Manual
25
SAFETY SECTION
Remedies for Safety Concerns
Zone 3 Safety edges are the best protection. A photo eye may also be used. For vehicle
traffic, magnetic vehicle detectors and wire sensing loops are preferred.
Zone 4 This area is best protected with a photo eye wired to the secondary entrapment
input. The beam should be installed parallel to the gate in the open position or
along the obstructing wall or fence.
Zone 5 Safety edges and photo eyes are the most common types of protection available.
Every installation is unique and it is the installer's responsibility to recognize and remedy all safety
concerns. Please consult a qualified dealer, or the factory for a complete explanation of the remedies
shown above and additional tips pertaining to your installation.
Reflector Beam Photo Eye Unit 1 wire to Safety Loop input
Catch Post
U-Shaped Safety Edge Wired Safety Edges on bottom rail of gate. Wire to Secondary Entrapment
to Secondary Entrapment Input Input. (Do not allow edges to contact ground)
Reflector Beam Photo Eye Unit 2 wire to Safety loop input
Catch
Post
Photo Eye Unit wired to secondary
entrapment input
B W
E A Obstruction fence, wall etc..
A L
M L
Reflector
Reflector BEAM Photo Eye Unit wired to
Safety Loop input
Control box
Single or Dual Safety Edges wire to
Secondary Entrapment Input.
NOTE: When gates are fully closed, Safety Edges must not contact each other.
This can cause
f
alse obstruction sensin
g