OWNER’S MANUAL MODEL LA400 MEDIUM DUTY SWING GATE OPERATOR 2 YEAR WARRANTY Serial # Primary Arm Serial # Secondary Arm Serial # Box Installation Date
TABLE OF CONTENTS TABLE OF CONTENTS OPERATOR SPECIFICATIONS WARNING Tools Needed for Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Carton Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Additional Items Needed for Installation . . . . . . . . . . . . . . . . . . .3 Operator Dimensions and Specifications . . . . . . . . . . . . . . . . . . .3 UL325 Classifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CARTON INVENTORY HARDWARE KIT LA400 (K77-19130) DESCRIPTION Post Bracket Pull to Open Bracket Hex Bolt 5/16"-18 X 1-1/2" Square Neck Carriage Bolt 3/8"-16 X 6" Hex Nut 3/8"-16 Hex Nut 5/16"-18 Flat Washer 5/16" Flat Washer 3/8" Lock Washer 5/16" Lock Washer 3/8" Gate Mounting Bracket Hairpin Clip Pin Hex Bolt 3/8"-16 X 1-1/2" Bolt 2-3/4" CONTROL BOX LA400 (LA-CONTROL) QTY 1 1 5 2 5 5 5 5 5 5 1 4 2 1 2 DESCRIPTION Control Box Hardware Bag QTY 1 1 MISCELLANEOUS Linear Actuator Arm - Model LA400-1K (1) or
U L 3 2 5 M O D E L C L A S S I F I C AT I O N S The LA400 is intended for use with vehicular swing gates. The opener can be used in Class I, Class II and Class III applications. CLASS I – RESIDENTIAL VEHICULAR GATE OPERATOR A vehicular gate operator (or system) intended for use in a home of one-to four single family dwelling, or a garage or parking area associated therewith.
S A F ET Y I N S TA L L AT I O N I N F O R M AT I O N 1. Vehicular gate systems provide convenience and security. Gate systems are comprised of many component parts. The gate operator is only one component. Each gate system is specifically designed for an individual application. 2. Gate operating system designers, installers and users must take into account the possible hazards associated with each individual application.
S U G G E S T E D E N T R A P M E N T P R O T E C T I O N D E V I C E LO C AT I O N S SWING GATE SYSTEM Telephone Entry System STREET t up err Int Loop Photo Eye for Open Cycle m) 1.2ical ( ' 4 yp T ow ad Sh Loop Seal Loops 1-1/2" (37 mm) Loop Wire Layer 1/4" (6 mm) or larger depending on Loop Wire size t up err Int Loop Shadow loop should be positioned in direction of gate travel. Pull-to-open illustrated.
SAFETY PRECAUTIONS FOR SWING AND ORNAMENTAL "GRILL TYPE GATES" WARNING WARNING To prevent SERIOUS INJURY or DEATH from a moving gate: • Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate. • Locate entrapment protection devices to protect in BOTH the open and close gate cycles. • Locate entrapment protection devices to protect between moving gate and RIGID objects, such as posts. • A swinging gate shall NOT open into public access ways.
I N S TA L L AT I O N SINGLE GATE SETUP Post Bracket Assembly Gate Operator Antenna Warning Sign Control Box with Batteries 4-1/2' (1.4 m) Power Cable Earth Ground Installation (Optional, See Page 13) Gate Bracket 12 gauge wire PVC conduit (not included) to protect the power cable and low voltage wire from lawn mowers and string trimmer. 8 ft. (2.
PULL-TO-OPEN BRACKET MOUNTING INSTRUCTIONS NOTE: The mounting illustrations represent a typical installation using the provided gate hardware. The gate opener may also be installed by welding it to the gate structure. For push-to-open installation order accessory kit 50-19503. 1. Place pull-to-open bracket on top of the post bracket. Insert 3/8" hex bolt through middle hole and secure with lock washer, flat washer and nut. Insert 5/16" hex bolt through hole in pull-to-open bracket and post bracket.
5. Fasten gate bracket to the actuator side of the operator using pin. Swing operator to the desired open position (Figure 5). 6. Open gate to full open position (Do not exceed 100°). Adjust operator until it is level and position bracket against the cross member. Secure using C clamp (Figure 6). 7. Remove pins and detach operator. 8. Mark holes for post bracket assembly and gate bracket. Be sure to mark holes in the vertical center of post bracket slots.
4. Attach operator to gate post bracket by inserting push-to-open bracket into slot on the motor side of operator. Secure with pin (Figure 4). 5. Fasten gate bracket to the actuator side of the operator using pin. Swing operator to the desired closed position (Figure 4). 6. Position gate to full closed position. Adjust operator until it is level and position bracket against the cross member. Secure using C clamp (Figure 5).
CONTROL BOX MOUNTING 1. Remove PCB and batteries. 2. Determine the spacing required for mounting and select the proper holes to be used for mounting (Figure 1). 3. Knockout plastic from holes using screw driver. 4. Place box up against the mounting surface. Insert the screws through the mounting holes in back and secure in place (Figure 2). Mounting Post Figure 2 4" (10 cm) Screw Spacing (4) Figure 1 E-Box 6" (15 cm) Screw Spacing (4) Mounting screw 4 places 2-1/2" (6.
NING WARNING W IRING ION WARNING To reduce the risk of SEVERE INJURY or DEATH: • ANY maintenance to the operator or in the area near the operator MUST not be performed until disconnecting the electrical power and locking-out the power via the operator power switch. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service. • Disconnect power at the fuse box BEFORE proceeding.
WARNING CONTROL WIRING CAUTION P2 P1 CLOSE EDGE Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE R2Ø7 J1 NO Z2Ø R227 C K5 MAGLOCK To reduce the risk of FIRE or INJURY to persons, use ONLY Chamberlain part #K74-30762 for replacement batteries.
BASIC CONTROL BOARD SETUP 19 20 26 17 1 P2 R223 P1 CLOSE EDGE J19 Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE K6 ALARM 14 J1 NO Z2Ø R227 C K5 MAGLOCK 13 OPEN EDGE/ PHOTO NO L1 J18 S8 OFF OFF SINGLE NO NO LEARN XMITTER R1 10A 32V 2 GATE 1 1 2 3 4 5 Z1 O N 1 R2 ON ON DUAL NC NC Z22 R92 U4 SAVE MAGLOCK MODE EDGE PHOTO Z9 OPEN PHOTO S1 F3 3 R224 C NC 18 2 R2Ø7 4 R91 BRN D1Ø GRN R94 K2 Z8 WHT 12 CLOSE PHOTO DIAGNOSTIC YEL 5 R93 BLU GATE 1 RED K1 Q9 Z12 SET OPEN
SET DIP SWITCH FOR GATE TYPE 1. The Save switch must be set to the OFF position prior to setting or changing the switches. 2. Set switch to Single for single gate installation. For Dual (Gate 1 and 2) installation set switch on Dual. 3. Set the Save switch to ON to save the setting. NOTE: When setting switches S2-5, the Save switch must be in the OFF position prior to setting or changing switches for the change to be saved.
COMPATIBLE REMOTES - 315MHz PROGRAMMING REMOTE 1. Press LEARN XMITTER button (LED will light up). 2. Press remote button, the LED will flash, alarm output will activate twice. 3. Repeat steps 1 and 2 until all remotes are programmed (50 remotes maximum). NOTE: For highest level of security, we recommend the Security✚® line of products.
OPTIONAL CONTROL DEVICES SBC (Single Button Control) Input (N/O) This input will command the gate to OPEN / STOP / CLOSE / STOP in sequence. Reset Control Input (N/O) The control box has a factory installed internal reset button. These terminals are intended for use with a single reset button that is installed within line of sight of the gate. This input functions to reset the alarms. This input will NOT stop the gate. Open (N/O) - Opens only or reverses a closing gate.
LOOP INPUTS (P11) Shadow Loop Input Terminal and Common This input protects cars by preventing the gate from moving off of the open or close limit when the shadow loop input is active. Interrupt Loop Input Terminal and Common This input functions to reverse a closing gate to the open limit. Latching this input will reset the timer to close.
SAFETY ACCESSORIES FOR SECONDARY ENTRAPMENT PROTECTION The following devices are acceptable for Safety Accessories for secondary entrapment protection. These devices have been tested with the LA400 to meet the requirements of UL325 and UL991.
FORCE AND TIMER TO CLOSE FORCE CONTROL Set the force control such that the unit will complete a full cycle of gate travel but will reverse off an obstruction without applying an unreasonable amount of force. MIN MAX BI-PART DELAY Set the BI-PART DELAY to desired setting. The range is 0 to 8 seconds, 0 seconds is OFF. OFF TIMER TO CLOSE ENABLE Set the TIMER TO CLOSE to desired setting. The range is 0 to 180 seconds, 0 seconds is OFF. MAX OFF MAX PROGRAM LIMITS P2 R223 P1 1.
DIP SWITCH SETTINGS P2 R223 P1 CLOSE EDGE J19 Ø14GPØ89ØE Ø14LGØ89ØE Ø14SKØ89ØE K6 ALARM R2Ø7 J1 NO Z2Ø R227 C K5 MAGLOCK OPEN EDGE/ PHOTO NO L1 J18 C 2 GATE 1 OFF OFF SINGLE NO NO ON ON DUAL NC NC SAVE MAGLOCK MODE EDGE PHOTO S1 F3 U4 Z22 R92 OFF OFF SINGLE NO NO Z9 OPEN PHOTO R91 BRN D1Ø GRN R94 K2 Z8 WHT CLOSE PHOTO DIAGNOSTIC YEL R93 BLU GATE 1 RED K1 Q9 Z12 ACCESSORY POWER R9Ø SET OPEN LIMIT SET CLOSE LIMIT ON ON DUAL NC NC SAVE MAGLOCK MODE EDGE PHOTO S1
WARNING O P E R AT I O N A N D M A I N T E N A N C E IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of SEVERE INJURY or DEATH: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. NEVER let children operate or play with gate controls. Keep the remote control away from children. 3. ALWAYS keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. Test the gate operator monthly.
WARNING WARNING WARNING CAUTION To avoid SERIOUS personal INJURY or DEATH from electrocution, DISCONNECT electrical power to operator BEFORE proceeding. To reduce the risk of FIRE or INJURY to persons, use ONLY Chamberlain part #K74-30762 for replacement batteries. BATTERY REPLACEMENT 1. Disconnect power to operator. 2. Open the control box cover. 3. Remove all quick connect terminals in use to the control board. Remember location of all wire connections for reinstallation. 4.
L A 4 0 0 S W I N G G AT E A C C E S S O R I E S SOLKIT12V Solar Panel Kit with battery box: Improved solar solution with battery box (battery not included). 02101 1-Button Station: Steel enclosure wired station will allow for a Open, Close, Stop command of the gate. 377LM SECURITY✚® Keyless Entry: Enables homeowner to operate gate by entering a password on a specially designed keyboard. Also can add a temporary password for visitors or service persons.
WIRING DIAGRAM 1. ANTENNA INPUT 2. CLOSE EDGE 3. OPEN EDGE/PHOTO EYE 4. OPEN PHOTO EYE 5. CLOSE PHOTO EYE 6. 24VDC ACCESSORY OUTPUT 7. CONTROL INPUTS/EXIT LOOP 8. LOOP INPUTS, SAFETY/SHADOW 9. TRANSFORMER INPUT/SOLAR INPUT (OPTIONAL) 10. SECOND - OPERATOR ARM CONNECTION 11. 24VDC ACCESSORY OUTPUT 12.
TROUBLESHOOTING FAULT POSSIBLE CAUSE FIX OPERATOR IS DEAD When power is supplied to the control board, no LED turns ON. 1) Battery fuse is blown. 2) Battery or Run Transformer connection is loose. 3) Dead battery. 4) Bad control board. ➤ Replace battery fuse. Use only 20A, ATC style fuse. ➤ Check battery and transformer connections. OPERATOR DOES NOT RUN Unit does not respond to a Radio command. 1) Low battery. 2) Radio (remote) not programmed. 3) STOP button connection loose. STOP LED is OFF.
TROUBLESHOOTING FAULT GATE RUNS TOO SLOW GATE DOES NOT CLOSE AUTOMATICALLY POSSIBLE CAUSE FIX 1) Open and Close Limits are set too close together. ➤ If the Open and Close Limits are set within the ramp down distance of each other, the gate will run at slow speed all the time. 2) The gate is starting within the ramp down distance from the Open or Close Limit. ➤ Gate will run slow to limits if motion is started within the ramp-down distance from the limit.
REPAIR PARTS Refer to the parts lists below for replacement parts available for your operator. If optional modifications and/or accessories are included with your operator, certain components may be added or removed from these lists.
REPAIR PARTS ACTUATOR ARM KITS ITEM 1 2 3 4 Not Shown PART # DESCRIPTION 41ASWG-442SA 41ASWG-438SA 41ASWG-0014SA 41ASWG-489 41ASWG-0119 Release Lever Motor with Limit Switch Harness Rear Connector Cable 24V with Connector Release Key 2 1 3 4 30 QTY 1 1 1 1 1
O P E R AT O R N O T E S 31
WARRANTY POLICY AND SERVICE LIFTMASTER® TWO YEAR LIMITED WARRANTY The Chamberlain Group, Inc. warrants to the first retail purchaser of this product, for the structure in which this product is originally installed, that it is free from defect in materials and/or workmanship for a period of two years from the date of purchase. The proper operation of this product is dependent on your compliance with the instructions regarding installation, operation, maintenance and testing.