Owner manual
www.hysecurity.com Display Menu D0536 Rev. B 3-9
Installer Menu Setting Options Menu Tasks & Explanations SDC Wire
Connections
OR1REVERSE
OuterArmLoop
0=Pauseclosingonly
1 = Enable reversing to open
2=Ignoreandcontinueclosing
The default is for full reversal when the Inner
ArmingLoopistriggered.Asettingof0causes
the barrier arm to only pause when triggered.
Closure begins as soon as the loop is clear again.
Asettingof2isprovidedforthemostsecure
facilities where it is essential that the loop trigger
is completely ignored and the barrier arm contin-
ues closing without pause or reversal.
OUT OBS LOOP
(OUTERARMING)
COM or connection
toHY-5Adetector
IR1REVERSE
InnerArmLoop
0=Pauseclosingonly
1 = Enable reversing to open
2=Ignoreandcontinueclosing
The default is for full reversal when the Inner
ArmingLoopistriggered.Asettingof0causes
the barrier arm to only pause when triggered.
Closure begins as soon as the loop is clear again.
Asettingof2isprovidedforthemostsecure
facilities where it is essential that the loop trigger
is completely ignored and the barrier arm contin-
ues closing without pause or reversal.
IN OBS LOOP
(INNERARMING)
COM or connection
toHY-5Adetector
DL1STANDARD
Detector Logic
1 = Standard
2=QuickClose
Conguresforfasterclosure.Thisselection
determines whether the close timer begins to
count after vehicles have departed the detector
loops or whether the close timer will count down
while the loops are occupied.
Thedefaultsetting1causestheCloseTimerto
startwhentheCenterLoopisclear.Asettingof
2 causes the Close Timer to start when the open
limit switch trips.
Center Loop
COM or connection
toHY-5Adetector
CR0REVERSE
Center Loop
0 = Reopen if center loop triggers
1=Pauseonly
The default allows the barrier arm to reopen if
the Center Loop detector is triggered during
closureofthebarrierarm.Asettingof1causes
the barrier arm to only pause when triggered.
Closure begins as soon as the loop is clear again.
Center Loop
COM or connection
toHY-5Adetector
CB 0 (OFF)
CLDDisableELD
0 = Normal operation of Free Exit
1=DisableFreeExit
Setting1allowsanCLDinputtodisabletheFree
ExitDetector(ELD)untilthebarrierarmisfully
closed.Usedinbi-directionaltrafcsituations.
Center Loop
COM or connection
toHY-5Adetector
CP 0 (OFF)
CLD Counts PBO
0 = Immediate closure
1=Providesaddt’lopentime
The default allows the Center Loop Detector
when triggered and released, to close the barrier
armimmediately.Theoptionalsettingof1des-
ignates that the Smart DC Controller remember
an additional open command if the open input
is activated a second time while the barrier arm
remains open. (For example, to prevent a vehicle
from being stranded).
Center Loop
COM or connection
toHY-5Adetector
EB0(OFF)
ELDBackoff
0 = Normal operation of Free Exit
1=Backoffclosefunction
The default allows normal latch open operation
oftheFreeExitdetector.Theoptionalsettingof
1,createsanautomaticclosefunctionifavehicle
triggersandthenbacksofftheFreeExitLoop
detector.
FreeExitLoop
COM or connection
toHY-5Adetector
RL10DISABLED
Relay1Logic
0 = Disabled
1to38available
ConguresthefunctionoftheUser1output
relay.IthasthecapacitytoswitchbothACand
DC loads and can be used for high voltage and/
or high current loads. Connect devices directly to
the top of the relay: COM and either NO and/or
NC contacts.
Multiple logic function options exist. See “User
Relays - Programming Procedure” on page 6-8.
COM
User1Relay