ATIC GATE OPER ATO TOM RS U A ® SLI DS DER HEA S • SW R E V O I N G ER S • SW-350 SW-300 Swinger Instruction Manual ® US L I STED UL325 compliant UL991 compliant Copyright C 2007 all-o-matic inc. www.allomatic.net WWW.ALLOMATIC.
TABLE OF CONTENTS Important safety instructions............................................................. 3 Different UL 325 class types........................................................ 5&7 Concrete pad installation for SW-300................................................8 Concrete pad installation for SW-350................................................9 Operator & Arm Installation.................................................11, 13&15 Compact Installation for SW-300 & SW-350.............
IMPORTANT SAFETY INSTRUCTIONS WARNING To reduce the risk of injury: READ THE FOLLOWING DIRECTIONS. DO NOT EVEN THINK OF STARTING UNTIL YOU HAVE READ AND UNDERSTAND THESE DIRECTIONS. IF THERE IS SOMETHING YOU DO NOT UNDERSTAND CALL US. Never let children operate or play with gate controls. Keep the remote control away from children. Always keep people and objects away from the gate. No one should cross the path of the moving gate. This operator must be tested monthly.
INSTALL THE GATE OPERATOR ONLY WHEN YOU HAVE READ THE FOLLOWING: *Confirm that the gate operator being installed is appropriate for the application. *Confirm that the gate is designed and built according to current published industry standards. *Confirm that all appropriate safety features and safety accessory devices are being incorporated, including both primary and secondary entrapment protection devices. *Make sure that the gate works freely before installing the operator.
DIFFERENT UL 325 CLASS TYPES Class one: Residential A vehicle gate operator intended for use at a home of one to four single family dwellings, garages or parking area. Class Two: Commercial or General Public Access A vehicular gate operator intended for use at a commercial location or building such as a multifamily housing unit (five or more single family units), hotel, garages, retail stores, other buildings servicing the general public.
CIMIENTO DE CONCRETO PARA EL CONCRETE PAD FOR SW-300 Cubierta plástica del operador Operator plastic Cover Tornillo de anclaje 4 lugares ½”X3 ½” Four red head Bolts 1/2” X 31/2” 24” 133/4” Chasis del operador Operator frame Cimiento de concreto para el operador Operator Concrete Pad 514 GDE ON 514 GDE 9” 24” ON Area for Conduit(s) Area para las pipas de conducto 2200 uF 2200 uF 2200 u ON 514 GDE 00 uF 1 B O UR N S3 38 6 -----------------------OPEN------------------------ 3 1 2 3 4
CIMIENTO DE CONCRETO PARA EL CONCRETE PAD FOR SW-350 Cubierta plástica del operador Operator plastic Cover Tornillo de anclaje 4 lugares ½”X3 ½” Four red head Bolts 1/2” X 31/2” 24” 9” Chasis del operador Operator frame 211/2” Area for Conduit(s) Area para las pipas de conducto Cimiento de concreto para el operador Operator Concrete Pad 30” Instalar 4” sobre la tierra cuándo sea posible When possible Install 4” above Ground 141/2” 17 1/4 ” 4” Cimiento de concreto para el operador Footing for Gate
OPERATOR AND ARM DIMENTIONS HINGE CENTER A POST OUTSIDE This distance is from the gate in open position to edge of the pad. Refer to note. INSIDE 2” B C Refer to note below. SE CO ND AR Y PR IM AR Y CONCRETE PAD Dimentions Chart Gate length Less than 12” A B C Minimum Distance 36” 35” 14” 34” 13’-15’ 42” 41” 14” 37” 16’-22’’ 48” 47” 14” 40” A: Is the distance between the gate bracket and the gate hinge point.
OPERATOR AND ARM LAYOUT Hinge point “A” Out Point Y In X Mark ground under gate bracket with gate closed. This will be point Y Bracket Bracket Point Z X 1 Mark ground under gate bracket with gate open. This will be point Z 14” Bracket Hinge point Out In X Point Y 2 Bracket Point Z X Draw a line from point Y past the point Z as shown. This should be laid on the ground. The operators center shaft goes on this line.
ARM LAYOUT & OPERATOR PLACEMENT CONTINUED Bracket Hinge point Point Y X 3 Bracket Point Z X Measure distance from the point Y And point Z. Say distance is 60”, divide this number by 2,which =30”. This is the length of primary arm in next drawing. PLEASE BE EXACT!!! Center shaft of Operator This ARM section is half the distance between point Y and point Z as shown above. IT MUST BE EXACT!!! This pipe does not need to be measured after primary arm is installed this pipe makes up the balance of arm.
SWINGER COMPACT INSTALLATON To use this installation the gate must be 12’ or less. HINGE CENTER 27” OUTSIDE INSIDE 8” 35” SE CO ND AR Y Use these measurements, only if the distance between the wall and the gate in the open position is 20” to 34”. If you have more than 34” refer to standard installation.
TORQUE LIMITER AND ARM ADJUSTMENT The torque limiter is shipped loose (not adjusted). You must use a 20” pipe wrench to adjust the large torque limiter nut on the operator as shown in the images below. Tighten torque limiter nut until arm does not slip when the operator is running. Also run gate and grab gate at mid cycle to make sure torque limiter will slip. This is an important adjustment, so please take your time and do it right. Torque limiter adjusting nut.
GATE TRAVEL ADJUSTMENT Locate limit switch. Step 1: Turn the power off on operator. Step 2: Use an allen wrench to loosen up the limit cams. Turn the limit Cams to desired direction. Step 3: tighten the allen screw. Step 4: Turn the operator back on. Step 5: Run gate operator. If more adjustment is needed, repeat the steps.
LEFT HAND OPENING SETTINGS 514 GDE ON 514 GDE ON 514 GDE 514 GDE ON ON 514 GDE ON 514 GDE ON ON 514 GDE See chart below for specific operator model wiring direction. . Motor wires SW-300 Use these wire settings for SW-300 & SW-350 opening direction IMPORTANT: This setting is for left hand opening. Be sure to follow the wire sequence as the C-LIMIT = Blue wire two Swinger models O-LIMIT = Red wire are the opposite of each other.
RIGHT HAND OPENING SETTINGS 514 GDE ON 514 GDE 514 GDE ON ON 514 GDE ON 514 GDE ON 514 GDE ON ON 514 GDE See chart below for specific operator model wiring direction. . Motor wires SW-300 Use these wire settings for SW-300 & SW-350 opening direction IMPORTANT: This setting is for right hand opening. Be sure to follow the wire sequence as the two Swinger models are the opposite of each other.
ELECTRICAL CONNECTION OPERATORS MUST BE PROPERLY GROUNDED! DANGER ELECTRIC SHOCK HAZARD DISCONNECT POWER BEFORE SERVICING UNIT SUITABLE FOR OUTDOOR USE ONLY OFF WARNING OFF THIS UNIT MUST BE INSTALLED AND SERVICED BY CERTIFIED TECHNICIAN. THIS UNIT WILL OPEN AND CLOSE WITHOUT WARNING Power switch and electrical connection box. For power wires enclosure use UL listed conduits. Connect black wire to 115 volts AC = Hot. For power, a minimum of a 20-Amp dedicated circuit breaker is needed.
SWINGER LOOP LAYOUT Outside Safety loop 5 FT WIRED IN SERIES 5 FT 5 FT Center Phantom loop 5 FT Gate in open position Inside Safety loop 1 1/2 IN 5 FT TWISTED 6 TURNS PER FOOT 1/4 IN 5 FT Exit loop WHEN USED This is a normal loop layout. Remember when connecting to an All-O-Matic circuit board you use the normally closed contacts for your safety loop detector and normally open contacts from the exit loop.
ACCESSORY CONNECTIONS C C 514 GDE ON 514 GDE 514 GDE ON ON 514 GDE ON 514 GDE ON 514 GDE ON ON 514 GDE The circuit board 24-VAC output provides up to 700 mAmps of power for accessories. More than two or three accessories will require a separate power supply. Remove black jumper from SAFETY when a safety device is installed. Power Detect 2 1 0 1 2 0 3 OFF 4 PRES 5 2 6 SENS. LEVEL 1 BOOST ON C PULSE 0 Loop Fail Power EXIT Loop Detector 0 FREQ.
MULTIPLE SAFETY DEVICES CONNECTIONS Multiple SAFETY devices installed together must be connected “in series”. Locate the normally closed (N.C.) dry contact from each accessory relay. Also, before installing the accessory devices, remove the black wire jumper from the SAFETY terminal position on the terminal strip of the control board. Safety wire connections From Accessory #1 to Terminal Strip From Accessory #2 to Terminal Strip Relay Com to 24V-COM Relay N.C.
LEADING EDGE CONNECTION 514 GDE 514 GDE B O UR 38 6 B O UR N S3 514 GDE N S3 38 6 ON B O UR ON N S3 38 6 ON 3 1 3 1 3 2200 u 1 514 GDE 514 GDE ON 2200 uF PHILIPS 514 GDE 514 GDE 2200 uF ON PHILIPS ON 00 uF ON 514 GDE ON 514 GDE ON 3 4 5 6 7 514 GDE ON 8 514 GDE ON EDGE ON 2 514 GDE ON GND 514 GDE 1 -----------------------OPEN------------------------ Connect one of the wires from leading edge to GND connector on control board.
PRE-WIRED LOOP INSTALLATION ON SW-350 Model SW-350 provides three pre-wired loop harnesses one for SAFETY LOOP one for PHANTOM and one for EXIT LOOP. Loop detectors must be 120 VAC. To install loop detectors make sure power is off in main power source then simply plug detector in designated harness socket and wire the ground loop to the grey and brown wires located inside the electrical box behind operator gearbox.
EMERGENCY RELEASE For SW-350 Procedures to release gate: 1. Turn power OFF. 2. Push pedal down & move pedal slightly to the right to hold pedal down in position. 3. Push gate open.
THREE BUTTON STATION SYSTEM 514 GDE ON 514 GDE ON 514 GDE ON 514 GDE ON 514 GDE ON 514 GDE ON ON 514 GDE See push button connections below. Terminal strip PED-SW Jumper Connect the COMMON from all the push buttons to 24V- COM on the terminal strip. OPEN N.O. CLOSE Connect OPEN push button N.O. contact to EXIT LOOP on the terminal strip. N.O. STOP COM N.C. Connect CLOSE push button N.O. contact to 3BT on the terminal strip. Connect STOP push button N.C.
MASTER/SLAVE CONNECTION Before connecting master/slave gate operators together, test and adjust the limit switches and the ERDs for each operator as “stand alone” machines. All accessories must be installed on the master board, no exception. See page 53 for dip switch settings. Use a two wire shielded cable and run it through a UL listed conduit for master/slave connection. Follow the wiring diagram as shown below. Master Board Slave Board +.....................Positive to Positive...................+ -..
MAGNETIC/SOLENOID LOCK CONNECTIONS Magnetic lock installation requires a step down transformer with appropriate voltage for the specific lock accessory. SOLENOID LOCK 514 GDE ON 514 GDE ON 514 GDE ON 514 GDE ON 514 GDE ON 514 GDE ON ON 514 GDE AC-N and LOCK from terminal strip supply 110 volts to power the transformer and control the locks’. Connect low voltage wires from transformer directly to the lock as shown below. Only two wires needed for the installation. No relay wires required.
RADIO RECEIVER CONNECTIONS 3 wire receiver mounts on receiver strip outside control box as shown below. 4 wire receiver :connect the two grey wires to 1 & 2 terminals on receiver strip outside control box. Connect black wire to 24 V-COM and red wire to 24VAC on main control board terminal strip as shown below. 514 GDE ON 514 GDE ON 514 GDE ON 514 GDE ON Multi-Code 3 wire 24VAC Radio Receiver 3 = 24V 2 = Relay 1 = Common 3 2 1 Receiver terminal strip located outside control box.
OPEN AND CLOSE ELECTRONIC REVERSING SENSOR(ERDs) ADJUSTMENT Open and Close ERD SENSITIVITY MAX MIN MAX MIN 514 GDE 3 3 2200 u 1 RNS BO U BO U B O UR ON 1 514 GDE 514 GDE 2200 uF 1 ON 2200 uF ON PHILIPS PHILIPS 3 1 3 38 6 3 3 38 6 38 6 B O UR RNS N S3 514 GDE N S3 38 6 B O UR ON N S3 38 6 1 3 514 GDE 00 uF ON 514 GDE ON 514 GDE ON 514 GDE 1 ON 2 3 4 5 6 7 514 GDE 8 -----------------------OPEN------------------------ ON 514 GDE ON 514 GDE ON Counter cl
TIMER ADJUSTMENT TIMER ON: Timer to close, can be set from 1 to 60 seconds. TIMER OFF: Gate operation is push button to open, push button to close. TO OVERRIDE THE TIMER: Turn the RADIO switch to the “ON” position. This will allow the radio receiver to close the gate before the timer. TIMER adjustment 0 60 Sec Sec 0 60 Sec Sec Turn potentiometer counter clockwise for more time. Turn potentiometer clockwise for less time. Timer Pot 60 Sec. 1 Sec.
DIP SWITCH FUNCTIONS OFF 1 2 3 4 TIMER TIMER switch “ON” activates the TIMER. See page 51 for details. RADIO RADIO switch “ON” allows the radio receiver to override the timer. See page 51 for details. 5 6 7 8 -----------------------OPEN------------------------ TIMER RADIO OSC LOCK 1-PASS SLAVE BRAKE SPARE ON OSC OSC switch “ON” allows the radio receiver to stop and reverse the gate in any direction. During a cycle the first signal stops gate, a second signal reverses gate.
SWINGER ARM PARTS 3 SET SCREWS PIPE KNUCKLES QUICK RELEASE ARM PIPE ARM 3 SET SCREWS GATE BRACKET HUB PRIMARY FLAT BAR ATIC GATE OPER ATO TOM RS AU SLI DS DER HEA S • SW INGERS • OVER 54 ®
ALL-O-MATIC’S good service and high quality by years of, proven reliability place the ALL-O-MATIC Swing gate operators ahead of the competition. The SW-350 is our highest duty rated operator and the most powerful continuous duty operator available in the market today. The SW-350 has a foot pedal release in the event of a power failure. The SW-300 is our most popular gate operator. It is continuos duty for light commercial and residential use.