Manual

9100-065-Z-3-13
1
11.5”
12”
14.75”
24”
Gate Frame
1” Minimum
4” Minimum
Class of Operation UL 325 Class I, II, III, IV
Type of Gate Vehicular Slide Gates Only
Horsepower 1/2 HP
Voltage / Phase 115 VAC Single-Phase
Current 5.4 Amps @ 120V
Max Gate Weight (Installed level) 1000 Lbs.
Max Gate Length (Installed level) 30 Ft.
Drive Sprocket Size #40 Chain
Cycles Per Hour 60 Per Hour
Speed Approximately 1 Ft. per Second
Entrapment Protection Primary - Inherent entrapment sensing system (Type A)
Secondary - Provision for connection of a non-contact
sensor (Type B1) and/or a contact sensor
(Type B2).
SPECIFICATIONS
WARNING
MOVING GATE CAN CAUSE
Operate gate only when gate area is in sight
and free of people and obstructions.
Do not allow children to play in gate area
or operate gate.
Do not stand in gate path or walk through
path while gate is moving.
Read owner’s manual and safety instructions.
SERIOUS INJURY OR DEATH
CLASS
CERTIFIED TO
CAN/CSA C22.2 NO. 247
CONFORMS TO
ANSI/UL-325
VEHICULAR GATE OPERATOR
HP
53382
MODEL
SERIAL
VOLTS PHASE
AMPS 60 Hz
MAX GATE LOAD
DoorKing, Inc., Inglewood, CA
10.5”
Chain Height:
Idler wheels in
top position.
Use this manual for the Model 9100
operator with circuit board 4602-010
Rev A or higher ONLY.
Concrete
Pad
Concrete
Pad
DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons
of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is copyrighted, all rights
reserved. No portion of this manual may be copied, reproduced, translated, or reduced to any electronic medium without prior written consent from DoorKing, Inc.