Instruction Manual

16
6002-065-M-6-08
12345
6
7
89
10 11 12
13
14 15
16 17 18 19
20
2.3 Main Terminal Description
24 VAC INPUT
24 VAC INPUT
24V COMMON
ALARM RESET
Not Used
12 VOLT BATTERY
Not Used
DC LOCK POWER COMMON
24 VDC Maglock POWER
DRY RELAY CONTACT
DRY RELAY CONTACT
24V COMMON
REVERSE INPUT/SHADOW INPUT
24V COMMON
OPEN INPUT
24V COMMON
SINGLE BUTTON ACTIVATION INPUT/
EXIT LOOP LOGIG OUTPUT
24V DC RADIO POWER ONLY
250 ma. maximum
RADIO RELAY -
SINGLE BUTTON ACTIVATION INPUT
24V COMMON
Operation of relay is dependent on setting of
SW 2, switches 1 and 2. Relay contacts can
be set for Normally Open (NO) or Normally
Closed (NC) operation. Contact rating is
1 amp maximum at 24 Volts.
1
ON
2 3 4
SW 2
Switch 1 OFF, Switch 2 OFF:
Relay activates when gate is OPEN.
Switch 1 OFF, Switch 2 ON:
Relay activates when gate is OPEN,
OPENING or CLOSING.
Switch 1 ON, Switch 2 OFF:
Relay activates when gate is OPEN or OPENING.
Switch 1 ON, Switch 2 ON:
Relay activates when gate is OPENING or CLOSING.
NO
NC
1
ON
2 3 4
SW 2
Maglock:
Switch 3 ON,
1 sec. delay
at start.
1
ON
2 3 4 5 6 7 8
SW 1
When gate is closed, input will open gate.
When gate is open and auto close
timer SW 1, switch 4 is turned ON,
input will re-set and hold timer.
When gate is open and auto close
timer SW 1, switch 4 is turned OFF,
input will close gate.
When gate is closing, input will
reverse gate.
lf SW 1, switch 3 is ON,
this input is identical to
Single Button Activation.
lf SW 1, switch 3 is OFF,
this terminal becomes the
logic output of the EXIT loop
detector.
1
ON
2 3 4 5 6 7 8
SW 1
When gate is closed, this input has no
affect on the gate operator.
When gate is open and auto close
timer SW 1, switch 4 is turned ON,
input will re-set and hold timer.
When gate is open and auto close
timer SW 1, switch 4 is turned OFF,
input will prevent gate from closing.
When gate is closing, input will
reverse gate if SW 1, switch 5 is OFF.
When gate is closing, input has no
affect on the gate operator if SW 1,
switch 5 is ON (set for shadow input).
1
ON
2 3 4 5 6 7 8
SW 1
1
ON
2 3 4 5 6 7 8
SW 1
4
8
2
15
12
10
11
DC power is not present on the board
until first initial cycle of gate.