3. Turn the manual release knob clockwise 1/2 turn.
4. To re-engage the operator, perform the procedure
in reverse.
Now the 415 L LS Operator is manual released. You can
move the gate freely.
ATTACH THE ELECTRIC CABLES
Before mounting the operator to the gate panel you
must attach the two provided electric cables. See figure
3 & 4 for the detail sticker on the bottom of the
operator.
After attaching the electric cables to the 415 L LS
Operator, you will need to thread the cables thru the
assembled cable/strain relief cover and tighten the
strain relief as shown in figure 5.
Slide the cable/strain relief cover up the cables until
flush with the 415 L LS Operator and secure the cover
with the four (4) screws provided as shown in figure 6.
I
NSTALLING THE OPERATOR
Once you have prepared the gate, you are ready to
proceed with the installation of the operator.
Follow the instructions below to install your operator
whether in an inward or outward swinging
configuration.
Installing the operator consists of the following steps:
Attaching the rear mounting bracket
Attaching the operator to the rear mounting bracket
Attaching the front mounting bracket to the
operator
Attaching the front mounting bracket to the gate
leaf
Installing the 455 D control panel
Setting the operating controls
Figure 6. Attach the electric cable cover with
two screws provided
Figure 2. Use the Manual Release key to disengage the
415 Operator from its motor so that you can move the
gate leaf open and/or closed by hand.
Sticker Labeled Color Description
COM White Common Wire
FCC Red Closing Limit
FCA Black Opening Limit
OPERATOR MOTOR CABLE
Sticker Labeled Color Description
M White Common Wire
M Black Motor Directional
LIMIT SWITCH CABLE
M Red Motor Directional
M Yellow/Green
(Green)
Earth Ground Only
Figure 5. Assembling
the strain reliefs to the
cable cover
1
2
3
Figure 3. Electric Cable Detail Sticker
Figure 4. Electric Cable Wire Color Codes