Owner manual

1919
2.7 Primary / Secondary (Dual) Gate Connection
1
Motor
2
Motor
3
Neutral
4
Ground
5
Limit
6
Limit
7
COM
8
24VAC
1
Motor
2
Motor
3
Neutral
4
Ground
5
Limit
6
Limit
7
COM
8
24VAC
Conduit
Primary/secondary
interconnection cable
in underground conduit.
Power Conduit to
Primary Operator Only.
Primary/Secondary
Interconnection
Cable
Secondary Operator Terminal
Conduit
Primary Operator Second Terminal
Primary Operator
Secondary Operator
Primary Operator Control Board
Connect the Primary / Secondary interconnection wiring as shown. Wire colors are based on
DoorKing interconnection cable (P/N 2600-75x). Power is supplied to the secondary operator
by the interconnection cable.
Secondary operator contains NO control board.
All control, loop detector, safety and auxiliary
devices are wired to the primary operator.
Brown wire is not used.