User Manual
Page 9
May, 2006
415 L LS Operator And
455 D Control Panel Installation Manual
Figure 9. Important mounting
dimensions for inward-swinging
Mounting Dimensions
90-deg Swing 110-deg Swing
A 7 5/8in. (195 mm) 6 5/8 in. (170 mm)
B 7 5/8 in. (195 mm) 6 5/8 in. (170 mm)
C 37 1/8 in. (943 mm)
D N/A N/A
E Less Than A
Figure 10. Important mounting
dimensions for outward-
swinging 415 L LS operators,
top view
Mounting Dimensions
90-deg Swing 110-deg Swing
A 7 5/8 in. (195 mm) 6 5/8 in. (170 mm)
B 7 5/8 in. (195 mm) 6 5/8 in. (170 mm)
C 50 3/4 in. (1290 mm)
D Maximum 5 in. (125 mm) 4 2/5 in. (110 mm)
E Less Than A
Less Than A
ATTACH THE OPERATOR TO THE REAR
M
OUNTING BRACKET
Attach the rear fork to the 415 L LS operator with the
long steel pin and two āCā clips
Attach the operator to the rear mounting bracket with
the short brass bolt and self locking nut.
ATTACH THE OPERATOR TO THE FRONT
M
OUNTING BRACKET
Attach the operator to the front mounting bracket with
the short pin and one snap ring on the bottom and one
snap ring on the top.