Owner's manual
16
DS1 Programming Switches
Factory settings are shown in bold italic type
1 Automatic close timer enable
ON Timer to close is activated (Safety accessories recommended if turned on)
OFF Timer to close is disabled
2 Timer to close will activate on limit only
ON Timer to close activates only if open limit is activated
OFF Timer to close works from any point the gate is stopped
3 Master Gate Enable
ON Master gate operator enabled to function
OFF Master gate operator disabled
4 Slave Gate Enabled
ON Slave gate operator enabled to function
OFF Slave gate operator disabled
5 Solenoid lock option
ON In addition to solenoid lock DS2, outputs 12vdc when gate is moving
OFF Disables 12vdc output when gate is moving
6 Soft stop open enable (Right hand installation, if switch 9 is on then close enable)
ON Enables soft stop for open position
OFF Disables soft stop for open position
7 Soft stop close enable (Right hand installation, if switch 9 is on then open enable)
ON Enables soft stop for extend position
OFF Disables soft stop for extend position
8 Stop circuit enable
ON Allows for a stop button input to be utilized
* a normally closed pushbutton is required
OFF Disables the stop button function
9 Operating Direction Reverse
ON Left Hand Slider installation (See note bottom page 11)
OFF Right Hand Slider Installation
10 Not used at this time
ON N/A
OFF N/A
Siren Output
OPEN/CLOSE
COMMAND
Vehicular Gate Operator
Gate Weight Max. Load: 650 lbs.
LED INDICATOR
S2
RESET
Entrapment
S
E
C
U
R
I
T
Y
S
H
U
N
T
C
O
M
M
O
N
G
N
D
M
A
G
L
O
C
K
S
O
L
O
N
O
I
D
L
O
C
K
C
O
M
M
O
N
G
N
D
O
U
T
P
U
T
+
1
2
V
O
N
2
3
4
1
SOLONOID LOCK ENABLE
MAGNETIC LOCK ENABLE
SECURITY SHUNT ENABLE
MOTION DETECTOR ENABLE
15
5
0
10
TIMER TO CLOSE
ADJUSTMENT
Timer
ADJUSTMENT
Class I or Class II per UL325
J2 INDICATORS
1- +12V OUT 1.5 AMP MAX
2- COMMON GROUND
3- PUSH BUTTON INPUT
4- OPEN SAFETY EDGE
5- CLOSE INPUT
6- SECONDARY ENTRAPMENT DEVICE INPUT
7- COMMON GROUND
8- STOP CIRCUIT INPUT N/C
9- FREE EXIT / OPEN INPUT
10- UNDER GATE / CENTER LOOP INPUT
11- SAFETY LOOP / REVERSING EDGE INPUT
12- MOTION DETECTOR INPUT
1 2 3 4 5 6 7 8 9101112
J2
BOTH ON FOR DUAL
DS1 SWITCH SETTINGS FACTORY SETTINGS
SW-1 AUTO CLOSE TIMER ENABLE OFF
SW-2 TIMER TO CLOSE WILL ACTIVATE ON LIMIT ONLY ON
SW-3 MASTER GATE ENABLE ON
SW-4 SLAVE GATE ENABLE OFF
SW-5 SOLENOID LOCK OPTION, SEE INST ALLATION MANUAL OFF
SW-6 SOFT STOP RETRACT ENABLE OFF
SW-7 SOFT STOP EXTEND ENABLE OFF
SW-8 STOP CIRCUIT ENABLE OFF
SW-9 OPERATING DIRECTION REVERSE OFF
SW-10 SOFT ST ART ENABLE FOR SW6 AND SW7
OFF
1
2
3
4
5
6
7
8
9
10
O
N
DS1
PATRIOT CONTROL BOARD
USAutomatic MADE IN USA
CURRENT SENSE
ADJUSTMENT
0
10
5
MASTER
Sensitivity
CURRENT SENSE
ADJUSTMENT
0
10
5
SLAVE
Sensitivity
15
Both must be on for dual gate operation