Instruction Manual

6300-065-Z-7-12
26
5.1 Main Terminal Description
Low Voltage Common
Low Voltage Common
24 VDC Maglock Power
Dry Relay Contact
Dry Relay Contact
CLOSE - DoorKing 3-Button station ONLY
Open - DoorKing 3-Button station ONLY
Standard Reverse or Shadow
Full Open
Full Open
24 VAC - 250 ma. max.
12 VAC - 150 ma. max.
Pulse 1 - Primary Operator
Pulse 2 - Secondary Operator
Not Used
Motor
Motor
Circuit Board Power
Power - Neutral
Power - Neutral
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
NC
NO
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
DANGER
HIGH VOLTAGE!
SECTION 5 - CIRCUIT BOARD WIRING
lf SW 1, switch 3 is ON, functions as a
normal full open input (Normal setting).
lf SW 1, switch 3 is OFF, input to
terminal #4 becomes the output from the
EXIT loop detector plugged into the EXIT
loop port. (Used for specialized functions).
SW 1
1
ON
2 3 4 5 6 7 8
12
SW 1
1
ON
2 3 4 5 6 7 8
When gate is closed, input will open gate.
When gate is open and auto close timer
SW 1, switch 4 is turned ON, input will
re-set and hold timer.
When gate is open and auto close timer
SW 1, switch 4 is turned OFF, input will
close gate.
When gate is closing, input will reverse gate.
11
This input ONLY functions when gate is fully
opened or in the closing cycle.
When gate is closing: SW 2, switch 5 is OFF, an
input to terminal #15 (e.g.: photo beam gets
obstructed) will reverse and open the gate.
Note: If the auto-close timer is ON, when
gate reaches the open position, timer will
not close the gate. Another input
command is needed to reset and close
the gate.
When gate is closing: SW 2, switch 5 is
ON, an input to terminal #15 (e.g.: photo
beam gets obstructed) has NO effect on the
gate operator (Set for Shadow input).
SW 2
1
ON
2 3 4 5 6 7 8
15
Operation of the circuit board dry relay
contact is dependent on setting of SW 1,
switches 1 and 2.
Relay contacts can be set for Normally
Open (NO) or
Normally Closed (NC)
operation.
Contact rating is
1 amp maximum
at 24-volts DC.
NC
NO
SW 1
1
ON
2 3 4 5 6 7 8
16
24-volt DC magnetic lock
power is provided constantly
except when the gate is
opening or open (Normally
Closed function). 1 Amp Max.
18