Installer Menu Setting Options Menu Tasks & Explanations SDC Wire
Connections
CH0(AC)
Charger Type
0 = AC powered charger
1=Solarpoweredcharger
Assignschargertype.
If a solar-powered unit is ordered and delivered
factory-ready, this menu will not appear.
NOTE:MenuitemdoesnotappearonanAC-
powered operator.
BT0(STANDARD)
Battery Type
0 = standard 8Ah
1=extended(50Ah)
2=maximum(110Ah)
Assignthebatterytypeusedbytheoperator.
Smaller batteries are charged with less current
to avoid overheating and larger batteries are
charged with more current to supply a more
rapid charge.
Extendedand
maximum batter-
ies require separate
housing and wiring.
FO 0 (OFF)
Fire Dept Open
0 = disabled
1=enabled
Provides the Fire Dept. Open input and allows
a button to activate the emergency open when
connectedto+24VDC.Whensetto1,theopen
signal received by the operator overrides all pho-
toelectric eyes and edge sensors, and opens the
barrier arm. Pressing the Reset or Open button is
required before the barrier arm can be closed.
+24V
Fire Dept Open
EC0STOPONLY
EyeCloseLogic
0 = Close eye stops only
1=Reversetofullopenwithbarrier
gates (2 second reverse to open on
swing, slide, or vertical gates)
The default setting is non-reversal if the close
photoeyeistriggered.Asettingof1causesthe
barrier arm to reverse and travel full open if trig-
gered while closing.
EYEClose
EYECOM
(Inputs#14or#15)
LC0(0.0SECS)
LEAFDELAYCLOSE
0 = none
1 through 20
For example:
1 = ½ second
4 = 2 seconds
20 = 10 seconds
Delays gate closure. This menu option appears
if the gate operator is designated as a dual
gate system (Master/Second, for example).
Availablesettingsare1to20.Eachincrement
adds ½ second, to a maximum of 10 seconds
time delay, before the operator activates when
commanded to close.
DUALGATEinputs
on both operators
LC0(0.0SECS)
LEAFDELAYOPEN
0 = none
1 through 20
For example:
1 = ½ second
4 = 2 seconds
20 = 10 seconds
Delays gate opening. This menu option appears
if the gate operator is designated as a dual gate
system(Master/Second,forexample).Available
settingsare1to20.Eachincrementadds½
second (with a maximum of 10 seconds) time
delay following a command to open before the
operator activates.
DUALGATEinputs
on both operators
PC0NOCONTACT
PhotoEyeOutput
0 = Normal Open PE output
1 = Normal Closed (supervised)
The default setting is for photo eyes with Nor-
mally Close outputs for Crash Operators only.
When set for NC, the connection is supervised
and any open or short circuit fault will generate a
FAULT2alertwhichrequiresaStoporResetbut-
tonpresstoclearandenter.AllotherHySecurity
operators are factory set for normal open (a set-
tingofzero).
EYEClose
EYECOM
4 wires total:
COM/+24
COM/PHOTOEYE
CLOSE
GC0NOCONTACT
GateEyeOutput
0 = Normally Open Edge
1=NormallyClosed
The default setting is edge sensor with Normally
Open(NO)output.Theoptionalsettingof1
requires an (NC) output.
COM
EDGE
DT0FREEEXIT
Disable Function
0 = Disable Free Exit
1=DisableCloseTimer
CongurestheBLOCKEXITinputtodisable
eithertheFreeExitDetectorfunctionor,alter-
nately, the Timer To Close function. The default
setting disables the free exit detector.
NOTE: The free exit is disabled when the gate
is at its closed limit. If the closed limit is not
tripped, the free exit continues to work normally.
COM
BLOCKEXIT