CVX-1468 Wiring Diagram and Quick Reference DataBender® Universal Data Converter WD-CVX-1468 v1.
External connections and product description 1-D0/CLK Input 2-D1/Data Input 3-Aux2 LED Out 4-Ground 5-RS232 Input 6-RS232 Output 7-RLY1 N.C. 8-RLY1 Com 9-RLY1 N.O. 10-RLY2 N.C. 11-RLY2 Com 12-RLY2 N.O. Converter CVX-1300 1-D0/CLK Output 2-D1/Data Output 3-Aux1 LED In 4-Analog In1 5-Analog In2 6-+5 VDC Out 7-RS485 (-) 8-RS485 (+) Diagnostic LED 1-Ground 2-8 to 16 VDC In Note: Terminals shown for reference. Connections may or may not be utilized based on converter function.
CVX-1468 Description The CVX-1468 includes all of the CVX-1300 converter functions. Refer to the CVX-1300 manual for the operational details and settings of those functions. DIP Switch coding of the CVX-1300 functions is logically opposite of those given in the CVX-1300 DIP Switch Table (Reverse the ON and OFF positions from those given in the table). CVX-1468 Specific Information for each additional setting: The CVX-1468 is a specialized converter for Transcore data conversion functions.
CVX-1468 Function QuickReference Settings specific to the CVX-1468 DIP Switch settings for the 1368 functions have changed Old 1368 Setting (if exists) / New 1468 Setting Setting #120 Wiegand HID40 to WPS serial Input Wiegand 40b: XXXXFFFFFFFFFFFFBBBBBBBBBBBBBBBBXXXXXXXX 12b FC, 16b Badge Output Serial: 000000FFFFFBBBBB Setting #1 / Setting #121 Wiegand 33b to WPS serial Wiegand Input = PFFFFFFFBBBBBBBBBBBBBBBBBBBBBBBBP Serial Output = 0000000FBBBBBBBB Facility code is decoded as 3 digit
Wiring Diagram - Serial to Wiegand (Typical Connections) CYPRESS Data0/Clock Out Data1/Data Out Data0 Data1 Access Control Panel Ground Ground RS232 Input Data Bender® (-) Ground +8 to +16 VDC In Connections to Serial Device DB-9 Connections Direct to PC Com Port CVX Terminal Page 5 of 8 DB9 Pin Ground 5 RS232 Input 3 (+) DC Power Supply
Wiring Diagram - Wiegand to Serial (Typcial Connections) CYPRESS Data0 Data1 LED Ground Card Reader D0/Clock In D1/Data In LED Out Ground RS232 Input RS232 Output Data Bender® (-) Ground +8 to +16 VDC In Connections to Serial Device (+) DB-9 Connections Direct to PC Com Port CVX Terminal DB9 Pin Ground 5 RS232 Input 3 RS232 Output 2 Reader Power Not Shown Supply power to reader according to reader supplier specifications. The CVX-1468 only requires Data and Ground connections to the reader.
CVX-1468 Converter Setting Quick Reference Converter Input Output Settings(#) Old 1368 / New 1468 HID40 Wiegand 40 Serial WPS 16 120 SW02232 Wiegand 33 Serial WPS 1 / 121 CVX-1399B Serial / Wiegand 26 Bit Wiegand 35 / 122 SW02231 Serial Transcore 37 Bit Wiegand Special 68 / 123 CVT-9165A Transcore,Transcore 26 Wiegand 26 86 / 124 CVT-9165B Transcore 26 Wiegand 34 Cardkey 87 / 125 CVT-9165A_88 Transcore/Transcore 26 37 Bit Wiegand 88 / 126 Page 7 of 8
DIP Switch Application Table # DIP SWITCH SETTING INPUT 1 2 3 4 5 6 7 8 Interface 96 97 98 X 99 X X 100 X 101 X X X X X X X X 102 X X X X 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 X X X X X X X X X X X X X X X Format X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X OUTPUT