Manual
Using A Solar Powered Operator
2-10 SlideSmart Installation and Reference Manual Revision B
Understanding Gate Activity based on Solar Zones
NOTE
Map Legend
The chart is based on a 20 Watt (24VDC) solar panel system
with SlideSmart powering a 30 foot (9 m), 1000 lbs, 1ft/s ga te
with the following peripherals attached:
One low current multi-code radio receiver
Two HY-5A vehicle detectors
The number of amps that the peripherals draw coupled with the gate travel
occurring throughout the night determines the battery capacity required.
The number of amps that the peripherals draw coupled with the gate travel during
the day, determines the solar panel size needed.
NOTE: HySecurity provide s a 50Ah battery option for sites where high gate travel and
inclement weather are an issue. For sites of this nature, consider a 40W system. A
40W system doubles the feet of gate trave/day that is shown in the chart above.
Figure 2-7.