Installation and Reference Manual SwingRiser ™ 14, 19, 30 (HRG) Hydraulic swing gate operator with Smart Touch Controller 800-321-9947 • www.hysecurity.
June 6, 2012 HySecurity Upgrades Software: User Programmable Output Relays 800-321-9947 www.hysecurity.
Alert and Error Codes Display Code Error/Fault/Alert Description Buzzer Chirp Sequence Possible Cause & Suggested Corrective Action New Products from HySecurity AdvanceDrive™ Wheel System: XtremeDrive™ Option: 800-321-9947 www.hysecurity.
Manual addendum SwingRiser April 17, 2012 Page 21: D0121 Rev D Adjustment of the Flow Control Regulating Valve SwingRiser Flow Control Adjustment – For CLOSE Direction Only CAUTION: Before adjusting the flow control regulating valve, the SwingRiser posts must be installed, plumbed and wired to the HydraSupply. The gate must be secured on the posts with its index arm attached, adjusted and tightened. 800-321-9947 www.hysecurity.
800-321-9947 www.hysecurity.
HySecurity® Gate – Quick Start Instructions For HRG Swing Gates These instructions are provided as a quick reference guide to the experienced installer that is already familiar with all safety precautions and the installation of this gate operator. Do not attempt to install from this guide if you are inexperienced with this product. 1. Use four ⅝-inch to ¾-inch anchor bolts to mount the 12-inch square operator base. Provide a 1-inch clearance from the backing post or the wall.
Installation and Maintenance Manual Smart Touch Controller Menu Guide for Swing Gates To gain access to the User Menu, press the Menu button when the gate is stopped. The LCD will scroll through key several items, then stop at the close timer setting [Ct ].
HySecurity Gate Operators SWINGRISER SWING GATE Operators With Smart Touch Controller Installation and Maintenance Manual SwingRiser (HRG 220 ST) SwingRiser Twin (HRG 222 ST) and UPS (DC Battery Backup) Models D0121, Rev.
Installation and Maintenance Manual Hydraulic Swing Gate Operator With Smart Touch Controller ©Copyright 2010 HySecurity Gate Inc. All rights reserved. No part of this manual may be reproduced by any means: photocopier, electronic or mechanical, without the express written permission of HySecurity Gate Inc. Additionally, HySecurity Inc. makes no representations or warranty with respect to this manual.
Installation and Maintenance Manual Table of Contents Introduction ...................................................................................................................... v Warranty Registration ..................................................................................................... vi Available Models and Features ....................................................................................... 1 I. Safe Gate Design Important Information .................................
Installation and Maintenance Manual Table of Contents, continued Installing Gate Reversing Edge (Contact Type) Sensor ............................................ 39 Installing Photoelectric (Non-Contact) Sensor ................................................... 40 - 41 IV. Detectors and Loops Loop and Detector Installation Guide.................................................................. 42 - 43 Loop Layouts ..........................................................................................
Installation and Maintenance Manual Introduction Welcome – We would like to take this opportunity to thank you for this purchase. HySecurity has manufactured the finest hydraulic gate operators available since the 1970s. Our commitment to quality and innovation will become evident as you become familiar with the features and performance of this expertly engineered machine. All HySecurity operators are equipped with the Smart Touch Controller, a digital electronic brain that offers unparalleled features.
PRODUCT & WARRANTY REGISTRATION Enter the following information to register your HySecurity product. Please write legibly. Today’s Date:_____________________ NOTE: To extend the operator warranty beyond 1 year, you must return this registration within 60 days of purchase. Refer to the Limited Warranty.
Installation and Maintenance Manual Available Models and Features HySecurity manufactures twelve different models of hydraulic swing gate operators to suit the size, weight and desired speed of the gate panel. All of the operator models are derived from the standard HRG 220, which is the basis of this manual. Take a moment to identify the operator model you have and note there are some changes in the instructions, especially in regards to final adjustments of double swing gates.
Installation and Maintenance Manual Available Models and Features The Smart Touch Controller (Standard) This is the brain of the all HySecurity’s automatic operators. Truly high technology, but is also very rugged to reliably serve in the harsh environments that exist in the real world. The Smart Touch Controller is also very smart and can quickly be configured by an installer or user to adapt to almost any functional requirement of a specific site.
Installation and Maintenance Manual Safe Gate Design READ THIS FIRST! Important Information – Review Before Installation Automatic gate operators provide convenience and security to users. However, because these machines can produce high levels of force it is important that all gate operator system designers, installers and end users be aware of the potential hazards associated with improperly designed, installed or maintained systems.
Installation and Maintenance Manual Install an Automatic Swing Gate Operator Only When: The gate moves freely in both directions. Never over-tighten a clutch or pressure relief valve to compensate for a stiff moving gate. The operator will not swing the gate into a public access area. The operator will be properly electrically grounded and the intended supply voltage matches the voltage label on the operator. The operator controls will be located in a clear line-of-sight to the gate.
Installation and Maintenance Manual Important Information For Gate System Owners & Users WARNING: To reduce the risk of serious injury or death, read and follow all instructions in the gate operator handbook and on the warning labels. Save These Important Owner and User Instructions: (Installers – be certain to instruct the owners and users about the following items) Automatic gates are for vehicular use only! Provide walkways and signs to direct pedestrians to a separate walk-through entrance.
Installation and Maintenance Manual Scope and Planning Installation Putting it all together: sample plans The type and location of sensors needed for proper swing gate operation depends primarily on whether the gate opens perpendicular to a wall (Fig. C) or opens to an open space (Fig. D) Fig. C A swing gate that opens parallel to a wall or building. This figure illustrates a sample plan for a gate, incorporating the elements described below. 1. The swing gate operator automates the gate.
Installation and Maintenance Manual Putting it all together: sample plans Fig. D A swing gate that opens to empty space This figure illustrates a sample plan for a gate, incorporating the elements described below. 1. The swing gate operator automates the gate. It may be ordered for left hand or right hand as shown. 2. The weather resistant NEMA 3R controller box houses the Smart Touch control and hydraulic pump. 3. An entrance control opens the gate for entry. 4.
Installation and Maintenance Manual Tools Required for an Efficient Installation 8
Installation and Maintenance Manual Swing Gate Post Details 9
Installation and Maintenance Manual Swing Gate Post Details – continued 10
Installation and Maintenance Manual Swing Gate Post Details – continued 11
Installation and Maintenance Manual HRG 220 - Pump Pack 12
Installation and Maintenance Manual HRG 222 Pump Pack 13
Installation and Maintenance Manual How Our Hydraulic Swing Gates Work 14
Installation and Maintenance Manual Installation Preparation Checklist 1. Read all of the instructions, especially the Important Information at the beginning of this manual, before you attempt installation. This section is focused upon mechanical installation. For electrical setup, skip to the section on system configuration and use of the Smart Touch Controller. 2. Check to see that the mounting slab is the right size and ready to have an operator attached.
Installation and Maintenance Manual Field Hose Measurements for HRG Operators Note: HRG operators are usually shipped without the hoses needed to complete the system. HySecurity will make these hoses in custom lengths as required, attach the quick disconnect fittings and pre-charge the hoses with hydraulic fluid. The use of pre-charged hoses is important to avoid the introduction of air into the system. When field measuring for the necessary hose length to order, the following may be helpful: 1.
Installation and Maintenance Manual Detailed Installation Instructions for HRG Swing Gate Operator 1) Mount control box and connect all conduit fittings. a) Mount controller box within 100ft (30m) of the gate operator, preferably within 20ft (6m). If installing the DC version of the operator, mount the battery power supply very near the controller enclosure because of the high current demand by the DC motor – See the Two Part operator section.
Installation and Maintenance Manual 3) Typical conduits required at the control panel a) High voltage wires: (120, 208, 240) single phase or (208, 240, 480) three phase, or 24VDC from Batteries. Refer to Wiring and Control Configuration for DC Operators. NOTE: 120 VAC not available on 2HP models b) 2‖ conduit (with swept elbows) to the hydraulic post(s) for hoses. c) 3/4‖ conduit to the post(s) for limit switches.
Installation and Maintenance Manual Mounting the Gate Panel, Index Arm, and Lock Pin Assembly 1) Mount the gate panel with six 3/8-inch bolts through both sides of the 11-inch hinge. Be sure to provide the correct clearance between the gate and the road surface. See the illustration on page 9. Allow 3-inches of clearance at the far end of the gate panel. See illustration below. 2) Measure and mark where the index arm bracket will be situated along the lower horizontal member of the gate.
Installation and Maintenance Manual 10) Mount the locking pin mechanism on the lower corner of the free end of the gate panel in such a position that the pin penetrates 2 inches into its lock receptacle when the gate is fully closed. 2” 11) Bury the receptacle tube in the roadway so it acts as a socket for the locking pin.
Installation and Maintenance Manual Adjustment of the Flow Control Regulating Valve HRG Swing gate operators employ the use of a flow control valve to control the closing speed of the gate. The flow control valve is the small rectangular brass device with the knurled adjusting knob, located just above the red quickdisconnect fitting for the hydraulic hose.
Installation and Maintenance Manual 22
Installation and Maintenance Manual Smart Touch Set Up Basics of Using the Smart Touch Controller Read this page if you are unfamiliar with using the Smart Touch Controller. The installation and commissioning of any HySecurity Gate Operator requires the setting of 1 or more menu settings within the Smart Touch Controller before an installation can be completed. Many other control settings or function changes can be made to configure the operator for your specific needs.
Installation and Maintenance Manual b. Press the Program Menu button and watch the LCD scroll the system data, or press the Program Menu key a 2nd time to skip the scroll. c. The LCD display scroll will stop at the menu item for the auto close timer setting [Ct __]. This is the first item in the User Menu. d.
Installation and Maintenance Manual Wiring Control Inputs to the Smart Touch Controller 1. Test the basic open and close operator function before wiring the external control inputs. This makes it easier to troubleshoot if an unexpected function issue arises. 2. Each input has an LED to indicate when that input is active. a. On Classic ST Controllers, to disclose the input status, the LED button must be pushed and held. This button is in upper left corner near the Stop input. b.
Installation and Maintenance Manual New Generation Smart Touch Board Runs software 4.xx and higher.
Installation and Maintenance Manual Connecting a Master / Slave Pair The HRG 222 is automatically programmed to operate as a master slave set. If you are installing two HRG 220’s to operate as a Master/Slave pair, the process is very simple. There is no need to order a special model or any adapters. The area of the board marked Dual Gate employs a 3-wire RS485 serial port for communication between Master and Slave operators. 1.
Installation and Maintenance Manual Smart Touch Controller Menu for Hydraulic Swing Gates Initial Power Up – When power is turned on, the display will disclose the software revision: Display Revision Number 2s delay Displays software version Number, ex. [h3.02] System Data and accessing the User Menu Settings: If the gate is stopped in normal mode, pressing of the Menu button accesses the User Menu. After the menu button is pressed, the LCD will scroll the system data in the table below.
Installation and Maintenance Manual Smart Touch Controller Installer Menu Functions The Installer Menu can be accessed only by entering the User Menu first, and then by pressing the Reset button and the Open button simultaneously. To restore the factory default settings, go to menu item [Fd_0] and change the setting to 1, then press the Program Menu button. The entire menu will reset to the factory defaults.
Installation and Maintenance Manual Description of Functions Available in the User Menu User 1 [Ct _] Close timer setting: This menu item is the automatic close timer for the gate. The factory setting is zero, which is off. It may be configured up to 99 seconds. User 2 [hC 0] Momentary Close: This menu item is to configure for the system for constant hold push button Close function. The factory setting is zero, which is momentary contact input.
Installation and Maintenance Manual Description of Functions Available in the Installer Menu Installer 1 [uC 0] Set UL Usage Class: This menu item is used to set the UL usage class, which must be set by the installer before the operator will function. Installer 2 [bu 0] Select Buzzer Type: This menu item selects the type of audible buzzer installed on the machine. To set, push SELECT on the keypad, the display will flash 0, push OPEN and note the buzzer volume. Push OPEN again and note the buzzer volume.
Installation and Maintenance Manual Description of Functions Available in the Installer Menu Installer 16 [Sr 1] IES (inherent sensor) reverse to open: The default for this menu item is for a 2 second reversal if the inherent sensor is triggered. The optional setting of [Sr_1] will cause the gate to reopen fully if triggered while closing. Installer 17 [PC 0] Set PEO/ PEC – NO/NC: The default for this menu item is for photo eyes with Normally Open outputs.
Installation and Maintenance Manual Optional Wiring If alternate output functions are required, see Options for User Programmable Output Relays 1-3. NOTE: User 3 is rated for DC only up to 48VDC and does not have a NC connection. Connecting an Interlocked Pair: An interlocked pair of operators is not a Master/Slave system, but is simply two gate operators interlocked such that the one cannot open unless the other is fully closed.
Installation and Maintenance Manual Options for User Programmable Output Relays 1-3 The Smart Touch Controller can interface with several types of external devices through the use of its programmable output relays. All of the output functions listed below are accessible in the Installer Menu under the selection [r1 __], [r2 __] and [r3 __]. Select which relay you wish to use and enter the appropriate function by the numbers as listed below. Note: The User Relays will operate normally to less than 18VDC 1.
Installation and Maintenance Manual 20. Free Exit Loop Vehicle Detector (ELD) output (available with h3.23 and higher software): This output is active whenever the ELD is tripped. 21. Inside Obstruction Vehicle Detector (OOLD) output (available with h3.23 and higher software): This output may be used to interlock to an exit device to prevent pedestrian use. This output is active whenever the IOLD is tripped. 22. Shadow Loop Vehicle Detector (SLD) output (available in h3.
Installation and Maintenance Manual Entrapment Protection Device Schematic for Swing Gates This schematic view is not meant to recommend the only way to set up your configuration, but to point out the various elements of a proper automatic vehicular gate installation. The gate operator itself is only the one component in the total system. Always install a separate pedestrian gate.
Installation and Maintenance Manual Gate Operator Category Horizontal Slide, Vertical Lift, Vertical Pivot Swing and Vertical Barrier (arm) Usage class Primary typea Secondary typea Primary typea Secondary typea Vehicular I and II A B1, B2, or D A, or C A, B1, B2, C, or D Vehicular III A, B1, or B2 A, B1, B2, D, or E A, B1, or C A, B1, B2, C, D, or E Vehicular IV A, B1, B2, or D A, B1, B2, D, or E A, B1, C, or D A, B1, B2, C, D, or E Note—The same type of device shall not be utilized
Installation and Maintenance Manual Placement and Use of Secondary Pedestrian Entrapment Sensors WARNING: To reduce the risk of serious injury or death, read and follow all instructions in the gate operator handbook and on the warning labels. Automatic gate operators are intended only for vehicular use and pedestrians must be routed to a separate man gate, however sensors are still required in order to provide a degree of protection should anyone happen to stray into the area of an automatic gate.
Installation and Maintenance Manual Installing Gate Reversing Edge (Contact Type) Sensor 1. Follow the guidelines in the Entrapment Protection Schematic to plan the most appropriate mounting positions for the edge sensors to be installed. For swinging gates. one or more contact sensors (edge sensors) shall be located on the inside and outside leading edge, and on the bottom edge of a swinging gate that has more than 6‖ clearance to the road.
Installation and Maintenance Manual Installing Photoelectric (Non-contact) Sensors General Information: Follow the guidelines in the Entrapment Protection Schematic to plan the most appropriate mounting positions for the photo-eye sensors to be installed. If there are no other secondary external entrapment protection sensors (typically an edge sensor), at least two photoelectric sensors are required to serve to reverse the gate in each direction of travel.
Installation and Maintenance Manual Installing Photoelectric (Non-contact) Sensors (continued) Supervised Connection: If the photo eye being installed has a true NC output (one that is NC when the photo eye is powered, aligned and set for Light Operate) then a supervised connection is recommended. A supervised connection will signal a system Fault and prevent gate operation if either the open or close photo eye connection ever becomes an open circuit or a short circuit.
Installation and Maintenance Manual Detector Installation Guide Detector Basics The vehicle detector passes a small current flow through the ―loop‖ which then becomes an inductive coil. When a vehicle passes over a loop the detector senses the resultant drop in the inductance, and actuates the detector output. Loop Configurations Configurations differ depending on the application. In parking applications with our HTG 320 operator, a loop may be as small as 3’ x 6’.
Installation and Maintenance Manual Detector Installation Guide, continued 9. Follow this guide for the correct number of wire turns according to the perimeter size of the loop: 10 to 13 lf. = 5 turns 14 to 26 lf. = 4 turns 27 to 45 lf. = 3 turns 46 to 100 lf. = 2 turns 10. This guide is written from a design perspective, but installation workmanship practices are equally important to insure proper operation and long loop life.
Installation and Maintenance Manual Loop Layouts 44
Installation and Maintenance Manual Loop Layouts, continued NOTE: A MINIMUM OF THREE (3) DETECTORS ARE REQUIRED FOR THIS TYPE OF GATE.
Installation and Maintenance Manual Vehicle Detector Installation Options The Smart Touch Controller provides a feature rich interface to four different vehicle detector inputs. Standard box type 11 pin (24 Volt DC or 24 Volt AC) vehicle detectors may be connected in the traditional manner.. HySecurity also offers a custom mini detector module that plugs directly into the Smart Touch Control board. Not only is the field installation much faster, but there is also a large performance benefit.
Installation and Maintenance Manual HySecurity Hy-5A Vehicle Detector Installation 1. Insert the locking end of each of two 1‖ long white plastic standoffs into the mounting holes on the detector. 2. Plug the detector into the appropriate socket along the right side edge of the Smart Touch Controller board for the detector function that is desired. Be careful to align the six detector pins into the socket correctly, and then snap the standoffs into the holes on the right side of our control enclosure. 3.
Installation and Maintenance Manual Standard 11 Pin Box Type Vehicle Detector Installation 1. If standard 11 pin vehicle detectors are to be used, snap up to three sockets onto the aluminum DIN mounting rail, with the key in the center hole facing to the left. 2. Both 24 Volts AC or DC are available, so either detector voltage may be used. (24 VAC is not available if the operator is a battery type) 24 VAC is available at the spade terminals on the lower left corner of our power supply (marked ACC).
Installation and Maintenance Manual Vehicle Detector & Loop Fault Diagnostics If HySecurity HY-5A mini detector modules are used, the Smart Touch Controller has ability to store and report detector and loop fault information for performance diagnostics.
Installation and Maintenance Manual 24Hr / 7 Day Time Clock Option This is an option you can order from HySecurity. The timer generates an open command which will hold the gate open until it is released. Instructions on how to use and program it accompany the timer.
Installation and Maintenance Manual Troubleshooting Trouble With Gate Movement in General: 1. Review the HRG index arm adjustment and the flow control valve adjustment. 2. Inspect the operator for hydraulic leaks both in the control panel and the base of the operator post, insure there is sufficient fluid in the reservoir, if not refill it to within 1‖ of the fill plug. 3. During operation listen for unusual sounds and investigate the source.
Installation and Maintenance Manual "The gate panels move in the wrong direction." 1. Check hose connections to verify the correct order red to red and brass to brass. 2. With the system engaged to open, verify that the Open Valve coil develops a strong pull. (This can be tested by removing the nut retaining the coil and grasping the coil) "The gate only opens or only closes." 1. If the gate only opens, the directional valve may be stuck and need cleaning or replacement. 2.
Installation and Maintenance Manual Troubleshooting The Smart Touch Controller system includes many self diagnostic capabilities. The LCD will display specific messages and the Audio Alert buzzer will sound distinctive chirps. Any Alerts, Faults or Errors are also logged into a memory and stamped with a time and date. For diagnostic purposes, these messages can be retrieved with optional WinLogger software available from HySecurity Gate.
Installation and Maintenance Manual General Maintenance The reliable design of the SwingRiser Operator significantly lowers ongoing maintenance issues. However, certain aspects of the operator and gate need to be inspected on a regular basis. These aspects are addressed in this section and include: the operator post the hydraulic system the electrical controls NOTE: No lubrication is needed for any part of the operator, including the cam followers in the center of the operator.
Installation and Maintenance Manual Reshimming the Bearings To add shims, you need to order the Shim Kit. It includes four 0.020 and four 0.060 shims. Refer to the HySecurity Price Book for the appropriate part number. Important aspects to consider when you are shimming bearings: One half of the bearing is usually worn more than the other. Use different shim thicknesses (0.020 or 0.060) to keep the inner tube centered inside the post.
Installation and Maintenance Manual 6. Force the shim pack into the space between the worn bearing (A) and the square post. If the gap between the inner tube and the bearings (both portions A and B) remains higher than 0.020-inches, loosen the screws that secure portion B and force equal-sized shim packets between bearing (B) and the outer post. IMPORTANT: Keep the bearings centered and maintain a consistent gap around the diameter of the inner tube.
Installation and Maintenance Manual Important aspects to consider when you are replacing bearings: Locate the weld seam inside the square post. It should run along the side that is attached to the gate hinges. The notched portion of the bearing half must be installed so that the notch aligns with the weld seam. If the weld seam is not evident inside the post, place the bearing so the notch is on the hinge side. Hinge ¼ -20 cap screw holes Weld seam Shims are inserted at the factory with 0.0 to 0.
Installation and Maintenance Manual 5. Alleviate the possibility of the bearing falling into the post’s interior by using two self-tapping screws and some string. Fasten a separate strand to each screw. Turn the screw into each half of the UHMV plastic bearing until each screw is secure. 6. Remove the four screws in the outer post that hold the worn half of the bearing in place. Pull on the string to remove the bearing from inside the post, and then perform the same step for the other half of the bearing.
Installation and Maintenance Manual Bleeding Air from SwingRiser Hoses using the Bleeder Tool Assembly Air trapped in the hydraulic systems of SwingRiser (HRG) operators can cause slow and/or jerky operation. In SwingRiser Twin (HRG 222) systems (two gate panels operating from a single hydraulic supply), air can prevent the two panels from synchronizing.
Installation and Maintenance Manual 9. Turn on the power to the hydraulic supply. 10. Press OPEN or CLOSE to run the motor and pump hydraulic fluid through the hoses. Run the pump for the length of time determined in Step 8. NOTE: The operator will shut off due to the ―maximum run timer‖ after 1-minute. If needed, press RESET on the keypad and restart the operator (in the same direction) to complete the bleeding process. When the air has been bled from the hoses, take the following steps: 1.
Installation and Maintenance Manual Pressure Relief Valves Adjustment Procedures To check your relief valve setting, first disconnect the hoses. Run the operator either open or closed (the gate will not move with the hose disconnected. The relief valve is found on the rear of the hydraulic power unit. It has an adjusting head and lock nut. To adjust, loosen the lock nut and screw the threaded bolt clockwise for increased pressure, counterclockwise to decrease pressure.
Installation and Maintenance Manual Special Notes: *1 Your gate will usually require more maintenance than the HySecurity operator that is moving the gate. Damaged or warped gate panels are signs that a vehicle may have hit the gate. Verify that the actuator post is not also damaged. *2 Normally, with correct operator speed, the actuator post should need very little attention.
Installation and Maintenance Manual IMPORTANT SPECIAL NOTES REGARDING D.C. POWERED GATE OPERATORS The on/off switch on the electric control panel of the drive unit does not disable all DC power to the operator, even if the AC power has been disabled at its source. The large rotary switch in the DC power supply enclosure must be actuated off to insure disconnect of all DC power to the drive unit. The disconnect in the power supply must be off if the AC source power will be absent for more than one week.
Installation and Maintenance Manual Wiring and Control Configuration for DC Operators If this installation is a 24-Volt DC battery type gate operator, there are a few additional steps that must be completed before the system can be functional. Review the installation instructions below and the Battery Connection Diagram. Be certain the DC power disconnect switch is turned off before making any connections. 1.
Installation and Maintenance Manual Battery Connection Diagram Connect six wires to the gate operator as shown. Install batteries as show, observing polarity: Four 14 gauge wires to the control circuit. Always connect red wires to (+) and black wires to (-). The exception is Connect from lug terminals to DC motor: Two 6 gauge minimum for 1hp operators Two 2 gauge minimum for 2hp operators the jumper wire which connects the two batteries.
Installation and Maintenance Manual APPENDIX For ½-hp through 5-hp motors Supplying a gate operator with the right electrical service is crucial to the way the performance of the operator the life of its electrical components. If the wire size used is too small, the voltage loss—especially during motor starting—will prevent the motor from attaining its rated horsepower. The percent of horsepower lost is far greater than the percentage of the voltage loss.
Installation and Maintenance Manual 67
Installation and Maintenance Manual Parts Breakout – SwingRiser Single (HRG 220) Pump Packs (1Ø ONLY) For an up-to-date parts list and numbers, refer to the HySecurity Price Book. For more information, refer to the www.hysecurity.com website.
Installation and Maintenance Manual Parts Breakout – SwingRiser Twin (HRG 222) Pump Packs (1Ø ONLY) For an up-to-date parts list and numbers, refer to the HySecurity Price Book. For more information, refer to the www.hysecurity.com website.
Installation and Maintenance Manual Parts Breakout – Control Box For an up-to-date parts list and numbers, refer to the HySecurity Price Book. For more information, refer to the www.hysecurity.com website.
Installation and Maintenance Manual Parts Breakout – Post For an up-to-date parts list and numbers, refer to the HySecurity Price Book. For more information, refer to the www.hysecurity.com website.
Installation and Maintenance Manual Parts Breakout - DC Power Supply Battery charger Terminal, 2-Pole Circuit Breaker Vent 30A Fuse Block with a 5A Fuse 30A Fuse Block with a 15A Fuse Switch, Disconnect Terminal, 5-Pole Two 12V Batteries Battery Enclosure for two batteries For an up-to-date parts list and numbers, refer to the HySecurity Price Book. For more information, refer to the www.hysecurity.com website.
Installation and Maintenance Manual Smart Touch Controller Connections 73
Installation and Maintenance Manual 74
Installation and Maintenance Manual 1. Warranty. THESE ARE THE ONLY WARRANTIES GIVEN BY HYSECURITY AND ARE IN PLACE OF ALL OTHERS. Hy-Security Gate, Inc. (―HySecurity‖) warrants that at the time of sale each of its products will, in all material respects, conform to its then applicable specification and will be free from defects in material and manufacture.
Installation and Maintenance Manual Copyright Notice © Copyright 2010 by HySecurity Gate Inc. All rights reserved. No part of this manual may be reproduced by any means (photocopier, electronic, or mechanical), without the express written permission of HySecurity Gate Inc. Federal Copyright law prohibits the reproduction, distribution, or public display of copyrighted materials without the express written permission of the copyright owner, unless fair use or other exemption under copyright law applies.