Circuit Board Terminal Description For Accessories
Patriot Control Board
TERMINAL DESCRIPTION
1 + 12 vdc Output.
*Maximum current output 1.5 amp (1500 milliamps)
2 Common Ground Input
3 Push Button Input. (normally open contacts)
Push button, radio control, keypad, etc.
4 Open Safety Edge (normally open contacts)
(Stops gate when opening)
5 Close Input (normally open contacts)
6 Secondary Entrapment Input (normally open contacts)
7 Common Ground Input
8 Stop Circuit Input (normally closed contacts)
* DS1 switch #8 must be on for stop circuit function to be enabled.
9 Free Exit/Open Input (normally open contacts)
Loop input or any hold open input such as a 7-day timer, telephone access unit, or
maintain contact switch (normally open contacts). These devices open the gate and
will prevent the gate from closing if the contact is maintained. Once the contacts have
been released, the gate can be closed with a closing signal device or the automatic
close timer feature. Receiver relay 2 pre-wired for latching open.
10 Center Loop or Under Gate Loop Input (normally open contacts)
11 Safety Loop/Photo-eye/Reversing Edge Input (normally open contacts)
12 Motion Detector Input (normally open contacts)
(Stops a closed gate from opening)(Active on close limit only)
* DS2 Switch 4 must be on for Motion Detector function to be enabled
The Accessory connector is a plug, which can be
removed from the control board for ease of wiring
and troubleshooting purposes.
Place finger below connector and pull out to
remove.
Siren Output
OPEN/CLOSE
COMMAND
Vehicular Gate Operator
Gate Weight Max. Load: 650 lbs.
LED INDICATOR
S2
RESET
Entrapment
S
E
C
U
R
I
T
Y
S
H
U
N
T
C
O
M
M
O
N
G
N
D
M
A
G
L
O
C
K
S
O
L
O
N
O
I
D
L
O
C
K
C
O
M
M
O
N
G
N
D
O
U
T
P
U
T
+
1
2
V
O
N
2
3
4
1
SOLONOID LOCK ENABLE
MAGNETIC LOCK ENABLE
SECURITY SHUNT ENABLE
MOTION DETECTOR ENABLE
15
5
0
10
TIMER TO CLOSE
ADJUSTMENT
Timer
ADJUSTMENT
Class I or Class II per UL325
J2 INDICATORS
1- +12V OUT 1. 5 AMP MAX
2- COMMON GROUND
3- PUSH BUTTON INPUT
4- OPEN SAFETY EDGE
5- CLOSE INPUT
6- SECONDARY ENTRAPMENT DEVICE INPUT
7- COMMON GROUND
8- STOP CIRCUIT INPUT N/C
9- FREE EXIT / OPEN INPUT
10- UNDER GATE / CENTER LOOP INPUT
11- SAFETY LOOP / REVERSING EDGE INPUT
12- MOTION DETECTOR INPUT
1 2 3 4 5 6 7 8 9 10 11 12
J2
BOTH ON FOR DUAL
DS1 SWITCH SETTINGS FACTORY SETT INGS
SW-1 AUTO CLOSE TIMER ENABLE OFF
SW-2 TIMER TO CLOSE WILL ACTIVATE ON LIMIT ONLY ON
SW-3 MASTER GATE ENABLE ON
SW-4 SLAVE GATE ENABLE OFF
SW-5 SOLENOID LOCK OPTION, SE E INSTALLATION MANUAL OFF
SW-6 SOFT STOP RETRACT ENABLE OFF
SW-7 SOFT STOP EXTEND ENABLE OFF
SW-8 STOP CIRCUIT ENABLE OFF
SW-9 OPERATING DIRECTION REVERSE OFF
SW-10 SOFT START ENABLE FOR SW 6 AND SW7
OFF
1
2
3
4
5
6
7
8
9
10
O
N
DS1
PATRIOT CONTROL BOARD
USAutomatic MADE IN USA
CURRENT SENSE
ADJUSTMENT
0
10
5
MASTER
Sensitivity
CURRENT SENSE
ADJUSTMENT
0
10
5
SLAVE
Sensitivity
15
J5
1 2 3 4