RAMSET Important Safety Requirements & Instructions....................................................................................1 Responsibilities of Installers and Technicians.....................................................................................2 Important Safety Requirements by UL Standards...............................................................................3 Classes of Vehicular Gate Operators................................................................................
RAMSET Responsibilities of installers and technicians installation: • Read and understand the instruction manual before attempting RAM 302 any installation. • Do not exceed the equipment specifications. • Insure a safe and proper installation. • Install this equipment in accordance with the Ul 325 specifications. • Make sure to eliminate any pinch points existing on the installation. (ie. Rollers, arms…etc.) Safety devices: • Remove or protect all pinch points from the gate operator’s arms.
RAMSET IMPORTANT SAFETY REQUIREMENTS BY UL STANDARDS a) Install the gate operator only when: 1. The operator is appropriate for the construction of the gate and the usage Class of the gate, 2. All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.22 m) above the ground to prevent a 2 1/4 inch (57.
RAMSET classes of vehicular gate operators RAM 302 Vehicular horizontal slide-gate operator (or system) - A vehicular gate operator (or system) that controls a gate which slides in a horizontal direction that is intended for use for vehicular entrance or exit to a drive, parking lot, or the like.
RAMSET RAM 302 General Specifications: RAM 302 maximum gate size & Weight: 18’ @ 600 lbs gate traveling speed: Approx 90° opening in 16 sec motor: 1/2 hp, 120 VAC, 4.5 amp, 1625 rpm cycles: Continuous operating temperature: -10° F to 160° F heavy duty worm gear: Lubricated in an oil bath for smooth and quiet operation.
RAMSET Installation specifications Concrete PAD CONSTRUCTION: Dimensions given for the pad are based on soil bearing shear of 2000 P.S.F. These figures may have to be adjusted depending on local soil conditions. RAM 302 1. Construct form for mounting pad according to dimensions shown in Figure 1 and 2. 2. Locate mounting pad according to dimensions given in illustration. 3. Level top edge of form. 4. Set reinforcing bars and wire mesh. 5. Allow pad to cure for 48 hours, and remove forms. 6.
RAMSET GATE TRAVEL ADJUSTMENT Figure 3 Figure 4 RAM 302 hookup electrical power Outlet Leads Note: 15 amp wires connected to independent Gate travel is adjusted by loosening the limit Cams and adjusting them until proper gate travel has been breaker. achieved. Standard Installation for Gates from 8’ to 14’ in Length Figure 5 www.ramsetinc.
RAMSET RAM 302 STANDARD INSTALLATION FOR GATES FROM 14’ TO 18’ IN LENGTH Figure 6 space required for a standard Gate in the open position Figure 7 8 www.ramsetinc.
RAMSET RAM 302 Compact installation for gates up to 14’ in length Figure 8 Minimum space required for compact installation 20” minimum space required between, open gate and wall for this compact installation. Figure 9 www.ramsetinc.
RAMSET SENSOR INSTALLATION RAM 302 Ramset Gate Operators should not be installed without non-contact sensing devices such as Loop Detectors, photo electric sensors or the equivalent. WARNING A non-contact sensor (photoelectric sensor or equivalent) and a contact sensor (edge device or equivalent) is required on each individual installation to comply with UL325. Reversing Loops on the ground floor, prevents gate from closing when vehicle is in loop area.
RAMSET PUSHBUTTON CONTROLS Three pushbuttons are located under the dip switches for operation of the gate (see Figure 11). The opening, stop and closing buttons can be utilized to set limit switches and verify proper system operation when installing or servicing an operator. L.E.D.’s light up when Opening, Closing or Stopped Stop Pressing this button will cause the gate to stop moving. Figure 11 RAM 302 Opening Pressing this button will cause the gate to open.
RAMSET DIP SWITCH CONFIGURATION Figure 13 RAM 302 “Intelligate” Control Board DIP SWITCH "A" Dip Switch "A" 1, 2 & 3; AUTOMATIC TIMER TO CLOSE GATE ‘0’ is “OFF” Switch 1 2 3 Gate Open Duration: 1 1 1 60 seconds 1 1 0 45 seconds 1 0 1 30 seconds 1 0 0 15 seconds Dip Switch "B" 3; “CONSTANT WARN” 0 1 1 10 seconds 0 1 0 05 seconds Used with JP2 “Relay Connections” : pins 7 & 8. Triggers a relay, for an alarm or light (not included), to be active anytime the gate is in motion.
RAMSET DIP SWITCH "C" Dip Switch "C" 1; “SECURE CLOSE” One second delay on the closing of the gate. Function: OFF Normal Operation ON When power is lost, then regained, control board checks status of the gate. If open and safety devices are cleared, gate will close automatically. Dip Switch "C" 6; “OPEN DELAY” One second delay on the opening of the gate. Dip Switch "C" 7; “LEFT / RIGHT” Sw.
RAMSET SAFETY Terminal strip Connection RAM 302 Figure 14 14 www.ramsetinc.
RAMSET Terminal # 1 - Common: Low voltage common. Terminal # 2 - Rev loop: Stops the gate from closing. If the gate is open, it holds the gate open. If the gate is closing, it stops and reopens the gate. If the gate is closed, the gate will remain closed. The function can be altered with Dip Switch “C” 4 (see “Dip Switch Configuration”). Used with loop detectors, photo eyes, safety edges…etc. Becomes active with a closed contact to common. Terminal # 3 - Close: Closes the gate.
RAMSET ramset “Intelligate” Control Board RAM 302 Introduction: Ramset’s “Intelligate” Control Board works with Sliding, Swinging and Overhead vehicular gate operators. It is controlled by a programmable microprocessor that reads and precisely executes all functions of the Control Board. The Control Board is powered by a separate mounted 24 VAC transformer. This allows no necessary board modifications between 110 VAC and 220 VAC single-phase applications.
RAMSET Wire board connections JP9 - Input Power: JP3 - 3 Button: 1) Open 2) Stop 3) Close 4) Common Used with a 3-button station to open, stop, and close the gate. The open and close are normally open connections and the stop is a normally closed connection, remove jumper wire when connecting 3 button station. Common and stop are also used with a photo eye used to protect the backplane of the operators. JP11 - Foot Pedal Plug: JP2 - Relay Connections: 1) 24 VDC. 2) 24 VAC 3) 5 VDC 4) Fully Open-N.O.
RAMSET RAM 302 parts Diagram Figure 16 36 RAM 302 38 37 17 34 33 25 7 35 8 23 28 32 13 31 10 29 30 26 20 11 24 21 14 6 9 12 3 5 18 2 4 22 27 16 15 1 18 www.ramsetinc.
RAMSET bill of materials for: Ram 302 part # PART DESCRIPTION 1 800-00-30 Chassis Base 1 2 800-02-09 Gear Reducer—Size 70, Ratio 900:1 1 3 800-04-10 Motor, Standard—120VAC 1/2 HP 1 4 800-08-25 Pulley, Steel—1/2” x 2 1/2” (AK25) 1 5 800-08-40 Pulley, Steel— 5/8” x 2 1/2” (AK25) 1 6 800-10-05 Belt—4L-170 1 7 800-14-06 Cover, Polyethylene 1 8 800-14-15 Cover, Polyethylene Cap Arm 1 9 800-14-21 Cover, Metal Control Board 1 10 800-20-05 Limit Switch - Swing Operator 2 1
RAMSET TROUBLESHOOTING Table RAM 302 CONDITION SOLUTION POSSIBLE CAUSES NO LIGHTS ARE 'ON'. 1. Circuit breaker popped. 2. 1/2 amp. fuse blown. 3. Power supply damaged on Control Board. 1. Reset circuit breaker. 2. Replace 1/2 amp. fuse. 3. Return Control Board for repair. GATE MOVES A COUPLE OF FEET AND THEN REVERSES. 1. E.R.D. too sensitive. 1. A) for 1/2 hp motors: turn dip switch "A" 4 'On'. "EXIT" L.E.D. IS ALWAYS 'ON'. 1. Faulty accessory connected to the "Exit". 1.
RAMSET RAM 302 Gate entrance Safety Precautions WARNING: 1. Never let children operate or play with gate controls. Keep the controls away from children. 2. The entrance is for vehicles only. Pedestrians should use a separate entrance. 3. Always keep people, children and objects away from the gate while the gate is in operation. No one should cross the area of a moving gate. 4.
RAM 302 Opening the way… Important information for the homeowner Ask your technician about all the features of our new Ramset operator. Safety devices, such as reverse loops, phantom loops, photo eyes, or miller edges must be installed on your gate before the operator may be used. Ask your technician which safety devices best suit your safety needs. Read your warranty certificate and fill out your warranty extension card.
RAM 302 Ramset Optional Accessories Fire Box LCD-KP liquid Crystal Display-Keypad 1,024 Codes 5,112 Event Log LCD Display 7-Day Timer Time Zones Latching Stainless Steel Faceplate Allows the fire department to open the gate in the case of an emergency. Post Mounts 1/4” angle iron flats. 3/16” square tubing legs. Used to mount the operator off the ground. Magnetic Lock 12/24V DC. 1100 lb holding force. Secures the gate(s) closed.