Parameter
620
640
Express
Available beam length, ft (m) 8 (2.5) 10 (3) 13 (4)
16 (5) 20 (6)
10 (3) 13 (4) 16 (5)
18 (5.5) 23 (7)
13 (4) 16 (5)
20 (6)
Maximum beam length, ft
(m)
1
Wood
Aluminum
13 (4)
12 (3)
16 (5)
13 (4)
16 (5)
16 (5)
18 (5.5)
20 (6)
20 (6)
23 (7)
Articulated beam
(aluminum only)
10 (3) 13 (4) NA
NA NA
Skirted beam
(aluminum only)
NA NA 16 (5)
20 (6) 23 (7)
Pump capacity, liters 2 1.5 2
1.5 1
Motor speed, rpm 2800
2 1400
Opening time, sec (not
including braking)
2 3 4
5.5 8
Motor run time
2
(frequency of
use), %
100 100
Power voltage required, VAC
(frequency, Hz)
3
230/115 +6 or -10% (50–60)3
Power consumption, W 440
Operator cabinet weight, lb
(kg)
161 (73) 185 (84)
Operator cabinet dimensions,
in. (cm)
6-5/8 ´ 13-3/4 ´ 42-1/2
(17 ´ 35 ´ 108)
7-7/8 ´ 14-15/16 ´ 42-1/2
(20 ´ 38 ´ 108)
Type of oil Lubrication Engineers- MONOLEC 6115
Oil quantity, qt (l) 2.1 (2)
Fan Standard Standard
Automatic fan operation
temperature, deg F (deg C)
113 (45) 113 (45)
Automatic motor shut off
temperature, deg F (deg C)
185 (85) 185 (85)
Thermal overload switch, deg
F (deg C)
212 (100)
1 Measurements in feet are rounded; measurements in meters are precise.
2 The model 620 115VAC is not available with a 2800 rpm motor.
3 Your standard 220 VAC/115VAC power source meets the specification for 230 VAC, +6 or -10%