User Manual

6003-065-Q-2-12
14
PRIMARY Actuator
Mounting Control Box Continued
Primary
Operator
Cable
Secondary Operator Conduit
Input Power
Conduit
Loops Conduit
Mounting Pole
Not Provided
Flexible Conduit
Junction
Boxes
Elbow
NO
Sweep
YES
Conduit
From Secondary Operator if Installed (See previous page)
Solar Control Box
Solar Cabinet
Mounting Holes
and Conduit
Holes
3/4” Conduit
Knockouts
Mounting
H
oles
Mounting Hole
3/4” Conduit
Knockouts
Antenna
Hole
Cabinet
Back
DoorKing offers a mounting
post kit (P/N 1000-045)
when no vertical surface is
available to mount the solar
control box cabinet to.
Cover
Mounting Post
Mount to
C
oncrete
To attach post to concrete,
DoorKing recommends four
(4) 3/8” x 3” sleeve anchors
(not supplied). Do Not mount
post on asphalt.
Cabinet
Back
Loops
Typical conduit
configuration
(not supplied).
Remove fragile
components
from control
box to protect
them during
installation if
necessary.
Low
Voltage
Primary Operator
Secondary Operator
Solar
Power
F
lexible
C
onduit
Low
Voltage
Low
Voltage
Low
Voltage
3/4” conduit
recommended.
Coaxial
Cable
Antenna
Kit
P/N
1514-073
(Sold
separately)
One 24 V 10 watt panel
required for 18 Amp/Hr
batteries. DO NOT USE
10 watt panel with the
35 Amp/Hr batteries.
One 24 V 20 watt panel
required for 35 Amp/Hr batteries.
DO NOT USE 20 watt panel with
the18 Amp/Hr batteries.
24 Volt 10 Watt
Solar Panel
P/N 2000-077
24 Volt 20 Watt
Solar Panel
P/N 2000-076
DO NOT use a 12 volt solar panel. Damage WILL occur!!
ONLY Mount One 24 Volt Solar Panel!
The 24 volt - 10 watt or 20 watt solar panel must be correctly
installed for the system to function correctly. See the solar control
box Wiring/Owner’s manual for more information about concerns,
considerations and recommendations for proper solar panel
positioning and mounting.