User Manual

Installation and Maintenance Manual
ii
Smart Touch Controller Menu Guide for StrongArm (HTG 320)
To gain access to the User Menu, press the Menu button when the gate is stopped. The LCD will scroll through key
several items, then stop at the close timer setting [Ct ].
User Menu Options Default Description
U1
0
0 = Close timer off or 1 99 seconds
U2
0
0 = momentary, 1= Constant hold PB required to close gate
U3
0
0 = momentary, 1= Constant hold PB required to open gate
U4
0
0 3 (0 =Type A, 1 = B, 2 = C, 3 = D) See handbook
U5
0
0 = Open only, 1 = Adds Close capability when fully open
U6
0
0 = none, 1 = Buzzer alerts 3 sec before & when in motion,
2 = Buzzer alerts 3 sec before + first 2 seconds in motion
U7
0
0 = disabled, 1 sound buzzer (2 pulses/sec) if forced
open for more than four seconds, time out in 30 Sec
U8
0
0 = disabled, 1 sound buzzer (2 pulses/sec) if drift closed
and cannot reopen within four seconds.
U9
0
0= off, 1 = on (auto reset to 0 when close limit triggered)
U10
0
0= display, 1= set mins, 2= set hours, 3= set day, 4= month
U11
5
1 - 9 = Adjusts contrast of the display
U12
0
0 = Std. 1 = Extended (reset to 0 in 24 hr) (V4.xx software)
Note for U6 The Warn before operate buzzer is an accessory device for StrongArm (HTG 320)
operator.
To access Installer Menu, press the Open & Reset buttons together while in the User Menu.
Installer Menu Options Default Description
I1
0
0 = Gate disabled, Set Class 1 through 4 use
I1a
0
0 = Buzzer not set, 1 = Freq 1, 2 = Freq. 2
I2
0
0 = User Settings, 1 = Load defaults (resets entire menu)
I3
0
0 = Solo operator, 1 = Slave unit, 2 = Master unit
I4
0
0 = DC + AC charger, 1 = DC + Solar charger
I5
0
0 = input disabled, 1 = enabled
I6
0
0 = input disabled, 1 = enabled
I7
3
1 = Maximum sensitivity, 9 = Lowest sensitivity
I8
0
1 = stop only (note, functions in usage class 4 only)
I9
0
0 = none (1-7) ½ second steps (Master/Slave only)
I10
0
0 = none (1-7) ½ second steps (Master/Slave only)
I11
0
0 = 60 Seconds max run, 1 = 300 Seconds max run
I12
0
0 = Close eye stops only, 1 = 2 sec reverse to open
I13
0
0 = Normally Open PE output, 1 = N.C. (Supervised mode)
I14
0
0 = Normally Open Edge output, 1 = Normally Closed
I15
1
0 = select Time Clock, 1 = select Open Interlock
I15a
0
0 = disable Free Exit, 1 = disable Close Timer
I16
1
0 = pause closing only, 1 = enable reversing to open
I17
1
0 = pause closing only, 1 = enable reversing to open
I18
0
0 = Reopen if tripped while closing, 1 = Pause only
I19
0
0 = One way, 1 = Bi-directional - disables ELD if tripped first
I20
0
0 = Std. Close, 1 = Count opens & closes after equal reset
I21
0
0 = Off, 1 = Enable ELD back off auto close feature
I22
1
0 = disabled, 1 24 = see relay output options page 26
I23
6
0 = disabled, 1 24 = see relay output options page 26
I24
1
0 = disabled, 1 24 = see relay output options page 26
I25
2
0 = 0 sec, 1= 15s, 2= 45s, 3= 75s, 4= 105s, 5= 135s
I26
3
0 = 0 sec, 1= 15s, 2= 45s, 3= 75s, 4= 105s, 5= 135s
I26a
0
0 = no network, 1-99 network ―drop‖ address
I27
0
0=Run, 1=show freq, 2=show call level 0-7, 3= set Freq 1-4
I28
0
0=Run, 1=show freq, 2=show call level 0-7, 3= set Freq 1-4
I29
0
0=Run, 1=show freq, 2=show call level 0-7, 3= set Freq 1-4
I30
0
0=Run, 1=show freq, 2=show call level 0-7, 3= set Freq 1-4