User Manual

43
ON
514
GDE
ON
514
GDE
ON
514
GDE
ON
514
GDE
ON
514
GDE
ON
514
GDE
MASTER/SLAVE CONNECTION
Use a two wire and run it through a UL listed conduit for
master/slave connection. Follow the wiring diagram as shown below.
shielded cable
Master Board Slave Board
+.....................Positive to Positive...................+
-...................Negative to Negative...................-
Before connecting master/slave gate operators together, test and adjust limit
switches and the ERDs for each operator as “ ” machines. All
accessories must be installed on the master board, no exception.
the
stand alone
See page 53 for dip switch settings.
Connect shield to
slave metal frame
only.
Use UL listed
conduit
Shielded
cable