FOR CLASS II, III, IV VEHICULAR GATE OPERATORS
www.ramsetinc.
TABLE OF CONTENTS Important Safety Requirements & Instructions …………………………………………….........…….………… 1 Responsibilities of Installers and Technicians ………………………………………………………….………… 2 Important Safety Requirements by UL Standards …………………………………….………………………… 3 Classes of Vehicular Gate Operators - Recommended Electrical Connection ……...……………..………… 4 General Specifications (RAM 2000 UL, RAM 2100 UL and RAM 2200 UL) ……………………....………………. 5 Installation Specifications / Sample Gate Hardware ………………………………………………..
RAM 2000 UL - 2100 UL - 2200 UL RAMSET RESPONSIBILITIES OF INSTALLERS AND TECHNICIANS INSTALLATION: • READ AND UNDERSTAND THE INSTRUCTION MANUAL BEFORE ATTEMPTING ANY INSTALLATION. • DO NOT EXCEED THE EQUIPMENT SPECIFICATIONS. • INSURE A SAFE AND PROPER INSTALLATION. • INSTALL THIS EQUIPMENT IN ACCORDANCE WITH THE UL 325 SPECIFICATIONS. • MAKE SURE TO ELIMINATE ANY PINCH POINTS EXISTING ON THE INSTALLATION. (ie. ROLLERS, ARMS…etc.
IMPORTANT SAFETY REQUIREMENTS BY UL STANDARDS Prior to installation of a Ramset gate operator, the following must be observed: (per UL 325.51.8.4). a) Install the vehicular gate operator only when: 1) The Vehicular Gate Operator is appropriate for the construction of the gate and the usage class of the gate. 2) All openings of a horizontal slide gate are guarded or screened from the bottom of the gate to a minimum of 4 feet (1.2 m.) above the ground to prevent a 2 1/4 inch (57.15 mm.
RAM 2000 UL - 2100 UL - 2200 UL RAMSET CLASSES OF VEHICULAR GATE OPERATORS Vehicular horizontal slide-gate operator (or system) - A vehicular gate operator (or system) that controls a gate which slides in a horizontal direction that is intended for use for vehicular entrance or exit to a drive, parking lot, or the like.
RAM 2000 UL - 2100 UL - 2200 UL RAMSET RAM 2000 UL - RAM 2100 UL - RAM 2200 UL GENERAL SPECIFICATIONS: RAM 2000 UL RAM 2100 UL RAM 2200 UL Max. Gate Length: 20 feet 20 feet 20 feet Max. Gate Weight: 450 lbs. 550 lbs. 550 lbs. Continuous Continuous Continuous Aerovox 65µƒ, 240V, 50/60Hz. protected S 1000AFC Aerovox 65µƒ, 240V, 50/60Hz. protected S 1000AFC Aerovox 65µƒ, 240V, 50/60Hz.
RAM 2000 UL - 2100 UL - 2200 UL RAMSET INSTALLATION SPECIFICATIONS 1. CLEARANCES: Gate must be level and balanced prior to installing gate springs, hardware, and Overhead Operator. Jambs must be installed on left and right sides of opening. Jambs must be plumbed and securely attached to both sides of wall. Between jamb and gate: 3/4" minimum. Bottom of gate to driveway floor: 2" minimum. Maximum Gate Dimensions: 20' Wide, 78" Minimum Tall. Consult building and safety standards.
RAM 2000 UL - 2100 UL - 2200 UL RAMSET 2. SAMPLE GATE HARDWARE: Note: Dimensions of Installation of gate hardware, must be verified with the gate hardware manufacturer. Figure 3 3. HEAD BRACKET: Figure 4 Install Head Bracket on the center position of overall gate opening as shown. Figure 4 Overhead Track must be centered above gate and leveled from front to back. If Head Bracket is to be installed onto concrete, use anchor bolts, if metal, then weld. 4" clearance between top of gate and opening www.
RAM 2000 UL - 2100 UL - 2200 UL RAMSET SPECIAL REQUIREMENT 143" 10" 22" 121" Figure 5 If track is required to be shortened, cut in the back part of rail, as shown Figure 5. SAFETY EDGE SENSOR PLACEMENT Safety edge sensor. Figure 6 Note: Appropriate tension torque is required in the springs for optimal gate function. 8 www.ramsetinc.
RAM 2000 UL - 2100 UL - 2200 UL RAMSET PHOTO EYE SENSOR PLACEMENT TO LIN E UP Photo Eye WITH EACH OTHE R Reflector 6" Clearance from spring 6" Figure 7 SAFETY LOOP SYSTEM INSTALLATION Ramset Gate Operators should not be installed without non-contact sensing devices such as Loop Detectors, Photo Electric Sensors or the equivalent.
RAM 2000 UL - 2100 UL - 2200 UL RAMSET SAFETY LOOP SYSTEM INSTALLATION Figure 8 Install a sensor Photo-eye aligned with Reflector from 18" to 24" from the floor. See figure 14 "Terminal Strip Connection" for hook up. Figure 9 10 www.ramsetinc.
PUSHBUTTON CONTROLS Three pushbuttons are located under the dip switches for operation of the gate (see Figure 9). The opening, stop and closing buttons can be utilized to set limit switches and verify proper system operation when installing or servicing an operator. Opening Pressing this button will cause the gate to open. L.E.D.’s light up when Opening, Closing or Stopped Stop Pressing this button will cause the gate to stop moving.
RAM 2000 UL - 2100 UL - 2200 UL RAMSET DIP SWITCH CONFIGURATION Figure 13 Dip Switch Up for "ON" Dip Switch Down for "OFF" DIP SWITCH "A" Dip Switch "A" 1, 2 & 3; AUTOMATIC TIMER TO CLOSE GATE ‘0’ is “OFF” Switch (Constant warning when gate is in motion). ‘1’ is “ON” 1 2 3 Gate Open Duration: Sw. 1 1 1 60 seconds OFF No effect.
DIP SWITCH "C" Dip Switch "C" 7; “LEFT / RIGHT” Dip Switch "C" 1; “SECURE CLOSE” Sw. Sw. Function: OFF Normal Operation ON When power is lost, then regained, control board checks status of the gate. If open and safety devices are cleared, gate will close automatically. Function: OFF Left hand installations - All operators come factory set for left hand operation. ON Right hand installations - Reverses motor & limit switches without moving any wires.
RAM 2000 UL - 2100 UL - 2200 UL RAMSET TERMINAL STRIP CONNECTION FOR OPTIONAL ACCESSORIES Figure 14 14 www.ramsetinc.
Terminal # 1 - COMMON: Low voltage common. sound for 6 minutes and the control board will not accept any commands. After the 6 minutes the 24 VDC is removed from the alarm connection and the board resets to normal operation. Terminal # 2 - REV LOOP: Used with safety edge mounted on post or back of gate. TERMINAL STRIP CONNECTIONS Stops the gate from closing. If the gate is open, it holds the gate open. If the gate is closing, it stops and reopens the gate.
RAM 2000 UL - 2100 UL - 2200 UL RAMSET RAMSET “INTELLIGATE” CONTROL BOARD Introduction: sary board modifications between 110 VAC and Ramset’s “Intelligate” Control Board works 220 VAC single-phase applications. with Sliding, Swinging and Overhead vehicular functions of the Control Board are: 0 - 60 seconds gate operators. It is controlled by a program- automatic close timer, self adjusting E.R.D.
WIRE BOARD CONNECTIONS JP9 - Input Power: 1,2) 24 VAC power. Connection from external transformer to power Control Board. JP3 - 3 Button: 1) Close 2) Stop 3) Open 4) Common Used with a 3-button station to open, stop, and close the gate. The open and close are normally open connections and the stop is a normally closed connection, remove jumper wire when connecting 3 button station. Common and stop are also used with a photo eye used to protect the backplane of the operators.
RAM 2000 UL - 2100 UL - 2200 UL RAMSET RAM 2000 UL - RAM 2100 UL - RAM 2200 UL EXPLODED VIEW 26 27 31 54 24 51 12 27 25 27 10 50 35 32 21 27 24 33 27 36 21 24 30 34 1 37 9 20 27 25 55 10 39 52 47 53 16 41 45 40 42 43 30 6 7 23 22 19 40 8 18 5 24 47 23 17 3 25 14 30 28 40 27 11 47 49 46 15 48 2 44 23 13 22 24 20 29 4 38 Figure 16 18 www.ramsetinc.
RAM 2000 UL - 2100 UL - 2200 UL RAMSET BILL OF MATERIAL FOR: RAM 2000 UL - RAM 2100 UL - RAM 2200 UL ITEM PART # PART DESCRIPTION RAM 2000 UL RAM 2100 UL RAM 2200 UL 1 50-005 10 Ga Zinc Plated Metal Chassis 1 1 1 2 3 50-018 Spring Load Bracket 1 1 1 50-020 6 1/4" Limit Switch Shaft 1 1 1 4 50-021 Polyethylene Cover 1 1 1 5 50-028 Speed Reducer Size 40/40:1 Gear Ratio 1 1 1 6 50-033 1/2 Hp 115 VAC Electric Motor 1 7 50-034 3/4 Hp 115 VAC Electric Motor 8 50-035 1
RAM 2000 UL - 2100 UL - 2200 UL RAMSET BILL OF MATERIAL FOR: RAM 2000 UL - RAM 2100 UL - RAM 2200 UL 20 ITEM PART # PART DESCRIPTION RAM 2000 UL 45 50-304 120/240 Intelligate Transformer 1 1 1 46 50-321 1/2" Hex Head Lock Nut 4 4 4 47 50-539 5/16" Socket Head Screw 5 5 5 48 50-770 Limit Switch Table Bracket 1 1 1 49 50-771 Reinforced Plate 1 1 1 50 50-772 Bullet Release 1 1 1 51 50-773 3/8" x 1" Hex Head Bolt 2 2 2 52 50-774 Switch Cover 1 1 1 53 50-7
RAM 2000 UL - 2100 UL - 2200 UL RAMSET GATE ENTRANCE SAFETY PRECAUTIONS 1. Never let children operate or play with gate controls. Keep the controls away from children. 2. The entrance is for vehicles only. Pedestrians should use a separate entrance. 3. Always keep people, children and objects away from the gate while the gate is in operation. No one should cross the area of a moving gate. 4.
RAM 2000 UL - 2100 UL - 2200 UL RAMSET TROUBLESHOOTING TABLE CONDITION SOLUTION POSSIBLE CAUSES NO LIGHTS ARE 'ON' 1. Circuit breaker popped. 2. 1/2 amp. fuse blown. 3. Power supply damaged on control Board. 1. Reset circuit breaker. 2. Replace 1/2 amp. fuse. 3. Return Control Board for repair. GATE MOVES A COUPLE OF FEET AND THEN REVERSES 1. E.R.D. too sensitive. 1. A) for 1/2 hp motors: turn dip switch "A" 4 'On'. "EXIT" L.E.D. IS ALWAYS 'ON' 1. Faulty accessory connected to the "Exit". 1.
RAMSET RAMSET OPTIONAL ACCESSORIES 20-05 RAMSET MOUNTING POST FOR ACCESS CONTROL 50-40 RAMSET REMOTE CONTROL TRANSMITTER RKLE RAMSET KEYLESS ENTRY SYSTEM RAMSET MAGNETIC LOCK RAMSET RADIO RECEIVER RAMSET KEY SWITCH BOX ILD-24 RAMSET PLUG-IN LOOP DETECTOR RAMSET FIRE BOX EMERGENCY ENTRY BOX RAMSET RPI BBS Provides back-up power for a 1/2 hp gate operator and accessories. For approx. 50 cycles. RAMSET BATTERY BACK-UP SYSTEM www.ramsetinc.
Opening the way… Important information for the homeowner Ask your technician about all the features of our new Ramset operator. Safety devices, such as reverse loops, phantom loops, photo eyes, or miller edges must be installed on your gate before the operator may be used. Ask your technician which safety devices best suit your safety needs. Read your warranty certificate and fill out your warranty extension card.
www.ramsetinc.