User guide
1150-065-F-1-11
20
3.3 Limit Switch Adjustments
CLOSE
OPEN
Push and Hold Tab
Open
Limit
Nut
Close
Limit
Nut
Close Limit LED
Open Limit LED
• Turn power off.
• Push and hold locking plate tab.
• Adjust limit nuts at full open and
full close gate positions.
• Release locking plate tab to secure limit nuts.
• Turn power on. Cycle gate and check positions.
• Re-adjust if necessary.
• Start-up direction should be ON.
SW 1, switch 1.
• Auto close timer (when turned
on) SW 1, switch 2.
• SW 1, switch 3 should be ON.
• SW 2, switch 3 should be ON.
Adjust from 1 second (full counter
clockwise) to approximately 23
seconds (full clockwise).
1
ON
2 3
4 5 6 7 8
SW 1
123
Setting Timer
Basic DIP Settings
1
ON
2
3
4
SW 2
PUSH TO OPERATE
technician use only
LIMIT
LIMIT
PA RT
TIME
DELAY
REV SENSE
CLOSE
REV SENSE
OPEN
1
ON
2 3 41
ON
2 3 4 5 6 7 8
NO NC
EXIT
LOOP
REVERSE
LOOP
GATE FORCED