R_Ramset_Ram3000.
R_Ramset_Ram3000.qxd 8/19/05 4:56 PM Page 2 www.ramsetinc.
R_Ramset_Ram3000.qxd 8/19/05 4:56 PM Page 3 TABLE OF CONTENTS Important Safety Requirements & Instructions …………………………………………….........……. 1 Responsibilities of Installers and Technicians …………………………………………………………. 2 Important Safety Requirements by UL Standards…………………………………….……………….. 3 Classes of Vehicular Gate Operators ...………………………………………………………………... 4 General Specifications ………………………………………………………………………………….... 5 Installation Specifications ………………………………………………………………………………...
R_Ramset_Ram3000.qxd 8/19/05 4:56 PM Page 4 RAM 3000 UL - 3100 UL - 3200 UL RAMSET RESPONSIBILITIES OF INSTALLERS AND TECHNICIANS INSTALLATION: • READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE ATTEMPTING ANY INSTALLATION. • DO NOT EXCEED THE EQUIPMENT SPECIFICATIONS. • INSURE A SAFE AND PROPER INSTALLATION. • INSTALL THIS EQUIPMENT IN ACCORDANCE WITH THE UL 325 SPECIFICATIONS. • MAKE SURE TO ELIMINATE ANY PINCH POINTS EXISTING ON THE INSTALLATION. (ie. ROLLERS, ARMS…etc.
R_Ramset_Ram3000.qxd 8/19/05 4:56 PM Page 5 IMPORTANT SAFETY REQUIREMENTS BY UL STANDARDS Prior to installation, the following must be observed: (per UL 325.51.8.4). f) All warning signs and placards must be installed a) Install the vehicular gate operator only when: g) For Vehicular Gate Operators utilizing a non- 1) The Vehicular Gate Operator is appropriate for the construction of the gate and the usage class of the gate. contact sensor in accordance with 30A.1.
R_Ramset_Ram3000.qxd 8/19/05 4:57 PM Page 6 RAM 3000 UL - 3100 UL - 3200 UL RAMSET CLASSES OF VEHICULAR GATE OPERATORS Vehicular horizontal slide-gate operator (or system) - A vehicular gate operator (or system) that controls a gate which slides in a horizontal direction that is intended for use for vehicular entrance or exit to a drive, parking lot, or the like.
R_Ramset_Ram3000.qxd 8/19/05 4:57 PM Page 7 RAM 3000 UL - 3100 UL - 3200 UL RAMSET RAM 3000 UL - RAM 3100 UL - RAM 3200 UL GENERAL SPECIFICATIONS: MODEL: RAM 3000 UL RAM 3100 UL RAM 3200 UL Max. Gate Length: 22 feet 22 feet 22 feet Max. Gate Weight: 800 lbs. 1200 lbs. 1200 lbs.
R_Ramset_Ram3000.qxd 8/19/05 4:57 PM Page 8 RAM 3000 UL - 3100 UL - 3200 UL RAMSET INSTALLATION SPECIFICATIONS CONCRETE PAD CONSTRUCTION: Dimensions given for the pad are based on soil bearing shear of 2000 P.S.F. These figures may have to be adjusted depending on local soil conditions. 1. Construct form for mounting pad according to dimensions shown in Figure 1 and 2. 2. Locate mounting pad according to dimensions given in illustration. 3. Level top edge of form. 4.
R_Ramset_Ram3000.qxd 8/19/05 4:57 PM Page 9 HOOKUP ELECTRICAL POWER RAM 3000 UL - 3100 UL - 3200 UL RAMSET GATE TRAVEL ADJUSTMENT Figure 3 Figure 4 Outlet Leads Note: 15 amp wires connected to independent breaker. Gate travel is adjusted by loosening the limit Cams and adjusting them until proper gate travel has been achieved. STANDARD INSTALLATION FOR GATES FROM 8' TO 16' IN LENGTH Figure 5 www.ramsetinc.
R_Ramset_Ram3000.qxd 8/19/05 4:57 PM Page 10 RAM 3000 UL - 3100 UL - 3200 UL RAMSET STANDARD INSTALLATION FOR GATES FROM 16' TO 22' IN LENGTH Figure 6 SPACE REQUIRED FOR A STANDARD GATE IN THE OPEN POSITION Figure 7 8 www.ramsetinc.
R_Ramset_Ram3000.qxd 8/19/05 4:57 PM Page 11 RAM 3000 UL - 3100 UL - 3200 UL RAMSET COMPACT INSTALLATION FOR GATES UP TO 14' IN LENGTH Figure 8 MINIMUM SPACE REQUIRED FOR COMPACT INSTALLATION 20" minimum space required between, open gate and wall for this compact installation. Figure 9 www.ramsetinc.
R_Ramset_Ram3000.qxd 8/19/05 4:57 PM Page 12 RAM 3000 UL - 3100 UL - 3200 UL RAMSET SENSOR INSTALLATION Ramset Gate Operators should not be installed without non-contact sensing devices such as Loop Detectors, photo electric sensors or the equivalent. A non-contact sensor (photoelectric sensor or equivalent) and a contact sensor (edge WARNING: device or equivalent) is required on each individual installation to comply with UL325.
R_Ramset_Ram3000.qxd 8/19/05 4:57 PM Page 13 PUSHBUTTON CONTROLS Three pushbuttons are located under the dip switches for operation of the gate (see Figure 11). The opening, stop and closing buttons can be utilized to set limit switches and verify proper system operation when installing or servicing an operator. Opening Pressing this button will cause the gate to open. L.E.D.’s light up when Opening, Closing or Stopped Stop Pressing this button will cause the gate to stop moving.
R_Ramset_Ram3000.qxd 8/19/05 4:57 PM Page 14 RAMSET RAM 3000 UL - 3100 UL - 3200 UL DIP SWITCH CONFIGURATION Figure 13 "Intelligate" Control Board DIP SWITCH "A" Dip Switch "A" 1, 2 & 3; AUTOMATIC TIMER TO CLOSE GATE ‘0’ is “OFF” Switch (Constant warning when gate is in motion). ‘1’ is “ON” 1 2 3 Gate Open Duration: Sw. 1 1 1 60 seconds OFF No effect.
R_Ramset_Ram3000.qxd 8/19/05 4:57 PM Page 15 DIP SWITCH "C" Dip Switch "C" 7; “LEFT / RIGHT” Dip Switch "C" 1; “SECURE CLOSE” Sw. Function: OFF Normal Operation ON When power is lost, then regained, control board checks status of the gate. If open and safety devices are cleared, gate will close automatically. Sw. Function: OFF Left hand installations - All operators come factory set for left hand operation. ON Right hand installations - Reverses motor & limit switches without moving any wires.
R_Ramset_Ram3000.qxd 8/19/05 4:57 PM Page 16 RAM 3000 UL - 3100 UL - 3200 UL RAMSET TERMINAL STRIP CONNECTION Figure 14 14 www.ramsetinc.
R_Ramset_Ram3000.qxd 8/19/05 4:57 PM Page 17 accept any commands. After the 6 minutes the 24 VDC is removed from the alarm connection and the board resets to normal operation. TERMINAL STRIP CONNECTIONS Terminal # 1 - COMMON: Low voltage common. Terminal # 9 and 10 - LIMIT 1 & LIMIT 2: Terminal # 2 - REV LOOP: Stops the gate from closing. If the gate is open, it holds the gate open. If the gate is closing, it stops and reopens the gate. If the gate is closed, the gate will remain closed.
R_Ramset_Ram3000.qxd 8/19/05 4:57 PM Page 18 RAM 3000 UL - 3100 UL - 3200 UL RAMSET RAMSET “INTELLIGATE” CONTROL BOARD Introduction: sary board modifications between 110 VAC and Ramset’s “Intelligate” Control Board works 220 VAC single-phase applications. with Sliding, Swinging and Overhead vehicular functions of the Control Board are: 0 - 60 seconds gate operators. It is controlled by a program- automatic close timer, self adjusting E.R.D.
R_Ramset_Ram3000.qxd 8/19/05 4:57 PM Page 19 WIRE BOARD CONNECTIONS JP9 - Input Power: 1,2) 24 VAC power. Connection from external transformer to power Control Board. JP3 - 3 Button: 1) Close 2) Stop 3) Open 4) Common Used with a 3-button station to open, stop, and close the gate. The open and close are normally open connections and the stop is a normally closed connection, remove jumper wire when connecting 3 button station.
R_Ramset_Ram3000.qxd 8/19/05 4:58 PM Page 20 RAM 3000 UL - 3100 UL - 3200 UL RAMSET RAM 3000 UL - RAM 3100 UL - RAM 3200 UL PARTS DIAGRAM 66 Figure 16 24 37 64 71 24 42 34 35 37 63 39 27 63 36 47 40 30 37 4 41 45 65 50 58 63 53 2 61 59 49 33 27 60 25 29 33 54 57 31 38 26 26 5 62 27 13 57 6 72 7 9 8 22 25 43 23 33 56 67 3 70 57 18 48 44 19 57 20 13 27 38 30 52 21 12 55 51 24 11 28 24 10 15 14 17 68 27 69 15 1 18 32 38 46 28 70 www.
R_Ramset_Ram3000.
R_Ramset_Ram3000.
R_Ramset_Ram3000.qxd 8/19/05 4:58 PM Page 23 TROUBLESHOOTING TABLE CONDITION SOLUTION POSSIBLE CAUSES NO LIGHTS ARE 'ON'. 1. Circuit breaker popped. 2. 1/2 amp. fuse blown. 3. Power supply damaged on Control Board. 1. Reset circuit breaker. 2. Replace 1/2 amp. fuse. 3. Return Control Board for repair. GATE MOVES A COUPLE OF FEET AND THEN REVERSES. 1. E.R.D. too sensitive. 1. A) for 1/2 hp motors: turn dip switch "A" 4 'On'. "EXIT" L.E.D. IS ALWAYS 'ON'. 1.
R_Ramset_Ram3000.qxd 8/19/05 4:58 PM Page 24 RAM 3000 UL - 3100 UL - 3200 UL RAMSET GATE ENTRANCE SAFETY PRECAUTIONS WARNING: 1. Never let children operate or play with gate controls. Keep the controls away from children. 2. The entrance is for vehicles only. Pedestrians should use a separate entrance. 3. Always keep people, children and objects away from the gate while the gate is in operation. No one should cross the area of a moving gate. 4.
8/19/05 4:58 PM Page 25 Opening the way… Important information for the homeowner Ask your technician about all the features of our new Ramset operator. Safety devices, such as reverse loops, phantom loops, photo eyes, or miller edges must be installed on your gate before the operator may be used. Ask your technician which safety devices best suit your safety needs. Read your warranty certificate and fill out your warranty extension card.
R_Ramset_Ram3000.qxd 8/19/05 4:58 PM Page 26 RAM 3000 UL - 3100 UL - 3200 UL RAMSET RAMSET OPTIONAL ACCESSORIES 20-05 Mounting Post for Access Control 50-40 Ramset Remote Control Transmitter Fire Box Key Switch Box Emergency Entry Box Ramset Magnetic Lock BBS Battery Back-up System (Heavy Duty Industrial) Ramset Radio Receiver RKLE Keyless Entry System ILD-24 Ramset Plug-in Loop Detectors Ramset RPI Maintain all operations of the gate during power outages.
R_Ramset_Ram3000.qxd 8/19/05 4:58 PM Page 27 www.ramsetinc.
R_Ramset_Ram3000.