ENTRACOMP® 26SA With Remote Open Input User/Installation Manual
COPYRIGHT © 2007 SOUNDCRAFT INC.
TABLE OF CONTENTS INTRODUCTION ............................................................................. 1 SETTING THE SYSTEM (FACILITY) CODE .................................. 3 PROGRAMMING THE ENTRACOMP® 26SA ................................ 5 VALIDATING A SINGLE CARD ................................... 5 VALIDATING A BLOCK OF CARDS ............................ 6 VOIDING CARDS ........................................................ 7 SETTING THE LATCH TIMER .......................................
FLUSH MOUNT TO EXISTING 5S BOX..................... FLUSH MOUNT WITH 5S BOX .................................. FLUSH MOUNT WITHOUT 5S BOX........................... METAL SURFACE HOUSING TO SINGLE GANG ELECTRICAL BOX ............................................... METAL SURFACE HOUSING WITHOUT ELECTRICAL BOX ............................................... METAL SURFACE HOUSING WITH POST ADAPTER ............................................................. METAL SURFACE HOUSING WITH FLANGE ADAPTER ..........
INTRODUCTION The ENTRACOMP® 26SA is a stand alone access control system that will control access to a passageway for up to 65,503 individuals. There are two kinds of cards used with the ENTRACOMP® 26SA, access cards and program cards. Access cards are used by individuals to gain access to the passageway. Each access card is magnetically encoded with two types of information: the system code (or facility code) and the ID number.
“0” “1” “2” “3” “4” “5” “6” “7” “8” “9” “VALID” “VOID” “ ” “SET TIMER” * “ACTIVE/INACTIVE” - ZERO ONE TWO THREE FOUR FIVE SIX SEVEN EIGHT NINE VALIDATE VOID OR CANCEL THRU SET LATCH TIMER OR ANTIPASSBACK TIMER ACTIVATE OR INACTIVATE SYSTEM Secura Key • 2
SETTING THE SYSTEM (FACILITY) CODE When received, the correct system code may already be set. Should it become necessary to reset the system code, remove the unit from the wall to gain access to the reset button (see figure 1). Momentarily depress the reset button. The LED indicator will flash red and green alternately (If at power up, the LED is already flashing red/green, it is not necessary to remove the unit from the wall and press the reset button).
FIGURE 1 Secura Key • 4
PROGRAMMING THE ENTRACOMP® 26SA Functions of the ENTRACOMP® 26SA are programmed by placing the program cards on the TOUCH CARD® reader plate in a proper sequence. It is helpful to think of placing a program card on the TOUCH CARD® reader plate as depressing a key on a keyboard or key pad. You may begin programming at any time by placing the first program card of the sequence on the TOUCH CARD® reader plate. At this point the LED indicator will show an amber color.
Example: Validate card number 100. Place the “1” card on the TOUCH CARD® reader plate, remove it and place the “0” card on the TOUCH CARD® reader plate, remove it and place again the “0” card on the TOUCH CARD® reader plate, remove it and place the “VALID” card on the TOUCH CARD® reader plate, and remove it. 1 + 0 + 0 + VALID VALIDATING A BLOCK OF CARDS.
VOIDING CARDS. Cards may also be voided (cancelled) either singly or in blocks. Follow the instructions for validating above, replacing the “VALID” card with the “VOID” card. SETTING THE LATCH TIMER. The output from the relay may be set to any number of seconds from 1 to 99. To set the latch timer, place on the TOUCH CARD® reader plate the sequence of program cards representing the number of seconds the latch is to be on, then place the “SET TIMER” card on the TOUCH CARD® reader plate and remove it.
DOOR UNLOCK MODE. The relay may be set to stay latched (door unlocked) during periods when access control is unwanted. While in the “DOOR UNLOCK” mode, the relay stays activated, and the LED indicator will flash green approximately once every second. The unit may not be programmed with the programming deck, nor will it recognize access cards while in the “DOOR UNLOCK” mode.
To deactivate the Timed Antipassback feature, place the “0” card on the TOUCH CARD® reader plate and remove it. Then place the “*” card on the TOUCH CARD® reader place and remove it. Then place the “SET TIMER” card on the TOUCH CARD® reader plate and remove it. 0 + * + SET TIMER ANTIPASSBACK WAITING TIME. The antipassback waiting time may be set to any number of minutes from 1 to 99. However, the actual waiting time will fluctuate between the time set and twice the time set.
RELAY CONFIGURATION. The solid-state relay can be set to be Normally Closed, Normally Open or to operate with the SecuRelayTM for increased vandal resistance. Selections are: 6. Normally Open (Factory default) 7. Normally Closed 8. SecuRelay™ Option. The default mode is Normally Open (NO). To place the relay in the Normally Open (NO) mode, place the “ ” card on the reader twice, followed by the “6” card.
INSTALLATION WIRING INSTRUCTIONS The ENTRACOMP® 26SA is provided with a connector and 7 wire leads (See Figure 1). Using appropriate wire nuts or crimp on connectors, wire the unit as per the table below. Be sure unused wires are insulated to avoid shorting. In addition to the wiring below, AN EARTH GROUND IS REQUIRED. It must be connected to the green screw on the mounting bracket .
2%02/'2!- 2%,!9 &/2 .# &/2 -!'.
3%% 4!",% &/2 7)2).' 2%-!).).' 2%!$%2 7)2%3 .
REMOTE OPEN (REX). Connect the Brown and orange wires to any Normally Open switch. Closing this circuit will activate the Latch Relay for the number of seconds you have selected when you set the Latch Timer. SecuRelayTM. The SecuRelayTM from Secura Key may be purchased separately for use with ENTRACOMP ® 26SA units which have firmware version 4.0 or later.
INSTALLATION INSTRUCTIONS SURFACE HOUSING TO SINGLE GANG ELECTRICAL BOX (See Figure 4) 1. For exterior walls, apply 1/4 inch bead of silicone sealant around rear perimeter surface of mounting bracket gasket. Be sure there is sufficient sealant to make a good seal between gasket and wall. 2. Use two 6-32 x 1 pan head screws provided to secure mounting plate to box. 3. Connect power and control lines to wire leads provided as per the wiring instructions. 4. Plug connector into reader board. 5.
2. Mount plate to wall using appropriate fasteners. Use at least four of six holes provided. 3. Connect power and control lines to wire leads provided as per the wiring instructions. 4. Plug connector into reader board. 5. Place ENTRACOMP® 26SA housing against mounting plate, top edge first, centering housing on retaining tabs. Secure housing to plate at bottom using one 6-32 x 3/8 security screw provided or equivalent. 6. Lock cam lock. SURFACE HOUSING WITH POST MOUNT ADAPTER (See Figure 6) 1.
4. Connect power and control lines to wire leads provided as per the wiring instructions. 5. Plug connector into reader board. 6. Place ENTRACOMP® 26SA housing against mounting plate, top edge first, centering housing on retaining tabs. Secure housing to plate at bottom using one 6-32 x 3/8 security screw provided or equivalent. 7. Lock cam lock. SURFACE HOUSING WITH FLANGE MOUNT ADAPTER (See Figure 7) 1. Position flange mount adapter (optional) against post flange (not supplied).
FIGURE 4 FIGURE 5 Secura Key • 18
FIGURE 6 FIGURE 7 Secura Key • 19
FLUSH MOUNT TO EXISTING 5S BOX (See Figure 8) 1. Use wall cutout template provided. Align template over 5S box. (When running wires to the 5S box, don’t use center top hole as it will interfere with housing lock.) Transfer appropriate cutout corner locations of clearance hole for the housing lock to the wall with pointed instrument. 2. Draw lines from point to point, outlining cutout. 3. Cut out opening, being careful not to make opening larger than indicated on the template. 4.
FLUSH MOUNT WITH 5S BOX (See Figure 9) 1. Use the wall cutout template provided. Locate template on the wall. Transfer appropriate cutout corner locations to the wall with a pointed instrument. 2. Draw lines from point to point, outlining cutout. 3. Cut out opening, being careful not to make opening larger than indicated on the template. 4. Place mounting plate against wall in its proper location. Using it as a template, mark four holes in corners.
8. Place reader and faceplate assembly against the mounting plate. Faceplate will hook onto mounting plate by pushing plate in and then sliding it down. 9. Secure faceplate to mounting plate using the two 4-40 screws. 10. Place faceplate door into door opening and rotate key 90° clockwise. FLUSH MOUNT WITHOUT 5S BOX (See Figure 10) 1. Use the wall cutout template provided. Locate template on the wall. Transfer appropriate cutout corner locations to the wall with a pointed instrument. 2.
6. Be sure all appropriate wiring has been connected to the terminal board and then plug the terminal board cable into the socket on the circuit board (see wiring instructions). 7. Place reader and faceplate assembly against the mounting plate. Faceplate will hook onto mounting plate by pushing plate in and then sliding it down. 8. Secure faceplate to mounting plate using the two 4-40 screws. 9. Place faceplate door into door opening and rotate key 90° clockwise.
FIGURE 9 FIGURE 10 Secura Key • 24
METAL SURFACE HOUSING TO SINGLE GANG ELECTRICAL BOX (Figure 11) 1. For exterior walls, apply 1/4 inch bead of silicone sealant around rear perimeter surface of mounting bracket gasket. Be sure there is sufficient sealant to make a good seal between gasket and wall. 2. Use two 6-32 x 1 pan head screws provided to secure mounting bracket and gasket to box. 3. Connect power and control lines to wire leads provided as per the wiring instructions. 4. Plug connector into reader board. 5.
2. Mount plate to wall using appropriate fasteners. Use at least four of six holes provided. 3. Connect power and control lines to wire leads provided as per the wiring instructions. 4. Plug connector into reader board. 5. Place ENTRACOMP® 26SA housing over mounting bracket. Push housing in against wall. Secure housing to mounting bracket in door opening using two 6-32 x 3/8 screws provided. Secure housing to bracket at bottom using one 6-32 x 1/4 security screw provided or equivalent. 6.
4. Connect power and control lines to wire leads provided as per the wiring instructions. 5. Plug connector into reader board. 6. Place ENTRACOMP® 26SA housing over mounting bracket. Push housing in against wall. Secure housing to mounting bracket in door opening using two 6-32 x 3/8 screws provided. Secure housing to bracket at bottom using one 6-32 x 1/4 security screw provided or equivalent. 7. Place housing door into door opening and rotate key 90 degrees clockwise.
FIGURE 11 FIGURE 12 Secura Key • 28
FIGURE 13 FIGURE 14 Secura Key • 29
SPECIFICATIONS PHYSICAL Surface Housing Flush Housing Depth 2.25 in (5.72 cm) 1.50 in (3.8 cm) Width 4.00 in (10.16 cm) 5.50 in (13.97 cm) Height 4.60 in (11.70 cm) 7.63 in (19.38 cm) Weight 20 oz (0.57 kg) 18 oz (0.51 kg) Material Lexan7 (Polycarbonate) meets UL standard 94 flame retardant rating Metal Housing 1.75 in (4.45 cm) 4.00 in (10.20 cm) 5.62 in (14.30 cm) 45 oz (1.
WARRANTY (U.S. and Canadian) “Secura Key products are warranted against defects in materials and workmanship for a period of 2 years from the date of purchase. Secura Key will replace any Secura Key manufactured product, except cards or tags, returned to us freight prepaid within the warranty period. This warranty does not include freight, taxes, duties, or installation expenses. THE WARRANTY SET FORTH ABOVE IS EXCLUSIVE AND NO OTHER WARRANTY, WHETHER WRITTEN OR ORAL, IS EXPRESSED OR IMPLIED.