logged and
stamped with the time and date. This feature is useful to
read historical operation data, which can be accessed with a
computer via the USB or RS232 port. To set or adjust the
hour, minute, day or month, see Setting the Time and Date.
(N/A)
11
5
0 through 9
Under some extreme high or low temperature conditions, it
may be necessary to adjust the contrast of the LCD display.
The display is adjustable from 0-9 with a factory default
setting of 5.
(N/A)
12
0 = off (standard)
1 = on (detailed)
Set this item to 1 to record all gate operator open and close
events, in addition to the normal alert, fault and error logs.
This parameter automatically resets to the default 0 (off)
after 24 hours, which is useful when experiencing
intermittent problems.
Set to 0, the DC Controller logs pertinent gate operator
events such as faults, errors, or menu manipulation.
USB or RS232 cable and
laptop computer with
HySecurity’s free S.T.A.R.T.
software is required to read
the log file.
Tabl e No te s:
The following conditions apply to the indicated reference-numbered menu selections:
2 & 3 For gate operators using Type D entrapment protection, an automatic closing device (such as a timer, loop sensor, or similar device) shall not be employed. For additional
information, refer to Choosing Secondary Entrapment Protection.
Table 3-1. Smart DC Controller - User Menu Functions
Ref.
No.
*
User Menu
Setting Options
(
Bold = Factory Settings
)
Menu Tasks and Explanations
Associated
DC Controller
Connections
Display
CL 0
SET CLOCK
LD 5
LCD CONTRAST
DS 0 (OFF)
DIAGNOSTIC LOGS