SECTION 1 - INSTALLATION
1.1 Underground Conduit Requirements
1.2 Concrete Pad
Sweeps
Concrete Pad
Primary
Operator
Position
Secondary
Operator
Position
Underground depth of the
concrete pad is determined
by soil conditions and local
building codes. Reinforced
concrete recommended.
22” Concrete Pad Width
28” Concrete Pad Length
Concrete pad
MUST be level.
Note: Bevel the
edges of concrete
pad to eliminate
water puddling
under the operator.
4” minimum
31”
7.5”
to
center
11”
21” to
center
of
conduit
area
Operator and Conduit Location
22”
Approximate
Conduit Position
CAUTION
NEVER REMOVE HUB
after manual release.
Back-up
Motor,
Step-Down
Transformer
Plate
AC Power, Reset Box
Center Line
Prior to beginning the installation of the swing gate operator, we suggest that you become familiar with the
instructions, illustrations, and wiring guide-lines in this manual. This will help insure that your installation is
performed in an efficient and professional manner compliant with UL 325 safety and ASTM F2200 construction
standards.
The proper installation of the vehicular swing gate operator is an extremely important and integral part of the
overall access control system.
Check all local building ordinances and building codes prior to installing
this operator. Be sure your installation is in compliance with local codes.
• The conduit requirements are for a typical slide gate operator installation (the secondary operator is shown for
those applications where a secondary operator may be used). The conduit requirements for your application may
vary from this depending on your specific needs.
• Use only sweeps for conduit bends. Do not use 90° elbows as this will make wire pulls very difficult and can cause
damage to wire insulation.
• DoorKing recommends using 3/4-inch conduit.
• Be sure that all conduits are installed in accordance with local codes.
• Never run low voltage rated wire insulation in the same conduit as high voltage rated wire insulation.
Elbow
NO
Sweep
YES
Control and/or P.A.M.S. Wires (Low Voltage wire insulation)
DoorKing’s Primary/Secondary Interconnection Cable (Dual Operator Application Only)
(Secondary Operator AC Power and Communication wires)
Loop Lead-In Wires (Low Voltage wire insulation)
AC Input Power (High Voltage wire insulation)
6.5”
3.5” 3.5”
6” x 10”
Conduit Area
6” x 10”
Conduit Area