User guide

1150-065-F-1-11
20
3.3 Limit Switch Adjustments
CLOSE
OPEN
Push and Hold Tab
Open
Limit
Nut
Close
Limit
Nut
Close Limit LED
Open Limit LED
Turn power off.
Push and hold locking plate tab.
Adjust limit nuts at full open and
full close gate positions.
Release locking plate tab to secure limit nuts.
Turn power on. Cycle gate and check positions.
Re-adjust if necessary.
Start-up direction should be ON.
SW 1, switch 1.
Auto close timer (when turned
on) SW 1, switch 2.
SW 1, switch 3 should be ON.
SW 2, switch 3 should be ON.
Adjust from 1 second (full counter
clockwise) to approximately 23
seconds (full clockwise).
1
ON
2 3
4 5 6 7 8
SW 1
123
Setting Timer
Basic DIP Settings
1
ON
2
3
4
SW 2
PUSH TO OPERATE
technician use only
LIMIT
LIMIT
PA RT
TIME
DELAY
REV SENSE
CLOSE
REV SENSE
OPEN
1
ON
2 3 41
ON
2 3 4 5 6 7 8
NO NC
EXIT
LOOP
REVERSE
LOOP
GATE FORCED