Instruction Manual
Page 4
June, 2004
750 Operator And
455 D Control Panel Installation Manual
TECHNICAL DATA
T
HE 750 OPERATOR
Description 750 Standard 750 Long Leaf
Ambient temperature, deg F (deg C) -13 to 158 (-25 to 70)
Maximum duty cycle 30 Cycles/ Hour
Thermal cut out, deg F (deg C) 212 (100)
Power voltage required, VAC 115 ±10% or 230, +6 or -10%, 60 Hz
Absorbed power, W 220
Motor speed, rpm 1400
Type of oil FAAC HD (Aeroshell 41)
Hydraulic Power Unit:
Height × width × depth, in. (cm) 13
3/4 × 83/16 × 51/8 (35 × 20.8 × 13)
Weight, lb (kg) 20 (9)
Oil quantity, qt (l) 1 (0.9)
Hydraulic locking:
CBA: Opened
CBC: Closed
CBAC: Opened
and Closed
Not available
Gate weight, lb (kg) 1760 (800)
Maximum gate length, ft (m) 7 (2.1) 13 (4)
Hydraulic Drive Unit:
Height (not including shaft) ×
length × width, in. (cm)
4
7
/8 × 153/4 × 7
7
/8 (12.4 × 40 × 20)
Weight
100-deg swing, lb (kg)
180-deg swing, lb (kg)
18 (8)
20 (9)
Oil quantity, qt (l) 0.9 (1)
Maximum angle of rotation
100-deg swing, deg
180-deg swing, deg
118
200
90-deg opening time, sec
Nominal torque, ft-lb (Nm) 338 (460)
12