User guide
1717
Board Harness Function
Pin 1 Orange Open Limit
Pin 2 White Close Limit
Pin 3 Black Motor (positive on open, negative on close)
Pin 4 Red Motor (negative on open, positive on close)
Pin 5 Green Common for both limit switches
Pin 6 Yellow Encoder Input from EIB module
Pin 7 Black Battery Negative
Pin 8 Red Battery Positive
1
3
5
7
2
4
6
8
Master/Slave Connector
Applies battery voltage directly to motor to open gate (will not close gate) if
control board fails. User must unplug before gate opens to maximum travel or
the 15 amp fuse will open. Fuse should be checked before returning gate to
service.
EMERGENCY BYPASS
12V Supplied battery voltage
SLV Slave Operator Indicator (indicates slave side of gate is closed)
+12V when on closed limit. Ground when off of closed limit.
MAS Master Operator Indicator (indicates master side of gate is closed)
+12V when on closed limit. Ground when off of closed limit.
GND Battery supplied ground (connects to GND on EIB module)
SIREN Connect to siren + (also connects to +12V on EIB module)
applies +12V when gate(s) are running, or in hard shutdown
GND Battery supplied ground
LOCK Connect to lock + (optional) Magnetic or Solenoid type locks (Dip Switch #6 Selectable)
Remote Outputs