Manual

6500-065-V-12-12
33
DC Motor Negative Output
DC Motor Positive Output
Battery Negative Input
Battery Positive Input
24 VAC Common
24 VAC Input
Activation Output
Radio Power Not used.
Open Input
Common Not used.
7.3 DIP-Switch Settings for 2340 Circuit Board
7.2 DC System Description
Switch Function Setting Description
Convenience
Open
Operation
Open Direction
Limit Sensor
Automatic
Power-up
Activation
OFF
ON
ON
OFF
Operator Type
Not Used
DO NOT use the OFF setting.
Do Not Adjust Do Not Adjust Timer Not Used Charging LED
Orange to Second Terminal #5
1
2
3
4
5-8
Gate will automatically open and remain open when a power outage occurs.
OFF setting connects to gate operator’s OPEN limit sensor upon loss of AC power
which is used to open gate.
OFF
OFF
DO NOT use the ON setting.
ON
ON
When AC power is restored, an input (push button, loop, radio receiver, connected
to the 4405 main circuit board) is required to return the gate to normal operation.
When AC power is restored, a 1-second pulse is sent to the gate operator input to
automatically close the gate and restore normal operation.
Must be in the ON position.
2340
DIP-Switches
Gate will automatically
OPEN and stay open during
an AC power failure.
DIP-Switch 3 setting will
determine how operator will
return to normal operation
AFTER AC power has been
restored.
+
12 V
3 Amp/Hr
+
12 V
3 Amp/Hr
Batteries
To Secondary Operator
DC ON/OFF
Power Switch
Red
Black
Red/White
Red/White
DC Motor
Black/White
Green not used.
Purple to Second Terminal #8
White to Second Terminal #7
Diode
Orange to P2 Plug on Circuit Board
To Primary or Single Operator
Green to Main Terminal #5
Purple to Main Terminal #3
White to Main Terminal #13
Typical DIP-Switch
Settings (Automatic)
1
ON
2 3 4 5 6 7 8
2
5
6
7
8