4.0 Description
The 2ch DOLPHIN KEYPAD is a 2-channel radio keypad operating at 433,92 Mhz in AM/ASK
modulation.
It’s fully compatible with any receiver of the range ERONE
The RF signal is generated dialing a valid 4 or 5-digits code and then pushing the keys * or #
The internal memory can store 1 Master code and up to 22 User codes.
Each code is composed by 4 or 5 digits
The Master code allows managing the single user codes (memorize and delete)
The Default master code is 12345.
With the Master password [ 12345] doesn’t occur any RF transmission;
The keypad is only 2-channels [* or # ];
The system analyses any code sequence and keeps valid the last 4 or 5 digits typed before the *
or #.
If they bring a valid code the transmission is effected otherwise if the code dialed before pushing *
or # is wrong there is a long beep [beeeeeeep];
If the combination is valid after the key * or # activation, there is a “beep” and the led under key
N°5
starts blinking (slow) and all the rest of the led of the keypad switch off. The led 5 keeps on blinking
as long as the key * or # is pressed;
A timeout of 25 sec. limits the duration of the transmission;
Code combinations shorter than 5 digits are not accepted;
After the activation of any key there is a timeout of 3 sec. after which the combination is discarded
and must start again;
The 4 blue led of the keypad are normally off. After the pressure of any key, all the led switch on;
If no keys are activated the led switch off after 3 sec.;
By dialing 2 times the Master password ( 12345, 12345) you enter in a menu: all the led switch
OFF and the led 5 switch ON. From that menu are possible many functions.
*+X : means the button A followed by another button among : 0, 1, 4 ,5 and 6.
If, after the dialing of the 2 Master password, no buttons are pressed within 10 sec., the keypad
comes back to the normal mode.
If you want to exit from the menu before the 10 sec. it is enough to press the button #.
When the keypad is waiting for a code (as for the master password change or a new user code)
the led 5 keeps on blinking. If no code is dialed within 10 sec the keypad comes back to normal
mode.
Battery low
When the value of the battery voltage is drops under 3V, at the first access to the keypad, the all
led make 7 fast flashes before to get stable on
4.1 Buzzer ON/OFF
It is possible to put the buzzer ON or OFF ( in toggle way )
Master pwd, Master pwd, *,6, (beep) : set the buzzer ON if currently OFF
Master pwd, Master pwd, *,6, (beep) : set the buzzer OFF if currently ON