620/640 Operator And
624BLD Control Panel Installation Manual
THE 624 BLD CONTROL PANEL INSTALLATION INSTRUCTIONS
1ST LEVEL PROGRAMMING continued
DISPLAY FUNCTION DEFAULT
AUTOMATED SYSTEM STATUS:
Exit from programming, storage
of set data and return to
automated system status view.
CLOSED
OPENING PRE-FLASHING
OPENING
OPEN
ON PAUSE
CLOSING PRE-FLASHING
CLOSING
STOPPED READY TO
CLOSE
STOPPED READY TO
OPEN
EMERGENCY OPENING
CLOSING SAFETY DEVICE
IN OPERATION
1ST LEVEL PROGRAMMING continued
DISPLAY FUNCTION DEFAULT
LOOP 1:
If this function is activated, the
loop connected to the Loop1
input will have the OPEN
function.
= loop1 active
= loop1 not active
ATTENTION: If the function is
not activated, loop1 status will
nevertheless be available on one
of the outputs, if appropriately
set (see 2nd level programming).
LOOP 2:
If you activate this function, the
loop connected to Loop 2 input
will have the REVERSE/CLOSE
function, i.e. it will operate as
REVERSING during the closing
stage, and will activate a CLOSE
to the board at release.
= loop 2 active
= loop 2 not active
ATTENTION: If the function is
not activated, loop2 status will
nevertheless be available on one
of the outputs, if appropriately
set.
NO EFFECT
NO EFFECT