Instruction Manual

User Menu
3-14 SwingSmart DC Installation and Reference Manual Revision E
6
0 = off
1 = on
2 = on
Controls the warn-before-operate buzzer and can be
configured three ways:
Set to 1: Buzzer beeps for 3 seconds before gate motion
begins and continues through entire gate travel.
Set to 2: Buzzer beeps for 3 seconds before gate motion
begins and continues for 2 seconds of gate travel.
Set to 0: Buzzer is disabled. Set at 0 the buzzer will still beep
when alerts, faults, errors, or entrapment are detected.
WARNING: Do NOT cut the wires to the buzzer or
unplug it as the operator will not be in compliance with
UL 325. Failure to comply may result in serious injury or
death.
(N/A)
7
0 = off
1 = on
Intended for highly secure facilities.
Set to 1, the operator sounds the 3-second “warn before
operate” buzzer alarm, and then initiates a closure if the
gate is forced open and the closed limit switch disengages.
The motor restarts to secure the gate. If the gate does not
fully close within 4 seconds, the motor turns off and the
alert buzzer sounds for 30 seconds. The display shows
ALERT 1 - FORCED OPEN.
(N/A)
8
0 = off
1 = on
Set to 1, the operator sounds the 3-second “warn before
operate” buzzer alarm and initiates an open command if the
gate is forced, or drifts, off the open limit switch. The
motor starts to reopen the gate. The motor runs for a
maximum of 4 seconds and, if the gate is not fully open at
the end of this period, the buzzer sounds for 10 seconds.
The display shows ALERT 2 - DRIFT CLOSED
(N/A)
9
0 = off
1 = on
When set to 1, the operator serves as an aide in photo-eye
transmitter/receiver alignment. The buzzer chirps once
when the emitter and receiver are not aligned. When the
emitter and receiver are aligned, the buzzer chirps twice. If
they go out of alignment again, the buzzer will chirp once.
The Alignment Mode is reset with a close-limit input or
reset input.
EYE OPEN
EYE CLOSE
EYE COM
Table 3-1. Smart DC Controller - User Menu Functions
Ref.
No.
*
User Menu
Setting Options
(
Bold = Factory Settings
)
Menu Tasks and Explanations
Associated
DC Controller
Connections
Display
BF 2 (ON 2 SEC)
WARN BEFORE OPER
FA 0 (OFF)
FORCE OPEN ALERT
DA 0 (OFF)
DRIFT CLOSE ALERT
PE 0 (OFF)
PHOTO EYE ALIGN