CO NT RO LL ER GL MODEL SL575 HEAVY DUTY SLIDE GATE OPERATOR 2 YEAR WARRANTY Serial # ________________________ (located on electrical box cover) Installation Date __________________ MODEL SL575 IS FOR VEHICULAR PASSAGE GATES ONLY AND IS NOT INTENDED FOR PEDESTRIAN PASSAGE GATE USE BO AR D
TABLE OF CONTENTS OPERATOR SPECIFICATIONS • These instructions are intended to highlight certain safety related issues. These instructions are not intended to be comprehensive. Because each application is unique, it is the responsibility of the purchaser, designer, installer and end user to ensure that the total gate system is safe for its intended use. Carton Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Operator Dimensions & Horsepower Chart . . . . . . . . . . . .
O P E R AT O R D I M E N S I O N S A N D H O R S E P O W E R C H A R T MODEL SL575 • 1/2 HP Motor Maximum Cycle Rate - 22 cycles per hour (At Maximum Gate Weight) Maximum Gate Speed – 10"/sec. (25.4 cm/sec.) Maximum Gate Weight – 1200 lbs. (544.3 kg) Maximum Cantilever Gate Width – 25 ft. (7.6 m) Maximum Overhead Roller Gate Width – 40 ft. (12.2 m) Maximum V-Track Gate Width – 30 ft. (9.1 m) • 1 HP Motor Maximum Cycle Rate - 18 cycles per hour (At Maximum Gate Weight) Maximum Gate Speed – 10"/sec. (25.
U L 3 2 5 M O D E L C L A S S I F I C AT I O N S CLASS I – RESIDENTIAL VEHICULAR GATE OPERATOR A vehicular gate operator (or system) intended for use in a home of one-to four single family dwellings, or a garage or parking area associated therewith.
O P E R AT O R WA R N I N G S SAFETY INSTALLATION INFORMATION 1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component. Each gate system is specifically designed for an individual application. 2. Gate operating system designers, installers and users must take into account the possible hazards associated with each individual application.
S U G G E S T E D E N T R A P M E N T P R O T E C T I O N D E V I C E L O C AT I O N S GATE SYSTEM (MASTER/SECOND SLIDE GATE) Open Edge Gate 1 Photo Eyes for Open Cycle Close Edge Run Twisted Wire from Loop to Operator STREET Seal Loops Interrupt (Safety) Loop Gate 2 1-1/2" (37 mm) 4' (1.2 m) Typical Open Edge 4' (1.2 m) Typical 6' (1.8 m) Loop Wire Layer Interrupt (Safety) Loop 1/4" (6 mm) or Larger Depending on Loop Wire Size COMPLEX OR PARKING LOT 12' (3.7 m) 4' (1.
SAFETY PRECAUTIONS FOR OPEN ROLLER GATES Gate Edge on Rear of Gate for Open Direction WARNING • Injuries occur when people get their hands or feet caught between the top or bottom of the gate and the gate roller. These potential pinch-points should be guarded against at ALL times. Enclosed style gate tracks are available for refitting of these rollers from many fence suppliers. Also, roller guards are available for installing over the rollers.
WIRING WARNING G WARNING MENT N To reduce the risk of SEVERE INJURY or DEATH: • ANY maintenance to the operator or in the area near the operator MUST not be performed until disconnecting the electrical power and locking-out the power via the operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service. • Disconnecting power at the fuse box BEFORE proceeding.
I N S TA L L AT I O N PAD MOUNTING Figure 1 RETRO-FIT INSTALLATION The operator is shipped from the factory with the lower mounting angles configured out (Figure 1). If you have pad constrictions, either angle can be unbolted and reversed to ‘angle in’. NOTE: If you are replacing an SL540/SL570 and wish to use the same pad mounting hardware, the gate side mounting angle must be installed angle in. Angle In NEW INSTALLATION Concrete Pad Preparation: 1. Lay out concrete pad. (Figure 2). 2.
POST MOUNTING RETRO-FIT INSTALLATION The operators come from the factory configured to mount to an inside the frame post mount dimension of 26" (outside to outside of posts). The frame comes slotted to accommodate posts 24-1/8" to 26", outside to outside (Figure 1). NOTE: If you are replacing a SL540/SL570, the frame will require adjustment to 24 1/8". Figure 1 NEW INSTALLATION 1. Locate and anchor two posts made of 3" (7.6 cm) outer diameter heavy walled pipe.
INSTALL GATE BRACKET & DRIVE CHAIN WARNING WARNING Figure 1 CAUTION WARNING “Outside” Gate To prevent damage to the operator or gate, DO NOT drive the limit (nuts) actuators on the shaft past their normal positions. “Inside” 1. Mount gate brackets to the vertical front and rear posts of the gate (Figure 1). 2. Remove the operator cover. 3. Locate and engage the manual disconnect and lock it in place (refer to page 14). 4.
AVAILABLE CONDUIT ACCESS FOR THE ELECTRICAL BOX The accessory tray is equipped with several 1-1/2" pass though holes as well as 3/4" and 1" knock outs for conduit connectors. The electrical box is equipped with 3/4" and 1" knock outs for conduit connectors. ON/OFF SWITCH POWER WIRING NOTE: Before running power wiring refer to wiring specifications on page 8 for correct wire gauges. Secure all electrical power connections inside the disconnect switch electrical box.
ADJUSTMENT LIMIT SWITCH ADJUSTMENT WARNING NOTE: Make sure the limit nuts are positioned between the limit switch actuators before proceeding with adjustments. 1. Remove control panel cover and locate the limit switch assembly. 2. Disengage the unit’s manual disconnect (see page 12), then manually open the gate to its full open position (note direction of limit nut travel). 3. Adjust the open limit nut by depressing the retaining bracket to allow nut to spin freely.
UL325 ENTRAPMENT PROTECTION Force Control PRIMARY ENTRAPMENT PROTECTION ADJUSTMENTS Force Control Set the force control pot such that the unit will complete a full cycle of gate travel but can be reversed off an obstruction without applying an unreasonable amount of force. On most operators this will be around the middle of the range.
UL325 ENTRAPMENT PROTECTION (CONTINUED) EDGE/PHOTO CLOSE EDGE/PHOTO OPEN This switch (S2-3) selects edge or photo sensor for the gate opening protection input. This switch (S2-4) selects edge or photo sensor for the gate closing protection input.
PROGRAM SETTINGS (DIP SWITCH S1) NOTE: For all S1, S2 and S4 switch settings to take effect, the Save Mode switch must be set to the off position. TIMER TO CLOSE ENABLE TIMER TO CLOSE This switch enables the auto close timer. The timer to close feature works in conjunction with the potentiometer located on the board.
CONTROL CONNECTION DIAGRAMS Accessory Terminal Block Accessory Terminal Block 10 11 11 12 12 13 13 14 14 15 16 17 17 18 20 15 16 18 19 19 20 11 22 33 44 55 66 77 88 99 10 24 Vac Accessory Power May Be Found On These Terminals R1 R2 R3 R4 24 Vac Soft Open Input (N.O.) 1 2 3 5 6 7 8 9 Close Overide Control Input (N.O.) Control Board 0 # OPEN CLOS Hard Open Override Control Input (N.O.) E ST OP OPEN CLOS E Stop/Reset Control Input (N.O.) ST OP OPEN Interrupt (Safety) Loop Input (N.O.
R1 R2 RADIO RCVR. All inputs are normally open and momentary, except the stop (N.C.). The following instructions are based upon UL325, and include recommendations for significant increase in safety. We strongly recommend that you follow the UL guidelines presented throughout the manual. Refer to instructions shipped with optional control devices for mounting, wiring, programming and adjustment.
PROGRAMMING THE REMOTE TO THE RECEIVER 1. Pry open the front panel of receiver case with a coin or a screwdriver. Re-connect power to operator (Figure 3). 2. Press and release the "learn" button on the receiver. The learn indicator light will glow steadily for 30 seconds. 3. Within 30 seconds, press and hold the button on the hand-held remote that you wish to operate your gate operator. The opener will now operate when the push button on either the receiver or the remote control is pressed.
ACCESSORY WIRING (CONTINUED) Hard Open Override Control Input Terminals 7 & 5 (Com) - Hard Open Override Control Input These terminals are intended for use only with the open control of a 3-button station that is installed within line of sight of the gate. A momentary activation of this input will cause the gate to open. Activation of this input for longer than three seconds will enable the control to be used as a constant pressure override device.
EARTH GROUND ROD INSTALLATION WARNING Proper grounding gives an electrical charge, such as from an electrical static discharge or a near lightning strike, a path from which to dissipate its energy safely into the earth. Without this path, the intense energy generated by lightning could be directed towards the gate operator. Although nothing can absorb the tremendous power of a direct lightning strike, proper grounding can protect the gate operator in most cases.
SEQUENCED ACCESS MANAGEMENT SYSTEM (SAMS) The Sequenced Access Management System or SAMS allows the customer more control when managing vehicular entrances to areas such as apartment complexes, businesses and gated communities. The basic concept of the system is that traffic is controlled by two gates installed in tandem, a fast moving gate such as a barrier gate operator and a slower moving more secure or ornamental gate such as a single or pair of slide/swing gate operator.
O P E R AT I O N A N D M A I N T E N A N C E ING WARNING IMPORTANT SAFETY INSTRUCTIONS ON WARNING To reduce the risk of SEVERE INJURY or DEATH: SEMENT 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. NEVER let children operate or play with gate controls. Keep the remote control away from children. 3. ALWAYS keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. Test the gate operator monthly.
SOLENOID ACTUATED BRAKE WARNING The brake is adjusted at the factory and should not need additional adjustments for the the life of the friction pad. Replace friction pads when necessary. Refer to the illustration for identification of components for the solenoid type brake system. To reduce the risk of SEVERE INJURY or DEATH: • Disconnect power BEFORE performing ANY adjustments. CAUTION FRICTION CLUTCH 1. Remove cotterpin from nut on the clutch shaft. 2.
CONTROL BOARD PROGRAMMING AND FEATURES (CONTINUED) FORCE CONTROL Set the force control pot such that the unit will complete a full cycle of gate travel but can be reversed off an obstruction without applying an unreasonable amount of force. On most operators this will be around the middle of the range. NOTE: For LED location refer to illustration on previous page.
TROUBLESHOOTING FAULT OPERATOR FAILS TO RUN POSSIBLE CAUSE 1) Improper wired stop control 2) Fault in the operator check the yellow diagnostic LED at the top right of the control board next to the programming dip switches.
TROUBLESHOOTING FAULT OPERATOR RUNS IN WRONG DIRECTION POSSIBLE CAUSE 1) Operator’s main power is out of phase (three phases only) 2) Operation directional switch OPERATOR RUNS BUT THEN STOPS AND REVERSES DIRECTION 1) Entrapment (force pot) incorrectly set 2) Gate is binding or not running smoothly 3) Clutch is not adjusted properly 4) Brake is not functioning properly 5) Observe red LEDs D29 and D31 6) RPM (Hall Effect) Sensor is not aligned MOTOR RUNS BUT GATE DOES NOT MOVE; OPERATOR STOPS AND ALARMS
SELF-REGULATING HEATER ACCESSORY Operators with installed heater kits are thermostatically controlled heaters that are utilized in areas where the temperature has the potential to drop below freezing. The heater is adjusted to 15˚C. To change the setting, rotate the temperature control knob on the heater to a new temperature setting. NOTE: The temperature readout is in degrees Celsius.
S I N G L E P H A S E S C H E M AT I C WARNING (BK) (B) 4 B 3 4 A 3 (W) (W) 5 A 6 1 B 2 4 (PU) (SL595 RD) (W) A 1 6 B 5 (BL/BK) (BK) 3 (BL/BK) (PU) (SL595 RD) 8 5 (BL) (YE) (SL595 WH) 3 2 1 (GY) (SL595 GN) 115V BRAKE SOLENOID (BK) 208V/230V MOTOR CONNECTION 4 MOTOR OVERLOAD (SEE NOTE 3) BLACK (SL595 ORANGE) (B) (GY) SL595 GN) (BK) (BK) PRIMARY 2 1 (SEE NOTE 3) 2 8 5 (BL) (YE) (SL595 WH) (SEE NOTE 2) (W) L2 (BK) 208/230V ONLY (S) (S) O/L (BK) (W) 115V
SINGLE PHASE WIRING DIAGRAM WARNING To protect against fire and electrocution: • DISCONNECT power BEFORE installing or servicing operator. • Replace ONLY with fuse of same type and rating. Fuse: 3AG, 3.2A, 120V, SLO-BLO SEE NOTE 5 BLACK (SL595 ORANGE) MOTOR SEE NOTE 3 OVERLOAD LINE TO MOTOR 3 BL Y 8 5 OL PU 4 2 BK 115V.
T H R E E P H A S E S C H E M AT I C ON/OFF SWITCH (BK) L2 3 PHASE POWER IN 230V CONNECTION (SEE NOTE 3) OVERLOAD L1 (BK) (BK) (BK) 4 B 3 5 A 6 4 A 3 1 B 2 2 A 1 6 B 5 (GY) (SL595 GN) (BK) (PU) (SL595 RD) (BK) (YE) (SL595 WH) L3 (BK) (BK) (BK) GROUND SEE NOTE 3 BLACK (SL595 ORANGE) (GN) PRIMARY WARNING (SEE NOTE 2) 24VAC R1 R2 RADIO SIGNAL R3 R4 (100 db) (BK) (BK) 1 7 4 2 8 5 3 9 6 (YE) 2 (BK) CD 3 (YE) (SL595 WH) (YE) (YE) (RD) (RD) (YE) (YE) (BL)
THREE PHASE WIRING DIAGRAM WARNING To protect against fire and electrocution: • DISCONNECT power BEFORE installing or servicing operator. • Replace ONLY with fuse of same type and rating. Fuse: 3AG, 3.2A, 120V, SLO-BLO BLACK (SL595 ORANGE) CONTACTOR YELLOW LOAD 24VAC/60VA FUSE 3.
SAFETY ACCESSORIES FOR SECONDARY ENTRAPMENT PROTECTION The following devices are acceptable for Safety Accessories for secondary entrapment protection. PHOTO-ELECTRIC CONTROLS MODEL CPS-N4 AOMRON DESCRIPTION Emitter, receiver and mounting brackets - 30' (9 m) Maximum Range Photocell/Electric Eye - 30' (9 m) Maximum Range VOLTAGE +24V ac/dc +24V ac/dc SENSING EDGES MODEL G65MG0204 G65MG0205 G65ME12C5 G65MGR205 G65MGS205 DESCRIPTION Miller MG020 2-wire electric edge for gates. Sensitized on three sides.
REPAIR PARTS SERVICE KITS INDIVIDUAL PARTS ITEM PART # 1 22-120 22-240 22-575-1 2 80-9001 3 12-4164 4 15-50B24LGH 5 10-30678 6 23-34815 7 16-5L304 8 17-6014 9 K20-1050B-2P K20-3100M-5 DESCRIPTION Brake solenoid, 115V Brake solenoid, 230-460V Brake solenoid, 575V Feather key Flange bearing mount Drive sprocket, 50B24 x 1" Lock bar Stop/Reset button V belt cogged Motor pulley Motor - models SL575-50-11, SL575-50-21, SL575-50-81 Motor - models SL575-100-11, SL575-100-21, SL575-100-81 Motor - model SL575-50-
I L L U S T R AT E D PA R T S 5 9 8 K4 (K75-34842) 3 7 K6 (K75-19977) 10 4 K7 (K72-34844) K8 (K72-34845) K2 (K75-34824) K3 (K75-34828) K5 (K29-32410) 1 2 6 K1 (71-B120) (71-B240) (71-B575) K3 (K75-34828) 35
ELECTRICAL BOX 5 3 4 7 1 3 9 K1 (K72-34818) 2 6 8 INDIVIDUAL PARTS ITEM 1 2 3 4 5 6 7 PART # K001A5566 312HM 13-10024 23-10041 03-8024-K 23-34822 21-3260-1 8 21-10298-1 23-30716 9 25-2006 25-2008 25-2010 25-2015 25-4002-SK K74-18379 SERVICE KITS DESCRIPTION Control board Radio - 315 MHz Limit nut Limit switch Contactor Open/close switch Transformer 115/208/230/460Vac/60VA Transformer - 575Vac/100VA Stop switch VARIABLE PARTS Overload - 6 AMP - SL575-50-21, SL575-50-81 Overload - 8 AMP - SL575
NOTES 37
NOTES 38
NOTES 39
WARRANTY POLICY AND SERVICE LIFTMASTER® TWO YEAR LIMITED WARRANTY The Chamberlain Group, Inc. warrants to the final purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of two years from the date of purchase. The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and testing.