3-10 D0536 Rev. B StrongArmPark DC: Programming & Operations Manual www.hysecurity.com
Installer Menu Setting Options Menu Tasks & Explanations SDC Wire
Connections
RL20CLOSELIMI
Relay 2 Logic
0 = Disabled Relay2conguresthefunctionoftheUser2
output relay, which is an electronic relay with the
capacity for switching a DC load only.
NOTE:IntheStrongArmParkDC,itisrecom-
mended to use the User 2 Relay for connection
totheLEDarmlighting.
COM
User 2 Relay
RL30DISABLED
thru
RL100DISABLED
Relay Logic
0 = Disabled
1to38available
SimilartoRelay1Logic. COM
User3through10
Relay
TL2(45SECS)
OpenTimeAlert
2 = 45 second delay
0=0sdelay
1=15s
3=75s
4=105s
5=135s
Thismenuitemonlyappearsifthe#8User
Relay function has been selected. It adjusts the
time delay before activation of the User Relay
function.
User Relay
LT3(75SECS)
LoiteringAlert
3 = 75 second delay
0=0sdelay
1=15s
2=45s
4=105s
5=135s
Thismenuitemonlyappearsifthe#13User
Relay function has been selected. It adjusts the
time delay before activation of the User Relay.
User Relay
SA0(OFF)
SDCAddress
0 = No network
1to99=Network“drop”address
Sets the system address for network
communication:0=nonetworkcommunication
1-99setsindividualpolingaddresses.
SeePDSETPASSWORDin“UserMenu:Table
1.”onpage3-4.
RS-485. Involves ad-
ditionalhardware&
software.
ELD0RUNMODE
ExitLoopSet
0 = Run mode
1=Showfrequency
2=Showcalllevel0-7
3=SetFrequency
ControlstheHY-5AFreeExitloopdetector. HY-5A
ILD0RUNMODE
InArmLoopSet
0 = Run mode
1=Showfrequency
2=Showcalllevel0-7
3=SetFrequency
ControlstheHY-5AInsideObstructionLoop
(InnerArmingLoop)detector.
HY-5A
OLD0RUNMODE
OutArmLoopSet
0 = Run mode
1=Showfrequency
2=Showcalllevel0-7
3=SetFrequency
ControlstheHY-5AOutsideObstructionLoop
(OuterArmingLoop)detector.
HY-5A
CLD0RUNMODE
Center Loop Set
0 = Run mode
1=Showfrequency
2=Showcalllevel0-7
3=SetFrequency
ControlstheHY-5ACenterLoopdetector. HY-5A