User's Manual
ITA ENG FRA ESP DEU POR
5 / 8
6-1620135 rev.1 08/07/2015
5.2 Learning of the TCOO900 on the second relay of the RCOO900
3
4
6
Release the key on the TCOO900.
RCOO900 emits 2 BIP. (*)
The learning ended correctly.
1
Check that the DIP 4 and 5 of the TCOO900
and DIP 3 e 4 of the RCOO900 are set in the
same way.
Press and keep pressed the key on the
TCOO900 relative to the used input.
5
Number of BIP
Meaning
2 Transmitter correctly memorized
4 Fault: the maximum number of safety edges for selected channel has been
reached
1 Maximum time expired for the memorization of the transmitter (10 second)
Acoustic signalling during the learning phase
5.3 Summary of the acoustic signalling during the learning phase
2
2
RCOO900 emits 1 BIP.
3
4
Press and keep pressed the key on the
RCOO900.
Release the key on the RCOO900.
RCOO900 emits 2 BIP. (*)
1
5. LEARNING
5.1 Learning of the TCOO900 on the first relay of the RCOO900
Check that the DIP 4 and 5 of the TCOO900
and DIP 3 e 4 of the RCOO900 are set in the
same way.
Press and keep pressed the key on the
TCOO900 relative to the used input.
Release the key on the TCOO900.
5
The learning ended correctly.
For the successive learning, repeat the operation from point 1.
Press and keep pressed the key on the
RCOO900.
DO NOT RELEASE the key on the RCOO900.
Release the key on the RCOO900.
RCOO900 emits 1 BIP.
RCOO900 emits 2 BIP.
NOTE: when the TCOO900 is used with two connected safety edges, it is necessary to carry out the learning two times, one for each input.
WARNING: the same input of the TCOO900 can be memorized on both the relay. To erase the memorized input it is
necessary to carry out a complete reset of the RCOO900 (see paragraph 9).
(*) In case in which 4 BIP are reproduced, it means that the maximum number of safety edges for the selected channel has been reached and that no
new devices on the same relay can be memorized.
For the successive learning, repeat the operation from point 1.
NOTE: when the TCOO900 is used with two connected safety edges, it is necessary to carry out the learning two times, one for each input.
WARNING: the same input of the TCOO900 can be memorized on both the relay. To erase the memorized input it is
necessary to carry out a complete reset of the RCOO900 (see paragraph 9).
(*) In case in which 4 BIP are reproduced, it means that the maximum number of safety edges for the selected channel has been reached and that no
new devices on the same relay can be memorized.