FUNCTION OF PROGRAM SWITCH SETTINGS – DS1
DS1 Programming Dipswitches
Factory settings are shown in bold italic type
1 Automatic Close Timer Enable (Not recommended unless safety devices are installed)
ON Timer to close is activated (Adjustable from approximately 2 to 120 seconds)
OFF Timer to close is disabled
2 Open limit timer to close function
ON Timer to close activates only if open limit is activated
OFF Timer to close works from any point the gate is stopped
3 Master Gate Enable
ON Master gate operator enabled to function
OFF Master gate operator disabled
4 Slave Gate Enabled (Both Master and Slave on for dual)
ON Slave gate operator enabled to function
OFF Slave gate operator disabled
5 Solenoid Lock Option, (See Accessory Wiring page 35)
ON DS2 SW 1 must be on, output +12 vdc with delay when gate is operating
OFF No function, see DS 2 SW 1 page 18 for more information
6 Soft Stop Retract Enable
ON Enables soft stop for retract position
OFF Disables soft stop for retract position
7 Soft Stop Extend Enable
ON Enables soft stop for extend position
OFF Disables soft stop for extend position
8 Stop circuit enable * A normally closed pushbutton is required
ON Allows for a stop button input to be utilized
OFF Disables the stop button function
9 Operating Direction Reverse (must be on for push to open installations to operate correctly)
ON Push to Open
OFF Pull to Open
10 Not used at this time
Siren Output
OPEN/CLOSE
COMMAND
Vehicular Gate Operator
Gate Weight Max. Load: 650 lbs.
LED INDICATOR
S2
RESET
Entrapment
S
E
C
U
R
I
T
Y
S
H
U
N
T
C
O
M
M
O
N
G
N
D
M
A
G
L
O
C
K
S
O
L
O
N
O
I
D
L
O
C
K
C
O
M
M
O
N
G
N
D
O
U
T
P
U
T
+
1
2
V
O
N
2
3
4
1
SOLONOID LOCK ENABLE
MAGNETIC LOCK ENABLE
SECURITY SHUNT ENABLE
MOTION DETECTOR ENABLE
15
5
0
10
TIMER TO CLOSE
ADJUSTMENT
Timer
ADJUSTMENT
Class I or Class II per UL325
J2 INDICATORS
1- +12V OUT 1. 5 AMP MAX
2- COMMON GROUND
3- PUSH BUTTON INPUT
4- OPEN SAFETY EDGE
5- CLOSE INPUT
6- SECONDARY ENTRAPMENT DEVICE INPUT
7- COMMON GROUND
8- STOP CIRCUIT INPUT N/C
9- FREE EXIT / OPEN INPUT
10- UNDER GATE / CENTER LOOP INPUT
11- SAFETY LOOP / REVERSING EDGE INPUT
12- MOTION DETECTOR INPUT
1 2 3 4 5 6 7 8 910 11 12
J2
BOTH ON FOR DUAL
DS1 SWITCH SETTINGS FACTORY SETT INGS
SW-1 AUTO CLOSE TIMER ENABLE OFF
SW-2 TIMER TO CLOSE WILL ACTIVATE ON LIMIT ONLY ON
SW-3 MASTER GATE ENABLE ON
SW-4 SLAVE GATE ENABLE OFF
SW-5 SOLENOID LOCK OPTION, SE E INSTALLATION MANUAL OFF
SW-6 SOFT STOP RETRACT ENABLE OFF
SW-7 SOFT STOP EXTEND ENABLE OFF
SW-8 STOP CIRCUIT ENABLE OFF
SW-9 OPERATING DIRECTION REVERSE OFF
SW-10 SOFT START ENABLE FOR SW 6 AND SW7
OFF
1
2
3
4
5
6
7
8
9
10
O
N
DS1
PATRIOT CONTROL BOARD
USAutomatic MADE IN USA
CURRENT SENSE
ADJUSTMENT
0
10
5
MASTER
Sensitivity
CURRENT SENSE
ADJUSTMENT
0
10
5
SLAVE
Sensitivity
15
J5
1 2 3 4