Manual

2.5 Primary / Secondary (Dual) Gate Wiring
DOORKING, INC., INGLEWOOD, CA 90301
Title:
Date: Rev.Dwg. No.
Red
Brown
Orange
2
3
4
5
6
9/07
A
4502-DUAL-1
Model 6050, 6100 and 6300
Primary / Secondary Wiring Diagram
Secondary
Operator
1 2 3 4 5 6 7 8 9 1011121314
15
16 17 18 19 20
1
Connect the Primary / Secondary interconnection wiring as shown. Wire colors are based
on DoorKing interconnection cable (P/N 2600-75x).
Place a jumper from terminal 15 to terminal 16 in the PRIMARY operator.
Plug a two-channel (P/N 9409-010) loop detector into the REVERSE loop port in the
PRIMARY operator. Connect loops and loop detector as shown.
2
3
4
5
6
Connect chassis ground to chassis ground.
DoorKing
9410-010
TB1
Yellow
Blue
White
Conduit
Reverse
Reverse
Exit
Shadow
4502-010
Circuit Board
Primary
Operator
Auxiliary Terminals
1 2 3 4 5 6 7 8 9 10 11 12 13 14
15
16 17 18 19 20
12345678
Secondary
Motor
Red
White
Brown
Orange
Blue
Yellow
DoorKing
9409-010
TB1 TB2 TB3
A A
B
1
Place a jumper from terminal 19 to terminal 20 in the SECONDARY operator.
Plug a single channel (P/N 9410-010) loop detector into the EXIT loop port in the
PRIMARY operator. Connect loop and loop detector as shown.
A
Open direction non-contact sensor.
B
Close direction non-contact sensor.
Page 32 6300-065-E-4-08