User guide

4302-065-F-1-13
12
12345
6
7
89
10 11 12
13
14 15
16 17 18 19
20
1.4 Main Terminal Description
Operation of the relay is dependent on the setting
of SW 2, switches 1 and 2. Relay contact can be
set for Normally Open (NO) or Normally Closed
(NC) operation. Contact rating is 1 amp
maximum at 24 Volts.
SW 2, Switch 1 OFF, Switch 2 OFF:
Relay activates when gate is OPEN.
SW 2, Switch 1 OFF, Switch 2 ON:
Relay activates when gate is OPEN, OPENING or CLOSING.
SW 2, Switch 1 ON, Switch 2 OFF:
Relay activates when gate is OPEN or OPENING.
SW 2, Switch 1 ON, Switch 2 ON:
Relay activates when gate is OPENING or CLOSING.
NO
NC
Maglock: SW 2,
Switch 3 ON, 1 sec.
delay at start.
SW 1
When gate is closed, input will open gate.
When gate is open and auto close
timer SW 1, switch 4 is turned ON,
input will re-set and hold timer.
When gate is open and auto close
timer SW 1, switch 4 is turned OFF,
input will close gate.
When gate is closing, input will
reverse gate.
SW 1, switch 3 is ON, terminal #4
functions as a normal FULL open input
(Normal Setting).
SW 1, switch 3 is OFF, terminal #4
becomes the output from a plug-in loop
detector installed in the EXIT loop port
of the circuit board.
When gate is closed, this input has no
affect on the gate operator.
When gate is open and auto close
timer SW 1, switch 4 is turned ON,
input will re-set and hold timer.
When gate is open and auto close
timer SW 1, switch 4 is turned OFF,
input will prevent gate from closing.
When gate is closing, input will
reverse gate when SW 1, switch 5
is OFF.
SW 1, switch 5 ON is NOT used.
4
8
2
15
12
10
11
DC power is not present on the
board until first initial cycle of gate.
1
ON
2 3 4 5 6 7 8
SW 1
1
ON
2 3 4 5 6 7 8
SW 1
1
ON
2 3 4 5 6 7 8
SW 1
1
ON
2 3 4 5 6 7 8
SW 2
1
ON
2 3 4
SW 2
1
ON
2 3 4
Low Voltage Common
Low Voltage Common
For specific wiring information, see next page.
Low Voltage Common
Low Voltage Common
Dry Relay Contact
Alarm Reset
Dry Relay Contact
24 VDC - 250 ma max.
Full Open
Full Open
Full Open
Standard Reverse
Not Used
Not Used
DC Lock Power Common
24 VDC Maglock Power
12 Volt Battery
Low Voltage Common
24 VAC Input
24 VAC Input