2.1 High Voltage Wire Run
The distance shown in the chart is measured in Feet from the operator to the power source. If power wiring is greater than the
maximum distance shown, it is recommended that a service feeder be installed. When large gauge wire is used, a separate
junction box must be installed for the operator connection. The wire table is based on stranded copper wire. The wire run
calculations are based on a power source with a 3% voltage drop on the power line, plus an additional 10% reduction in
distance to allow for other losses in the system.
“Optional” Heater Installation Note: When installing a heater, refer to the “high voltage AC power wire size
and distance limitations” table on the instruction sheet with the heater kit for AC power wire run limitations.
This table illustrates the high voltage AC power wire size and distance limitations for a single operator.
Reduce the wire distance in half for a primary/secondary dual gate operator application
Model
Type
Voltage
Required
Amps
Required
Wire Size / Max Distance in Feet
12 AWG 10 AWG 8 AWG 6 AWG
Never run low voltage rated wire insulation in the same conduit as high voltage rated wire insulation.
180
100
5.4
9.7
115
115
290
162
485
270
725
405
6500 1/2 HP
6500 1 HP
2.2 High Voltage Terminal Connection
• Route incoming high
voltage power through
conduit and into the
operator as shown.
• Be sure wiring is installed
in accordance with local
codes. Be sure to color
code all wiring.
• It is recommended that a
surge suppressor be
installed on the high
voltage power lines to help
protect the operator and
circuit board from surges
and power fluctuations.
• Secondary operator in a
dual operator application
gets AC power through the
8-wire interconnection
cable that connects the 2
operators together. See
next page.
DANGER
HIGH VOLTAGE!
DO NOT cycle the operator without the OPEN and CLOSE limit sensors in their specific
open and close positions.
The limit sensors or the AC power switch are the only ways to stop the operator
once an open cycle has started. This could cause damage to the gate and/or operator if the gate opens too far!
P
U
SH
T
O
O
P
E
RA
T
E
t
echnician
u
se
o
nly
High Voltage
AC Power Wire
High
Voltage
Conduit
“Optional” High Voltage Kit Installation Note: When installing a high voltage kit for 208/230/460/575 VAC input power,
refer to the “high voltage AC power wire size and distance limitations” table on the instruction sheet with the
high voltage kit (P/N 2600-266) for AC power wire run limitations.
Chassis
Ground
HotNeu
White - Neutral
Black - 115 VAC Hot
Green - Chassis Ground
Note: A separate
power disconnect
switch may be needed
in your area. Check
local building codes
before installation.
Note: “Optional”
High Voltage Kit
black and white wires
connect the same as
shown above.
High Voltage
AC Power Wire
External
Power
Disconnect
Switch
AC POWER
ON
OFF
115 VAC
AC Power Terminal