RSW12V™ & RSW12VH™ VEHICULAR SWING GATE OPERATOR INSTALLATION MANUAL SOL AR LE CAPAB RI O ES. SEE ACCESS Your model may look different than the model illustrated in this manual. STOP IMPORTANT NOTE: The gate operation may be limited until the battery is fully charged. THIS PRODUCT IS TO BE INSTALLED AND SERVICED BY A TRAINED GATE SYSTEMS TECHNICIAN ONLY. Visit www.liftmaster.com to locate a professional installing dealer in your area.
TABLE OF CONTENTS SAFETY Safety Symbol and Signal Word Review UL325 Model Classifications Safety Installation Information Gate Construction Information Required Safety Protection Devices Important Safety Information 1-7 PROGRAMMING 1 2 3 4 5 6-7 INTRODUCTION 8 Operator Specifications Carton Inventory Hardware Inventory 8 8 8 INSTALLATION Site Preparation Types of Installations Standard Installation Compact Installation Only Standard and Compact Installation WIRING Earth Ground Rod Power Wiring Connec
SAFETY » UL325 MODEL CLASSIFICATIONS I CLASS I – RESIDENTIAL VEHICULAR GATE OPERATOR A vehicular gate operator (or system) intended for use in a home of one-to four single family dwellings, or a garage or parking area associated therewith.
SAFETY » SAFETY INSTALLATION INFORMATION 1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component. Each gate system is specifically designed for an individual application. 8. Controls intended for user activation must be located at least 6 feet (1.8 m) away from any moving part of the gate and where the user is prevented from reaching over, under, around or through the gate to operate the controls.
SAFETY » GATE CONSTRUCTION INFORMATION Vehicular gates should be installed in accordance with ASTM F2200: Standard Specification for Automated Vehicular Gate Construction. For a copy, contact ASTM directly at 610-832-9585 or www.astm.org. 1. GENERAL REQUIREMENTS 1.1 Gates shall be constructed in accordance with the provisions given for the appropriate gate type listed, refer to ASTM F2200 for additional gate types. 1.
SAFETY » REQUIRED SAFETY PROTECTION DEVICES To prevent SERIOUS INJURY or DEATH from a moving gate: • Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate. • Locate entrapment protection devices to protect in BOTH the open and close gate cycles. • Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts or walls.
SAFETY » IMPORTANT SAFETY INFORMATION INSTALLATION To prevent SERIOUS INJURY or DEATH from a moving gate: • Pinch points must be guarded at all times. Install enclosed-style gate tracks and roller guards. • Place screen mesh 4 feet (1.2 m) high on the gate to prevent access through openings anywhere the gate may travel. • Mount controls at least 6 feet (1.8 m) from the gate or ANY moving part of the gate. • Install Warning signs on EACH side of gate in PLAIN VIEW.
SAFETY » IMPORTANT SAFETY INFORMATION ADDITIONAL FEATURES To prevent SERIOUS INJURY or DEATH from a moving gate: • Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate. • Locate entrapment protection devices to protect in BOTH the open and close gate cycles. • Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts or walls.
INTRODUCTION » OPERATOR SPECIFICATIONS + CARTON INVENTORY + HARDWARE INVENTORY OPERATOR SPECIFICATIONS This model is intended for use in vehicular swing gate applications: Gate Classifications: CLASS I & II Main Supply (Motor): 12 Vdc Accessory Power: 12 V nominal Class II battery voltage source is limited to: • Solar or AC Cable up to 50 feet - 500 mA 27.
INSTALLATION » SITE PREPARATION + TYPES OF INSTALLATIONS SITE PREPARATION BEFORE installing the operator, be sure to check the following: • Gate is constructed and installed according to ASTM F2200 standards • Gate fits specifications of operator • National and local building codes • Earth ground rod • UL approved conduit for low and high voltage • Mounting considerations post or pad • Operator placement SAFETY CONSIDERATIONS: • Warning signs • Entrapment devices such as loops, contact sensors and non-cont
INSTALLATION » STANDARD INSTALLATION CONCRETE PAD AND OPERATOR ATTACHMENT MOUNTING FOOTPRINT 14" 13.6" 12.2" 4 Concrete Anchors 1/2" x 3 1/2" 17" NOTE: An alternative to a concrete pad is to post mount the operator (refer to accessories). 6" Above Ground 30" Below Ground Concrete Pad 28" 24" SAMPLE STANDARD INSTALLATION Hinge Center OUT 26" Post 2" IN 25" 14" 35.5" Long Arm 10" 29.
INSTALLATION » STANDARD INSTALLATION POSITION THE GATE BRACKET SAMPLE STANDARD INSTALLATION IS SHOWN ON PREVIOUS PAGE. Gate Hinge Center A OUT OUT IN IN E B 10" C Wall Short Arm D MINUS 10" D Long Arm DISTANCE Concrete Pad Dimension (A) thru (E) are from the center of one pivot point to the center of another pivot point. Caution: If the gate is longer than 18 feet, follow CHART A: A-2. If this dimension is between 20 and 32 inches, a compact installation is necessary.
INSTALLATION » COMPACT INSTALLATION ONLY DETERMINE LOCATION FOR CONCRETE PAD AND OPERATOR TOP VIEW OF OPERATOR AND GATE DO NOT run the operator until instructed. Refer to the illustration to determine the measurements and location of the concrete pad. NOTE: When lifting the operator use the handle to avoid damaging the operator.
INSTALLATION » COMPACT INSTALLATION ONLY SHORTEN THE OPERATOR ARM For a compact installation the operator arm will have to be shortened. Take the operator arm apart and remove the inner sleeves from the outer tubing. 1 1 2 Cut the outer tubing of the operator arm to the lengths shown. the arm back together and adjust the arm to the measurements 3 Putas shown.
INSTALLATION » STANDARD INSTALLATION + COMPACT INSTALLATION WELD THE OPERATOR ARM Once the operator arm measurements are verified: Weld the gate bracket to the gate. 1 2 Weld the short arm section. 3 Weld the long arm section. 1 3 NOTE: Completely weld around the outer tubing and bracket. 2 SECURE THE OPERATOR ARM TO THE OUTPUT SHAFT 1 Position the operator arm onto the output shaft so that the pin slides into the slot.
WIRING » POWER WIRING POWER WIRING This operator can be powered by the internal receptacle, an external receptacle or a solar panel (not provided). INTERNAL RECEPTACLE 120 VAC POWER WIRE (STRANDED COPPER WIRE) Wire Gauge 16 - 100 feet (30 m) Wire Gauge 10 - 1000 feet (305 m) CHGR OVLD NOTE: All power wiring should be on a dedicated circuit, calculated using NEC guidelines. National and local codes and conditions must be reviewed for suitability of wire installation. Remove the access panel.
WIRING » POWER WIRING + CONNECT BATTERIES POWER WIRING SOLAR PANEL (NOT PROVIDED. SEE ACCESSORIES.) The solar panel(s) must be located in an open area clear of obstructions and shading for the entire day. The gate operator is not supported in northern climates where temperatures reach below -4˚F. This is due to cold weather and a reduced number of hours of sunlight during the winter months. Cycle rate may vary from solar chart for areas that reach below 32˚F.
WIRING » PRIMARY / SECONDARY OPERATORS PRIMARY/SECONDARY OPERATORS NOTE: Use the Dual Gate Wiring Kit. Refer to the accessory page for more information. Before digging, contact local underground utility locating companies. Choose one operator to be the primary and the other operator to be the secondary. NOTES: • The gate with the longer travel span must be set as the primary operator (GATE 1).
ADJUSTMENT » LEARN LIMITS To reduce the risk of SEVERE INJURY or DEATH: • Without a properly installed safety reversal system, persons (particularly small children) could be SERIOUSLY INJURED or KILLED by a moving gate. • Too much force on gate will interfere with proper operation of safety reversal system. • NEVER increase force beyond minimum amount required to close gate. • NEVER use force adjustments to compensate for a binding or sticking gate.
ADJUSTMENT » LEARN LIMITS SINGLE GATE LEFT-HAND SIDE 1 the gate. Make sure the operator arm is properly seated on the output 1 Close shaft (the pin must fit into the slot). Make sure the handle is released on the operator arm and the learn limit cam is touching the learn limit switch. ey t id r s e In op r P PROGRAM OPEN Manually open the gate to the desired open position. 2 ey t id r s e In op r P 2 3 Tighten the handle on the operator arm. and release the LEARN LIMITS BUTTON.
ADJUSTMENT » LEARN LIMITS SINGLE GATE RIGHT-HAND SIDE 1 the gate. Make sure the operator arm is properly seated on the output 1 Close shaft (the pin must fit into the slot). Make sure the handle is released on the operator arm and the learn limit cam is touching the learn limit switch. PROGRAM OPEN Manually open the gate to the desired open position. e ty id r s e In op r P e ty id r s e In op r P 2 3 Tighten the handle on the operator arm. 2 and release the LEARN LIMITS BUTTON.
ADJUSTMENT » LEARN LIMITS DUAL GATE (LEFT-SIDE PRIMARY OPERATOR) the gates. Make sure the operator arm is properly seated on the output 1 1 Close shaft (the pin must fit into the slot) of both operators and the learn limit cam is touching the learn limit switch on both operators. Make sure the handle is released on the operator arm of the PRIMARY operator ONLY. PROGRAM OPEN Manually open the primary gate.
ADJUSTMENT » LEARN LIMITS DUAL GATE (RIGHT-SIDE PRIMARY OPERATOR) 1 the gates. Make sure the operator arm is properly seated on the output 1 Close shaft (the pin must fit into the slot) of both operators and the learn limit cam is touching the learn limit switch on both operators. Make sure the handle is released on the operator arm of the PRIMARY operator ONLY. PROGRAM OPEN Manually open the primary gate.
ADJUSTMENT » FORCE ADJUSTMENT + TEST FORCE ADJUSTMENT The operator is equipped with an obstruction sensing feature. If the gate encounters an obstruction the operator will automatically reverse direction for a short time and stop. Based on the length and weight of the gate it may be necessary to make force adjustments. The force adjustment should be high enough that the gate will not reverse by itself and not cause nuisance interruptions but low enough to prevent serious injury to a person.
PROGRAMMING » REMOTE CONTROLS + KEYLESS ENTRY + ERASE ALL CODES + ALTERNATE RADIO RECEIVER INSTALLATION A combined total of 50 remote controls and keyless entry PINs can be programmed to the operator. For highest level of security, we recommend the Security✚ line of products. Refer to Accessories. ® TO ADD OR REPROGRAM A REMOTE CONTROL (NOT PROVIDED) LEARN XMITTER 1 1 the remote control button. The LED will flash and the alarm output will 2 Press activate twice.
ADDITIONAL FEATURES » TIMER-TO-CLOSE + AUTO OPEN JUMPER + HEATER + PARTY MODE TIMER-TO-CLOSE (TTC) The TIMER-TO-CLOSE feature can be set to automatically close the gate after a specified time period. The TTC is factory set to OFF. If the TTC is set to the OFF position, then the gate will remain open until the operator receives another command from a remote control or the SINGLE BUTTON control. TIMER TO CLOSE 1 TO SET THE TIMER-TO-CLOSE Rotate the TIMER-TO-CLOSE dial to the desired setting.
ADDITIONAL FEATURES » ENTRAPMENT PROTECTION DEVICES To prevent SERIOUS INJURY or DEATH from a moving gate: • Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate. • Locate entrapment protection devices to protect in BOTH the open and close gate cycles. • Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts or walls.
OPERATION AND MAINTENANCE » MANUAL DISCONNECT + RESET BUTTON + REMOTE CONTROL + SLEEP MODE MANUAL DISCONNECT Release the handle on the operator arm to allow the gate to be opened and closed manually. On a dual gate application the handle must be released on both operators. To resume normal function tighten the handle by pushing it down. RESET BUTTON The reset button is located on the front of the operator and serves several functions.
OPERATION AND MAINTENANCE » MAINTENANCE + BATTERY MAINTENANCE Disconnect all power to the operator before servicing.
TROUBLESHOOTING » DIAGNOSTIC ERROR CODES CHART The operator is programmed with self-diagnostic capabilities. The diagnostic LED will flash a number of times then pause signifying it has found a potential issue. Consult Diagnostic Error Codes Chart below. CONTINUOUS FLASHES (HEARTBEAT) POWER ON 2 FLASHES STOP NOT CONNECTED Operator is in sleep mode - Normal Operation Stop is not connected. • Party Mode may be activated.
TROUBLESHOOTING » TROUBLESHOOTING CHART OPERATOR DOES NOT RUN. DIAGNOSTIC LED NOT ON. OPERATOR POWERS UP BUT DOES NOT OPERATE. RELAYS “CLICK” WHEN REMOTE CONTROL OR SINGLE BUTTON CONTROL (SBC) COMMAND IS GIVEN, BUT THE OPERATOR DOES NOT MOVE OR GATE DISCONNECTED. • Power not connected. Make sure the AC/Solar input is connected and that at least one battery is connected with the corresponding fuse intact. • Low or defective battery.
TROUBLESHOOTING » TROUBLESHOOTING CHART OPERATOR DOES NOT RESPOND TO COMMAND. GATE STOPS AND REVERSES IMMEDIATELY AFTER IT STARTS MOVING. GATE OPENS BUT DOES NOT CLOSE. GATE DOES NOT CLOSE AUTOMATICALLY WITH TIMER TO CLOSE ENABLED. • Battery not connected. At least one charged battery must be connected for the operator remote control to operate. Verify battery fuse is intact. Check battery connections and battery voltage to be above 11.5Vdc. Replace batteries if necessary.
ACCESSORIES ENTRAPMENT PROTECTION DEVICES THE PROTECTOR SYSTEM PHOTOELECTRIC SENSORS The photoelectric sensors are designed to detect an obstacle in the path of the electronic beam and stop the operator. Includes mounting brackets. Model 50-220 ® SENSING EDGE (2-WIRE, NON-MONITORED) Sensing edges can detect an obstacle upon contact and stop the operator. Models G65MG0204, G65MG0205, G65MGR205, and G65MGS205 SENSING EDGE CHANNEL Mounting channel for all MG020 type edges.
ACCESSORIES WIRELESS ACCESS CONTROL RECEIVER Access control receiver for up to 450 Security✚ remote controls. Model STAR450-315 ® HEATER Keeps operator, gearbox and batteries at suitable temperature when outside temperature is below 0°F for extended periods of time. Models HTRKITRSW (for Swing operator, includes bracket for optimal heater location) and G6518CSW (Swing replacement heater only) LOOP DETECTOR Low power loop detectors.
WARRANTY LIFTMASTER THREE YEAR LIMITED WARRANTY The Chamberlain Group, Inc. warrants to the first purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of THREE years from the date of purchase. The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and testing.