7. Follow the step-by-step instructions to complete the installation.*
8. When the download is complete, log out of the HySecurity website. Shortcuts for the S.T.A.R.T. and SDC
History Logs appear on your laptop’s desktop.
*NOTE: Conrm you have administrative rights by clicking the following on your computer screen:
Windows start ->Control Panel ->User Accounts ->User Accounts. See if your name appears as an administrator.
If you are the only user of a computer, you are by default the administrator. If not, you may need to consult with
your company’s system administrator prior to downloading the HySecurity START program.
softWare maIntenanCe
The software on the SDC board is periodically being enhanced with new features that create an easier install and
improve the on board diagnostic tools. Be sure to check the HySecurity website for the latest version of software
and operator code before heading out for eld maintenance.
eleCtrICal Controls
CAUTION
Before servicing, turn off all power switches.
No routine maintenance is needed for the electrical system or controls. If the environment is very sandy or dusty,
or has many insects, be certain to seal all holes in the electrical enclosure. Blow the dust out of the electric panel
with compressed air. Use the “Troubleshooting Codes” on page 5-2 to assess and x error, alert, and fault
codes. If it is necessary to call a distributor for assistance, be sure to have your model and serial number ready.
Other helpful information includes the name of the job, approximate date of installation, software version, and
the service record of the operator, especially if any work has been done recently.
Clock Battery Replacement
A lithium coin battery supports the clock, so the date and time is retained even
when the main power is turned off. Replace the battery about every two years (or
as needed) with a DL 2025, DL 2032, or CR 2025, or CR 2032 battery.
Fuse Replacement
A 35A fuse is located next to the 24VDC power supply inputs on the SDC. It
requires no maintenance, but if it were blown due to a power surge or other unusual circumstance, it must be
swapped out with a new fuse. The symptoms of a blown fuse appear as a control system malfunction (i.e. all
control systems may not work properly).