SPX-7400 Series Operations Manual Suprex® Reader Extender - Fiber Optic Interface SPX-7400 shown with EXP-2000 SPX-7400_MAN_082112
Suprex® SPX-7400 Series This manual covers the operation and setup of the Cypress Suprex® Fiber Optic SPX-7400 series units. Overview: The SPX-7400 series of Fiber Optic solutions provides a bridge from Card Readers with gates or door hardware to most access control manufacturers panels. The SPX or Suprex® products include both the remote ( Door/Gate ) unit and the central ( AC Panel ) unit.
External connections and DIP Switch Settings 1 - 8 to 16 VDC In 2 - Ground SPX-7400 Central Status LED 1- Relay 4 N.O. 2- Relay 4 Com 3 - Relay 4 N.C. 4 - Relay 3 N.O. 5 - Relay 3 Com 6 - Relay 3 N.C. 7 - Ground 8 - Aux out 9 - R2 in 10 - R1 in 1 - exp (+) 2 - exp (-) 3 - +5 VDC out 4 - Prog Res 4 5 - Prog Res 3 6 - LED In 7 - D1/Data out 8 - D0/Clk out 1 - 8 to 16 VDC In 2 - Ground SPX-7400 Remote Status LED 1- Relay 2 N.O. 2- Relay 2 Com 3 - Relay 2 N.C. 4 - Relay 1 N.O.
Quick Reference For Typical Connections SPX-7400 Series Central DC Power Supply +8 to +16 VDC Ground Diagnostic LED Access Control Panel R1 Input Controls Strike on Remote LED In D1/Data Out D0/Clock Out R1 IN See page 10 for other strike control options SPX-7400 Series Remote DC Power Supply +8 to +16 VDC Ground Diagnostic LED R1 N.O. R1 Com R1 N.C.
Fiber Optic Connections Fiber Optic Interface SPX-7400 Central TX RX Fiber Optic Interface SPX-7400 Remote TX RX
Temperature Rating vs Voltage Derating Curve 80 55 Ambient Temperature (Degrees Celsius) 35 -40 8 10 12 14 16 Supply Voltage Temperature/Voltage de-rating curve The Suprex® units should be operated with a filtered 12 Volt nominal DC supply. Any voltage between 8 and 16 volts can be utilized by following the temperature /voltage derating curve. Voltage should not exceed 16 VDC under normal operating conditions.
Cypress Suprex® SPX-7400 Enclosure Dimensions 4.45 3.15 0.80 3.08 0.80 ø0.20 X 4 2.00 1.
Cypress Suprex® SPX-7400 Series - Setup and Pre-installation Bench Testing: Before installing the units in the field they should be assembled and tested at a convenient “Bench top” location. This will make it easier to verify / change settings and check operation when both units are visible at the same time. It is also a chance to become familiar with the system if this is the first time using the Suprex® system.
Cypress Suprex® SPX-7400 Series - Status Indicators LED Diagnostic Indicator: The LED Diagnostic indicator provides information on the operational status of the unit. If the units are not communicating, viewing the diagnostic indicator LED’s may help to determine the nature of the problem. When the Suprex® units are operating correctly and have a valid communication channel between the Remote and Central units, the Diagnostic indicators on each unit will flash green rapidly (2-3 flashed per second).
Cypress Suprex® F.O. Series - Door Strike and LED I/O Note: The LED and Door Strike operation of the FO Suprex® differs from previous Suprex® version To activate the relay on the Remote unit, connect as shown below. These connections can be used to allow the Remote relay to operate a DOOR STRIKE, GATE, or other locking hardware. Refer to following pages in this document for details of each I/O operation and connection. There are two relays available for accessory outputs at the Remote end.
Cypress Suprex® F.O. Series - Door Strike and LED I/O The Cypress SPX-7400 provides additional data channels to support access control hardware such as door strikes, tamper alarms, request to exit status, etc. These signals are sent to and from the Remote and Central units without the need to run additional wiring. The accessory control I/O use active low inputs. When the inputs are floating (nothing connected) the associated output will be set to a high level.
Cypress Suprex® F.O. Series - Relay Controls Suprex® Central Suprex® Central Relay 2 IN Input Signal Relay 1 IN Input Signal Red arrow denotes direction of command signal Relay 2 N.O. Relay 2 Com Relay 2 N.C. Suprex® Remote Contact Outputs Relay 1 N.O. Relay 1 Com Relay 1 N.C.
Cypress Suprex® F.O. Series - Relay Controls Relay 4 N.O. Relay 4 Com Relay 4 N.C. Suprex® Central Relay 3 N.O. Relay 3 Com Relay 3 N.C. Suprex® Central Contact Outputs Contact Outputs Red arrow denotes direction of command signal Suprex® Remote Suprex® Remote Relay 4 IN Relay 3 IN Input Signal (5Volts DC Maximum) Input Signal (5Volts DC Maximum) Relay 3 functions as an Alarm relay and monitors the condition of the communication link between the Central and Remote units.
SPX-XXXX Application Note Using Supervised Contacts with the SPX-series Extenders Applies to the following products: SPX-5501, SPX-5601, SPX-5521, SPX-5621, SPX-7400, SPX-7410, SPX-7200, SPX-7500, All RIM series products. This application note describes the connections necessary to convey supervised contact status over a Suprex® communication link. The configurations described in this app note should apply to most panels that utilize supervised contacts.
SPX-7400 Setup - Using Expansion Modules Before using EXP-2000 Expansion modules with the SPX-7400 system, it will be necessary to perform a short configuration process. This process determines if the 7400 will utilize expansion modules, and if so, how many will be used with the system. Each SPX-7400 link can support up to 7 expansion modules. SPX-7400 units are shipped in the factory default condition. Factory default units will be setup to function as SPX-7400 units without expansion modules.
Cypress Suprex® LYNK Fiber Optic Solution Door / Parking Gate EXP-2000C (8) SPX-74X0R (1) ACS EXP-2000C (4) EXP-2000R (2) EXP-2000C (3) ACS EXP-2000C (2) EXP-2000R (3) EXP-2000R (4) EXP-2000R (8) SPX-74X0C (1) Card Reader Wiegand Data Fiberoptic Link RS-485 Link - Multi-drop
Cypress Suprex® Series - Wiegand Expansion Module Panel “Central” interface DC Power Supply +8 to +16 VDC Ground EXP(+) EXP(-) Access Control Panel LED In D1/Data Out D0/Clock Out 8 to 16 VDC In Ground 485(+) 485(-) +5 VDC Out Prog Res 4 Prog Res 3 LED Input D1/Data Out D0/Clock Out * EXP-2000 Central Unit SPX-XXXX Central R1 IN RLY4 N.O. RLY4 Com RLY4 N.C. RLY3 N.O. RLY3 Com RLY3 N.C.
Cypress Suprex® Series - Wiegand Expansion Module Reader/Door “Remote” interface DC Power Supply 8 to 16 VDC In Ground EXP (+) EXP (-) SPX-XXXX Remote R1 N.O. R1 Com R1 N.C. LED Out D1/Data In D0/Clock In Card Reader 8 to 16 VDC In Ground 485(+) 485(-) +5 VDC Out RLY4 Input (5V) RLY3 Input (5V) LED Output D1/Data Input D0/CLK Input * EXP-2000 Remote Unit RLY2 N.O. RLY2 Com RLY2 N.C. RLY1 N.O. RLY1 Com RLY1 N.C.