Series 9150 Installation/Owner’s Manual Vehicular Slide Gate Operator Use this manual for circuit board 4602-010 Revision A or higher. 9150-065-Q-3-11 Convenience Open Optional WA R NI NG MO SE VIN RIO G US GAT Op er IN E C an ate JU AN d fre ga RY C e ofte on Do OR AUS pe ly wh op or not all le en DE E an ga op d ob te AT erat ow e gachild H struarea Do is te. ren ctio in pa not st to ns sig th play . ht wh and in ile in ga Re ga ga te te te ad area is pa ow mov th ne r’s ing.
SPECIFICATIONS Use this manual for the Model 9150 operator with circuit board 4602-010 Rev A or higher ONLY. Class of Operation Type of Gate Drive Sprocket Size Cycles Per Hour Speed Entrapment Protection Horsepower - Voltage - Phase Model 9150 - UL 325 Class I, II, III, IV Vehicular Slide Gates Only #40 Chain 60 Per Hour (Installed level). Approximately 1 Ft. per Second (Installed level).
TABLE OF CONTENTS SPECIFICATIONS ASTM 2200 Standard for Gate Construction Important Safety Instructions Instructions regarding intended installation: Important Notices UL325 Entrapment Protection Glossary Slide Gate Requirements Slide Gate Protection SECTION 1 - INSTALLATION 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.
TABLE OF CONTENTS SECTION 4 - ENTRAPMENT AND SAFETY PROTECTION 27 4.1 UL 325 Terminal Description 4.2 Secondary Entrapment Protection Device Locations 4.3 Loop Detector Wiring 27 28-29 30 SECTION 5 - WIRING 5.1 5.2 5.3 5.4 Main Terminal Description Control Wiring for Single/Primary Operator Auxiliary Device Wiring Bi-Parting Gates Wiring - Dual Gate Operators SECTION 6 - OPERATING INSTRUCTIONS 6.1 AC Power and Reset Switch 6.
ASTM F2200 Standard for Gate Construction Vehicular gates should be constructed and installed in accordance with ASTM F2200; Standard Specification for Automated Vehicular Gate Construction. For a copy of this standard, contact ASTM directly at 610-832-9585; service@astm.org; or www.astm.org. Important Safety Instructions WARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with gate controls. Keep the remote control away from children.
• For gate operators utilizing contact sensors: 1. One or more contact sensors shall be located where the risk of entrapment or obstruction exist, such as at the leading edge, trailing edge, and post mounted both inside and outside of a vehicular horizontal slide gate. 2. One or more contact sensors shall be located at the bottom edge of a vehicular vertical lift gate. 3. One or more contact sensors shall be located at the pinch point of a vehicular vertical pivot gate. 4.
UL 325 Entrapment Protection Class I Class II A vehicular gate operator (or system) intended for use in a home of one-to four single family dwelling, or a garage or parking area associated therewith. A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units) hotel, garages, retail store or other building servicing the general public.
Glossary GATE - A moving barrier such as a swinging, sliding, raising, lowering, or the like, barrier, that is a stand-alone passage barrier or is that portion of a wall or fence system that controls entrance and/or egress by persons or vehicles and completes the perimeter of a defined area. RESIDENTIAL VEHICULAR GATE OPERATOR – CLASS I - A vehicular gate operator (or system) intended for use in a home of one-to four single family dwelling, or garage or parking area associated therewith.
Slide Gate Requirements The operator is intended for installation only on gates used for vehicles. Pedestrians must be supplied with a separate access opening. The pedestrian access opening shall be designed to promote pedestrian usage. Locate the gate such that persons will not come in contact with the vehicular gate during the entire path of travel of the vehicular gate. (ref. UL 325 56.8.4.b) Adjacent fence that covers open gate position.
Slide Gate Protection Entrapment protection devices are required to reduce the risk of injury. Install sensors where the risk of entrapment or obstruction exists while gate is moving. Individual requirements will vary. Contact Sensor (Reversing Edges) A Installed on the fence to help minimize the potential of Warning Signs 2 Fence entrapment between the gate and fence. A filler post or barrier may need to be installed between fence and gate.
SECTION 1 - INSTALLATION Prior to beginning the installation of the slide gate operator, we suggest that you become familiar with the instructions, illustrations, and wiring guide-lines in this manual. This will help insure that your installation is performed in an efficient and professional manner compliant with UL 325 safety and ASTM F2200 construction standards. The proper installation of the vehicular slide gate operator is an extremely important and integral part of the overall access control system.
1.3 Typical Gate Types The Model 9150 operator is designed to be installed on these gate types. See the next 4 pages for specific operator mounting positions. Individual installations and physical stops can vary. • • • • 1500 lb. max. weight per gate (1 HP). Single Operator - 45 ft max. gate length (1 HP). Dual Operators - 90 ft max. total gate length (1 HP). Chain tray recommended for gates longer than 20 ft using front or center post mount installations ONLY. ver e l nti a C . wn .
1.4 Operator Mounting Positions The Model 9150 operator is designed to be installed in the front, rear, center or ceiling mounting positions shown on this page and the next 3 pages. V-wheel V-rail ornamental gates are shown as examples but other gate types on the previous page can use the same mounting setups. Once the mounting position has been determined, the chain idler wheels may need to be adjusted BEFORE the operator is mounted.
Rear Position with Concrete Pad Hides the chain from outside the property looking in. Chain Setup • Set one chain Idler wheel at the top and one in the center position on one side of the operator. • Remove both chain knockouts from one side of the operator. • Chain stops or gate end retainer can be used as the physical stop for the gate (Chain stops are shown). Chain Idler Wheels Chain Stop Additional hardware required.
Center Position with Post Mount Hides the chain from outside the property looking in. Optional chain tray kit can be used and is recommended for gates over 20 ft, supports the chain’s weight and helps prevent chain “stretching”. See page 19 for more information. Chain Setup • Set operator chain idler wheels in the bottom position. • DO NOT remove chain knockouts. Chain Idler Wheels Additional hardware required. Post base plate (P/N 2600-495) 6 x 6 steel posts not available from DoorKing.
Front or Rear Position Upside Down Can be mounted on the ceiling to conserve floor space. Ceiling • Operator’s setup is the same as the front position or rear position with concrete pad shown on page 12 and 13. (Front upside down position shown here). • Junction box connection is used for the ceiling mount installation. Chain Setup Chain Stop Chain Idler Wheels Note: There are NO fluids in the operator that can leak out.
1.6 Pad, Post or Ceiling Mount without/with J-Box Setup Pad Mount with Conduit 1” minimum from operator housing to gate. 2.5” Conduit Area Concrete pad MUST be level. 14.5” 8.5” 4” min. above ground. Electronic Box 21.5” Center 26” Concrete Pad Concrete Pad Underground depth of the concrete pad is determined by soil conditions and local building codes. Reinforced concrete recommended. Conduit Post Mount with Conduit Conduit area inside 6 x 6 post. Conduit area inside 6 x 6 post. 1.5” 14” Min.
1.7 Mounting Operator and Chain Prior to mounting the operator, be sure that the correct chain knockouts have been removed and chain idler wheels are in the correct position (top, center or bottom). Fail-Secure Manual Release Kit Installation Note: It is easier to install the 2600-865 fail-secure manual release kit before mounting the operator and attaching the chain. Refer to the instruction sheet supplied with the kit for installation.
Endless Idler Assembly (On Select Installations) DoorKing offers an endless idler assembly with a protective cover designed for the Model 9150 installations (P/N 2600-818). Make sure the endless idler assembly is securely fastened to the wall or post (Depending on which type of installation will be used). Extreme force will be exerted on this assembly during gate cycling.
1.9 Chain Tray Kit Installing the Chain Tray Kit A chain tray is recommended for gates longer than 20 ft. to support the weight of the chain. DoorKing offers a chain tray kit in sections to fit any length gate. (DoorKing P/N 2601-270 10 Ft. section) Chain Tray Supporting Bracket (Facing up) 10 Ft. Carriage Bolts Se gm ent Weep Hole Chain Tray Segments Connection 10 Ft.
SECTION 2 - AC POWER TO OPERATOR(S) Before attempting to connect any wiring to the operator, be sure that the circuit breaker in the electrical panel is in the OFF position. Permanent wiring must be installed to the operator as required by local electrical codes. It is recommended that a licensed electrical contractor perform this work.
2.2 High Voltage Terminal Connection • Route incoming AC power wire through the high voltage conduit and run wire in the operator as shown. • Be sure wiring is installed in accordance with local codes. Be sure to color code all wiring. • It is recommended that a surge suppressor be installed on the high voltage power lines to help protect the operator and circuit board from surges and power fluctuations. • Dual operators (Primary/Secondary) require AC power to each operator.
SECTION 3 - ADJUSTMENTS The switch settings and adjustments in this chapter should be made after your installation and wiring to the operator(s) is complete. Whenever any of the programming switches on the circuit board are changed, power must be shut-off, and then turned back on for the new setting to take effect. Every time the 9150 is powered up, the First open command will automatically run “Multiple gate cycles” that will locate and remember the gate’s open and close positions (See page 25). 3.
3.2 DIP-Switch SW 1 and SW 2 Settings The two DIP-switches located on the circuit board are used to program the operator to operate in various modes and to turn on or off various operating features. Whenever a switch setting is changed, power to the operator must be turned OFF and then turned back on for the new setting to take affect. Check and review ALL switch settings prior to applying power to the operator.
3.2 Continued SW 2 (Right 8 Switches) Switch Function 1 Exit Loop Port Output Setting Jumper Wire Needed Full Open Input 2 Stops Gate Partial Open (14 Ft) 4 Built-in Solenoid Lock 5 Operator Model Select 6 Quick-Close Timer Override 7 and 8 Gate Close Back-Off Position OFF A plug-in exit loop detector plugged into the EXIT Loop port will partially open single operator or fully open dual operators depending on type of loop detector used). ON Normal Setting.
3.3 Automatic Open / Close Limit Adjustment The 9150’s open/close limits DO NOT have to be physically adjusted. Every time the 9150 is powered up, the first open command will automatically run “Multiple gate cycles” that will locate and remember the gate’s open and close positions. These positions are determined by the physical stops that have been installed (See section 1.2, page 10).
3.4 Clutch Adjustment In addition to the inherent reverse sensor, this operator is equipped with a mechanical slip clutch (UL 325 Type C) to further reduce the possibility of injury should an entrapment occur. DO NOT over tighten the clutch to compensate for a gate that is damaged, poorly constructed or too heavy. Over tightening the clutch would create a hazard which could result in serious injury or death to persons who may become entrapped.
SECTION 4 - ENTRAPMENT AND SAFETY PROTECTION Secondary Entrapment Protection Devices: In addition to the inherent reversing sensor system, the Model 9150 has a 5-pin UL 325 terminal for the connection of photo sensors-Type B1 and reversing edges-Type B2 secondary entrapment protection devices required by UL 325 standards. Entrapment protection devices must be installed to reduce the risk of injury. Install these devices where the risk of entrapment or obstruction exists while the gate is moving.
4.2 Secondary Entrapment Protection Device Locations Typical UL Photo Sensor mounting height and distance away from gate. If the distance between the gate and wall is greater than 2 1/4”. Secure Side Non-Secure Side Inside Property Outside Property 5” or Less Gate Frame Reversing Edge (Open Contact Sensor) UL sensor mounted on wall. Gate Frame UL sensor mounted on post. 5” or Less Filler Post or Barrier Wall 21” Typical Photo sensors may be installed on either side of gate frame.
Wireless Reverse Edge Sample Setup - Single Receiver 9 V battery operated transmitter mounted on gate. Edge Transmitter Normally Open Filler Post Note: Install reversing edges on all the gate support posts or filler post in this area (e.g. cantilever gate installations, See below). Normally Open Common Wall Filler Post (If necessary) Opening-Direction Reversing Edge (If filler post is used).
4.3 Loop Detector Wiring To help protect the operator from accidentally closing on vehicles in the gate’s path, DoorKing highly recommends that loops and loop detectors be installed. Loops are laid underneath, cut into asphalt or concrete driveways or buried beneath gravel and earth driveways. A loop detection system will sense a vehicle like a metal detector and send a signal to the gate operator preventing the gate from automatically opening or closing on a vehicle when it is in the gate’s path.
SECTION 5 - WIRING 5.
5.2 Control Wiring for Single/Primary Operator Important: Controls must be far enough from the gate so that the user is prevented from coming in contact with the gate while operating the controls. Outdoor or easily accessible controls should have a security feature to prevent unauthorized use. Wiring opening device when using Relay - #2 - Full Open.
5.3 Auxiliary Device Wiring Blue Alarm Reset Terminal Red Alarm Output Terminal White Common Terminal Remote Alarm Reset Station (DoorKing P/N 1404-080 Only) MUST be mounted in the line-of-sight of the gate operator. 1 2 3 4 5 KEY SWITCH 6 7 8 9 4602 10 11 12 13 14 15 Gate Tracker (Quad Box Shown) DoorKing Access Control System (Model 1833, 1835, 1837 or 1838) tracker system can be connected.
5.4 Bi-Parting Gates Wiring - Dual Gate Operators • Separate power source for photo sensors (See page 27). Secondary Entrapment Protection Devices for Bi-Parting Gates Closing Non-Contact Sensor To Close Photo #2 Fence Filler Post if necessary (See page 8 for more information). Opening Contact Sensor Gate To Close Photo #2 Fence Opening Contact Sensor Filler Post if necessary (See page 8 for more information).
SECTION 6 - OPERATING INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS WARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with gate controls. Keep the remote control away from children. 3. Always keep people and objects away from gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. Test the operator monthly. The gate MUST reverse on contact with a rigid object or stop or reverse when an object activates the non-contact sensors.
6.2 Shutdown Conditions Under various entrapment conditions the operator will assume either a soft or hard (alarm) shutdown. To determine what type of reset action is required, you will need to understand how the different entrapment conditions affect the gate operator. Soft Shutdown This occurs in various situations where the inherent or secondary entrapment protection devices have been activated.
Resetting a Hard Shutdown The operator is in a hard shutdown condition when the audio alarm is sounding OR “chirping” every 5 seconds. • Before resetting a hard shutdown, determine why the shutdown occurred. Inspect the gate for any obstructions along its path that could have activated the inherent entrapment sensing system. Inspect the gate and gate hardware. The audio alarm will sound for five minutes, or until the operator’s reset button is pushed.
Fail-Secure Manual Release System (Owner Installed) This manual release system (Installed 2600-865 Fail-Secure Manual Release Kit) allows the gate to be manually operated ONLY after unlocking the gate operator. Power outages or turning power off WILL NOT allow gate to be manually operated without physically unlocking the gate operator with the key first. This option is typically used in Class III and Class IV applications.
SECTION 7 - OPTIONAL CONVENIENCE OPEN ADJUSTMENTS The optional convenience open system installed in your vehicular gate operator is designed as a convenience enhancement only. It is not designed or intended to provide continuous gate operation during a power outage. Its sole purpose is to provide a method to open the vehicular gate to allow unimpeded traffic flow when the gate and access control system is without power.
7.2 DC System Description Gate will automatically OR be manually OPENED and STAY open during an AC power failure. DIP-Switch 3 setting will determine how operator will return to normal operation once AC power has been restored.
SECTION 8 - MAINTENANCE AND TROUBLESHOOTING Inspection and service of this gate operator by a qualified technician should be performed anytime a malfunction is observed or suspected. High cycle usage may require more frequent service checks. T NO tch DO e clu ov e. rem plat 8.1 Maintenance When servicing the gate operator, always check any secondary (external) reversing devices (loops, photocells, etc.) for proper operation.
8.2 Troubleshooting Have a good VOM meter to check voltages and continuity. A Meg-Ohm meter capable of checking up to 500 meg-ohms of resistance is necessary to properly check the integrity of the ground loops. When a malfunction occurs, isolate the problem to one of three areas: 1. the operator, 2. the loop system, 3. the keying devices. Use caution when checking high voltage terminals, motor capacitor and the motor. 1. Check the input indicator LEDs.
Symptom Gate opens a short distance, then stops and reverses. Gate opens but will not close. Gate closes but will not open. Possible Solution(s) • • • • Check that the clutch is adjusted properly and is not slipping. Disconnect the gate from the gate operator and check that the gate slides freely without any binding. Re-adjust the reverse sensitivity. Check that the magnetic pickup transistors on control board are not obstructed by excess wires.
8.3 Accessory Items The following accessory items are available for the model 9150 slide gate operator. Contact Sensors - For use as a secondary entrapment protection device. Miller Edge, Inc., MGO20, MGR20, MGS20 Photo Cell - Non-contact (photocell) sensors for use as a secondary entrapment protection device. MMTC, Inc. Model IR55 - P/N 8080-010 MMTC, Inc.
Model 9150 1/2 HP 115 VAC 50uf Capacitor Blue Motor Resistors 1 Ohm 1 Ohm Blue 30 Watt 1/2 HP Motor Red Red 30 Watt Ground Built-In Solenoid Lock White Black MOV Assembly White Chassis Ground 115 VAC Hot Neu Neu Hot Hot Brown Alarm Black Black Red White White Yellow White Reset Neutral Power AC Power Convenience Outlets 1 2 3 4 5 REVERSE LOOP EXIT LOOP KEY SWITCH 6 7 8 9 10 11 Yellow 12 Red White Green Blue DOORKING 4602-010 Red White 1 2 3 4 5 Black Blue Red ON 9150-065-Q-3
Model 9150 1/2 HP 115 VAC / Convenience Open 50uf Capacitor Blue Motor Resistors 1 Ohm 1 Ohm Blue 30 Watt 1/2 HP Motor Red Red 30 Watt Ground Built-In Solenoid Lock White Black MOV Assembly White Chassis Ground 115 VAC Hot Neu Neu Hot Hot Brown Alarm Black DC Motor Reset White Red Red White Yellow Red/White Red/White Black Black White Batteries Neutral Power 12 V 3 Amp/Hr Battery DC Power 12 V 3 Amp/Hr Battery AC Power Convenience Outlets 1 2 3 PurpleKEY SWITCH 4 Green 5 6 7 8
Model 9150 1/2 HP 208 / 230 / 460 VAC Blue 208 VAC 50uf Capacitor Black To AC Power Switch Blue Brown Motor Resistors White To AC Power Switch 1 Ohm Black/White 1/2 HP Motor Red Red 30 Watt To AC Power Switch 1 Ohm Blue 30 Watt Ground Blue Black Brown Blue White Black Black/White 230 VAC Brown White To AC Power Switch Black/White Blue Black To AC Power Switch Built-In Solenoid Lock Step-Down Transformer To AC Power Switch Black White Brown White Chassis Ground Black/White
Model 9150 1/2 HP 208 / 230 / 460 VAC / Convenience Open Blue 208 VAC 50uf Capacitor Black To AC Power Switch Blue Brown Motor Resistors White To AC Power Switch 1 Ohm Black/White 1/2 HP Motor Red Red 30 Watt To AC Power Switch 1 Ohm Blue 30 Watt Ground Blue Black Brown Blue White Black Black/White 230 VAC Brown White To AC Power Switch Black/White Blue Black To AC Power Switch Built-In Solenoid Lock Step-Down Transformer To AC Power Switch Black White Brown White Chassis G
Model 9150 1 HP 115 VAC Orange Yellow Blue 1 Ohm 1 Ohm 30 Watt 30 Watt Motor Resistors 1 Ohm 1 Ohm Red Orange 1 HP Motor 65 Watt 65 Watt Red Blue Ground Yellow Built-In Solenoid Lock Orange White Black MOV Assembly White Chassis Ground 115 VAC Hot Neu Neu Hot Hot Brown Alarm Black Black Red White White Yellow White Reset Neutral Power AC Power Convenience Outlets 1 2 3 4 5 REVERSE LOOP EXIT LOOP KEY SWITCH 6 7 8 9 10 11 Yellow 12 Red White Green Orange DOORKING 4602-010
Model 9150 1 HP 115 VAC / Convenience Open Orange Yellow Blue 1 Ohm 1 Ohm 30 Watt 30 Watt Motor Resistors 1 Ohm 1 Ohm Red Orange 1 HP Motor 65 Watt 65 Watt Red Blue Ground Yellow Built-In Solenoid Lock Orange White Black MOV Assembly White Chassis Ground 115 VAC Hot Neu Neu Hot Hot Brown Alarm Black DC Motor Reset White Red Red White Yellow Red/White Red/White Black Black White Batteries Neutral Power 12 V 3 Amp/Hr Battery DC Power 12 V 3 Amp/Hr Battery AC Power Conveni
Model 9150 1 HP 208 / 230 / 460 VAC Orange Blue 208 VAC Yellow Black To AC Power Switch Blue 1 Ohm 1 Ohm 30 Watt 30 Watt Brown White To AC Power Switch Motor Resistors 1 Ohm 1 Ohm Red Orange 1 HP Motor Black/White To AC Power Switch 65 Watt Blue Black To AC Power Switch 65 Watt Red Blue Ground Yellow Orange Built-In Solenoid Lock 230 VAC White Blue Black/White Black Brown To AC Power Switch White Blue Black To AC Power Switch Black/White Step-Down Transformer Brown Bl
Model 9150 1 HP 208 / 230 / 460 VAC / Convenience Open Orange Blue 208 VAC Yellow Black To AC Power Switch Blue 1 Ohm 1 Ohm 30 Watt 30 Watt Brown White To AC Power Switch Motor Resistors 1 Ohm 1 Ohm Red Orange 1 HP Motor Black/White To AC Power Switch 65 Watt Blue Black To AC Power Switch 65 Watt Red Blue Ground Yellow Orange Built-In Solenoid Lock 230 VAC White Blue Black/White Black Brown To AC Power Switch White Blue Black To AC Power Switch Black/White Step-Down Tra
Installation/Owner’s Manual Series 9150 Vehicular Slide Gate Operator Use this manual for circuit board 4602-010 Revision A or higher. 9150-065-Q-3-11 Convenience Open Optional www.doorking.com DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 Copyright 2009 DoorKing, Inc. All rights reserved.