Manual

3
10
ENGLISH
The 615BPR automated system consists of an aluminium
beam with reflex reflectors, and a steel upright subjected
to cataphoresis treatment and painted with polyester paint.
The upright houses the hydraulic operator and the electronic
control unit.
The operator, which moves the beam, consists of a hydraulic
power pack and a double-acting cylinder.
The system is supplied with an adjustable torque limitation
system. It also includes a device stopping the beam in any
position, and a handy manual release command for use in
case of power cuts or faults.
The beam and the relevant balancing spring must be ordered
by referring to the sales price list.
The 615BPR automated system was designed and built
for controlling vehicle access. Do not use for any other
purpose.
The curve makes it possible to establish maximum work time (T)
according to use frequency (F).
E.g. The 615 BPR automated system can operate non-stop at a use
frequency of 50%.
To ensure efficient operation, operate in the work range under the
curve.
Important: The curve is obtained at a temperature of 20 °C. Exposure
to the direct sun rays can reduce use frequency down to 20%.
Calculation of use frequency
The percentage of effective work time (opening + closing) compared
to total time of cycle (opening + closing + pause times).
Calculation formula:
where:
Ta = opening time
Tc = closing time
Tp = pause time
Ti = interval time between
one complete cycle and
another.
foundation plate
barrier upright
control board
emergency release
torque adjustment screws
double acting piston
travel limit screw
M12 nut blocking the tie rod
rocker
oil filling plug
breather screw
balancing spring
spring adjustment tie-rod
hydraulic power pack
travel limit sensors
travel limit magnets
Ta + Tc
%F =
X 100
Ta + Tc + Tp + Ti
1.1 MAXIMUM USE CURVE
1 DESCRIPTION AND TECHNICAL SPECIFICATIONS
Tab. 1 - Technical specifications “Barrier 615BPR"
BARRIER MODEL
615BPR STD
615BPR RAP
Beam max. length (m)
5 2,5
Max. opening time (sec) 5,7 2,9
Angular speed (rad/sec)
0.28 0,54
Pump flow-rate (l/min)
1.5 3
Max. torque (Nm) 400 300
Types of beam
Rectangular / Rectangular
skirt articulated / Round
Use frequency (at 20°C)
50% 40%
Max. consecutive cycles (at 20°C)
220 340
Power supply 230V~ (+6 -10 %) 50Hz
Absorbed power (W) 220
Type of oil FAAC HP OIL
Oil quantity (Kg) 0,9
Thermal protection for winding
120° C
Torque adjustment system standard by-pass valves
Operating ambient temperature -40 ÷ +55 °C
Hood protective treatment cataphoresis
Hood paint Polyester RAL 2004
Protection class IP 44
Weight (Kg) 34
Upright dimensions LxHxP(mm) 270 x 1015 x 140
Electric motor technical specifications
RPM
1400 2800
Power (W) 220
Absorbed current (A) 1
Power supply 230V~ (+6 -10 %) 50Hz
AUTOMATED SYSTEM 615BPR
Fig. 1
Fig. 2
Operator 615BPR
Photocells
Key-operated push-button
Flashing lamp
Receiver
Loop Detector
1) To lay cables, use adequate rigid and/or flexible
tubes
2) Always separate connection cables of low voltage
accessories from those operating at 230v~. To prevent
any interference whatever, use separate sheaths.
2. ELECTRIC PREPARATIONS (standard system)
3 DIMENSIONS
Dimensions are in mm.
Fig. 3