Owner's manual

9050-065-M-3-11
28
DANGER
HIGH VOLTAGE!
5.1 Main Terminal Description
Low Voltage Common
Dry Relay Contact
Earth Ground
Circuit Board Power
Circuit Board Power
Motor
Motor
Built-In Solenoid
Lock Power
Full Open
Dry Relay Contact
Standard Reverse
When gate is closed, this input will open gate to full position.
When gate is open and auto close timer Switch 2
is turned ON, input will re-set and hold timer.
When gate is open and auto close timer Switch 2
is turned OFF, input will close gate.
When gate is closing, input will reverse gate.
When gate is open and auto close
timer Switch 2 is turned ON, input
will re-set and hold timer.
When gate is open and auto close
timer Switch 2 is turned OFF, input
will prevent gate from closing.
When gate is closing, input will reverse gate.
This input ONLY functions when gate is fully
open or in the closing cycle.
Operation of relay is dependent on setting of switch 3.
When Switch 3 is turned ON, relay activates
when gate is in the full open position.
When Switch 3 is turned OFF, relay is
activated when gate IS NOT closed.
Relay contacts can be set for Normally Open (NO) or
Normally Closed (NC) operation.
Contact rating is 1 amp maximum at 24-volts DC.
8
NC
NO
4702-010
12
11
10
9
8
7
6
6
5
4
3
2
1
9
10
11
NC
NO
SECTION 5 - MAIN TERMINAL WIRING
24 VAC - 250 mamp. max.
1
ON
2 3 4 5 6 7 8
1
ON
2 3 4 5 6 7 8
1
ON
2 3 4 5 6 7 8